Computing effective doses to pediatric patients undergoing body CT examinations

被引:21
作者
Huda, Walter [2 ]
Ogden, Kent M. [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
[2] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
基金
美国国家卫生研究院;
关键词
effective dose; CT; pediatric dose;
D O I
10.1007/s00247-007-0732-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background The computation of patient effective doses to children is of particular interest given the relatively high doses received from this imaging modality, as well as the increased utilization of CT in all areas of medicine. Current methods for computing effective doses to children are relatively complex, and it would be useful to develop a simple method of computing pediatric effective doses for clinical purposes that could be used by radiologists and technologists. Objective To obtain pediatric effective doses for body CT examinations by the use of adult effective doses obtained from effective dose (E) per unit dose length product (DLP) coefficients, and energy imparted to a child relative to an adult. Materials and methods Adult E/DLP coefficients were obtained at 120 kV using the ImPACT CT dosimetry spreadsheet. Patients were modeled as cylinders of water, and values of energy imparted to cylinders of varying radii were generated using Monte Carlo modeling. The amounts of energy imparted to the chest and abdomen of children relative to adults (R-en) were obtained. Pediatric effective doses were obtained using scaling factors that accounted for scan length, mAs, patient weight, and relative energy imparted (R-en). Results E/DLP values were about 16 mu Sv/mGy cm for males and about 19 mu Sv/mGy cm for females. R-en at 120 kV for newborns was 0.35 for the chest and 0.49 for the abdomen. At constant mAs, the effective dose to 6-month-old patients undergoing chest CT examinations was found to be about 50% higher than that to adults, and for abdominal examinations about 100% higher. Conclusion Adult effective doses can be obtained using DLP data and can be scaled to provide corresponding pediatric effective doses from body examinations on the same CT scanner.
引用
收藏
页码:415 / 423
页数:9
相关论文
共 50 条
[31]   Effective doses and risks from medical diagnostic x-ray examinations for male and female patients from childhood to old age [J].
Harrison, John D. ;
Haylock, Richard G. E. ;
Jansen, Jan T. M. ;
Zhang, Wei ;
Wakeford, Richard .
JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)
[32]   DOSE ESTIMATION IN RADIOLOGY - EFFECTIVE DOSES FOR THE MOST FREQUENT ROENTGEN EXAMINATIONS [J].
KESKE, U ;
HIERHOLZER, J ;
NEUMANN, K ;
CORDES, M ;
VENZ, S ;
AMTHAUER, H ;
MATSCHKE, S ;
FELIX, R .
RADIOLOGE, 1995, 35 (03) :162-170
[33]   Assessment of organ and effective doses received by adult patients undergoing computed tomography in three hospitals in Brazzaville, Congo Republic [J].
Bazoma, J. ;
Dallou, G. B. ;
Meye, P. Ondo ;
Biona, C. Bouka ;
Saidou ;
Ben-Bolie, G. H. .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (04) :379-386
[34]   Estimation of Effective Doses and Lifetime Risk of Exposure-induced Cancer Death in Pediatric CT Scans [J].
Razavi, Elham ;
Zare, Mohammad Hossein ;
Zamani, Hamed ;
Dalvand, Saman ;
Masjedi, Hamidreza ;
Omidi, Reza ;
Razavi-Ratki, Seid Kazem ;
Hazbavi, Maryam .
INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2022, 10 (04) :15755-15771
[35]   DOSES TO ADULT PATIENTS FROM COMPUTED TOMOGRAPHY EXAMINATIONS [J].
Domienik, Joanna ;
Zmyslony, Marek .
MEDYCYNA PRACY, 2012, 63 (06) :629-635
[36]   The effective and collective dose to patients undergoing abdominopelvic and trunk computed tomography examinations: A Belgian multicentre study [J].
De Roo, Bieke ;
Stichelbaut, Nele ;
Hoste, Pieter ;
Verstraete, Koenraad ;
Bacher, Klaus .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 111 :81-87
[37]   A survey of the pediatric radiation doses during multiphase abdominal computed tomography examinations [J].
Sulieman, A. ;
Adam, H. ;
Tamam, N. ;
Alkhorayef, M. ;
Alhailiy, A. ;
Alghamdi, S. ;
Elnour, A. ;
Alomair, O. ;
Alashban, Y. ;
Khandaker, M. U. ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 188
[38]   Estimating Effective Dose to Pediatric Patients Undergoing Interventional Radiology Procedures Using Anthropomorphic Phantoms and MOSFET Dosimeters [J].
Miksys, Nelson ;
Gordon, Christopher L. ;
Thomas, Karen ;
Connolly, Bairbre L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) :1315-1322
[39]   Determination of the effective dose for CT examinations and influence of the setup parameters [J].
Koller, F. ;
Roth, J. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (01) :36-43
[40]   Can Contrast Media Increase Organ Doses in CT Examinations? A Clinical Study [J].
Amato, Ernesto ;
Salamone, Ignazio ;
Naso, Serena ;
Bottari, Antonio ;
Gaeta, Michele ;
Blandino, Alfredo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) :1288-1293