Predictive Value of Intraoperative Neuromonitoring in Brainstem Cavernous Malformation Surgery

被引:6
|
作者
Rauschenbach, Laurel [1 ]
Santos, Alejandro N. [1 ]
Dinger, Thiemo F.
Herten, Annika [1 ]
Oppong, Marvi Darkwah [1 ]
Schmidt, Borge [2 ]
Chihi, Mehdi [1 ]
Haubold, Johannes [3 ]
Jabbarli, Ramazan [1 ]
Wrede, Karsten H. [1 ]
Sure, Ulrich [1 ]
Dammann, Philipp [1 ]
机构
[1] Univ Hosp Essen, Dept Neurosurg & Spine Surg, Essen, Germany
[2] Univ Hosp Essen, Inst Med Informat Biometry & Epidemiol, Essen, Germany
[3] Univ Hosp Essen, Inst Diagnost & Intervent Radiol, Essen, Germany
关键词
Brainstem; Cerebral cavernous malformation; Electrophysiological monitoring; Evoked potentials; Intraoperative neuromonitoring; Surgery; NATURAL-HISTORY; SPINAL-CORD; INFRATENTORIAL LESIONS; CEREBRAL-CORTEX; MOTOR PATHWAYS; RESECTION; HEMORRHAGE; METAANALYSIS;
D O I
10.1016/j.wneu.2021.09.064
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the predictive value of intraoperative neuromonitoring (IONM) in brainstem cavernous malformation (BSCM) surgery. METHODS: Surgically treated patients with BSCM were included. All patients received IONM consisting of motor evoked potentials (MEPs) and somatosensory-evoked potentials (SSEPs). Neurologic examination was conducted preoperatively and at discharge and follow-up >3 months after BSCM removal. Demographic, radiographic, and clinical features were assessed. Study end points were new motor or somatosensory deficits and functional disability. RESULTS: A total of 62 patients were included. MEP decrease was associated with new motor deficits at discharge (P = 0.022), and SSEP decrease was associated with new somatosensory deficits at discharge (P < 0.001) and follow-up (P < 0.001). Sensitivity and specificity values for MEPs (discharge: 31% and 93%; follow-up: 33% and 91%) and SSEPs (discharge: 82% and 80%; follow-up: 85% and 79%) were calculated, respectively. Receiver operating characteristic analyses with area under the curve (AUC) metrics revealed acceptable performance of MEPs (AUC, 0.75; P = 0.022) and SSEPs (AUC, 0.72; P = 0.004) in predicting early deficits. Intraoperative decrease of MEPs (P = 0.047) and SSEPs (P = 0.017) was associated with early functional disability. Surgery-related subdural air accumulation impaired IONM reliability in predicting early (P = 0.048) and long-term (P = 0.013) deficits. CONCLUSIONS: Established IONM warning criteria may be valid for BSCM removal. However, surgical approaches in the sitting position significantly limit the predictive value of IONM, to some extent because of intraoperative pneumocephalus.
引用
收藏
页码:E359 / E373
页数:15
相关论文
共 50 条
  • [41] Intraoperative Neuromonitoring for Tethered Cord Surgery in Infants: Challenges and Outcome
    Udayakumaran, Suhas
    Nair, Niveditha S.
    George, Mathew
    PEDIATRIC NEUROSURGERY, 2021, : 501 - 510
  • [42] Intraoperative Neuromonitoring for Anterior Cervical Spine Surgery What Is the Evidence?
    Ajiboye, Remi M.
    Zoller, Stephen D.
    Sharma, Akshay
    Mosich, Gina M.
    Drysch, Austin
    Li, Jesse
    Reza, Tara
    Pourtaheri, Sina
    SPINE, 2017, 42 (06) : 385 - 393
  • [43] A Bibliometric Analysis of Intraoperative Neuromonitoring in Spine Surgery
    Fonseca, Pedro
    Goethel, Marcio
    Vilas-Boas, Joao Paulo
    Gutierres, Manuel
    Correia, Miguel Velhote
    WORLD NEUROSURGERY, 2021, 154 : 3 - 12
  • [44] Paradigms of intraoperative neuromonitoring in paediatric thyroid surgery
    Li, Yuchuan
    Zhang, Chunhai
    Zhang, Yi
    Dionigi, Gianlorenzo
    Zhao, Yishen
    Sun, Hui
    Wang, Yingying
    FRONTIERS IN ENDOCRINOLOGY, 2025, 15
  • [45] Functional neurological outcome of spinal cavernous malformation surgery
    Laurèl Rauschenbach
    Alejandro N. Santos
    Adrian Engel
    Angelina Olbrich
    Arnau Benet
    Yen Li
    Börge Schmidt
    Oliver Gembruch
    Neriman Özkan
    Ramazan Jabbarli
    Karsten H. Wrede
    Adrian Siegel
    Michael T. Lawton
    Ulrich Sure
    Philipp Dammann
    European Spine Journal, 2023, 32 : 1714 - 1720
  • [46] Intraoperative Neuromonitoring in Tethered Cord Surgery in Children
    Abu-Ata, Mahmoud M.
    Pasquali, Claudia
    Sala, Francesco
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2024, 41 (02) : 123 - 133
  • [47] Stereotactically guided cavernous malformation surgery
    BoecherSchwarz, HG
    Grunert, P
    Guenthner, M
    Kessel, G
    MuellerForell, W
    MINIMALLY INVASIVE NEUROSURGERY, 1996, 39 (02) : 50 - 55
  • [48] Outcomes of basal ganglia and thalamic cavernous malformation surgery: A meta-analysis
    Kearns, Kathryn N.
    Chen, Ching-Jen
    Tvrdik, Petr
    Park, Min S.
    Kalani, M. Yashar S.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 73 : 209 - 214
  • [49] Recovery of consciousness after a brainstem cavernous malformation hemorrhage: A descriptive study of preserved reticular activating system with tractography
    Ordonez-Rubiano, Edgar G.
    Johnson, Jason M.
    Younus, Iyan
    Avila, Mauricio J.
    Fonseca-Mazeau, Pierre Y.
    Marin-Munoz, Jorge H.
    Cortes-Lozano, William
    Enciso-Olivera, Cesar O.
    Ordonez-Mora, Edgar G.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 59 : 372 - 377
  • [50] Use of Intraoperative Neuromonitoring in Surgical Treatment of Acute Presentation of Chiari I Malformation: A Case Report
    Ng, Christina
    Vazquez, Sima
    Auerbach-Tash, Rose
    Naftchi, Alexandria F. F.
    Dominguez, Jose F. F.
    Singh, Aalok R. R.
    Overby, Philip
    Muh, Carrie R. R.
    JOURNAL OF NEUROLOGICAL SURGERY REPORTS, 2023, 84 (01) : E26 - E30