Signal -Amplified Near -Infrared Ratiometric Electrochemiluminescence Aptasensor Based on Multiple Quenching and Enhancement Effect of Graphene/Gold Nanorods/G-Quadruplex

被引:64
作者
Shao, Kang [1 ]
Wang, Biru [1 ]
Ye, Shiyi [1 ]
Zuo, Yunpeng [1 ]
Wu, Long [1 ]
Li, Qin [1 ]
Lu, Zhicheng [1 ]
Tan, XueCai [2 ]
Han, Heyou [1 ]
机构
[1] Huazhong Agr Univ, Coll Sci, Coll Food Sci & Technol, State Key Lab Agr Microbiol, Wuhan 430070, Peoples R China
[2] Guangxi Univ Nationalities, Sch Chem & Chem Engn, Nanning 530008, Peoples R China
基金
中国国家自然科学基金;
关键词
RESONANCE ENERGY-TRANSFER; GOLD NANORODS; QUANTUM DOTS; ELECTROGENERATED CHEMILUMINESCENCE; ULTRASENSITIVE DETECTION; MICRORNA DETECTION; AMPLIFICATION; NANOPARTICLES; LUMINOL; IMMUNOSENSOR;
D O I
10.1021/acs.analchem.6b01935
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual-signaling ratiometric electrochemiluminescence technology has attracted particular attention in analytical science due to its precise measurement to normalize variation in environmental changes. Creating new mated ECL report units with two emitting states and improving the detection sensitivity are major challenges for ratiometric ECL measurement. Here, we. fabricate an ultrasensitive near-infrared ratiometric ECL aptasensor based on a dual-potential signal amplification strategy "triggered by the quencher/enhancer [graphene/hemin/gold nanorods/Gquadruplex hemin (rGO-H-AuNRs-G(4)H) composite]. The composite was initially prepared through three consecutive steps: the pi-pi stacking interaction between heroin and graphene, in-site growth of AuNRs, and Surface ligand exchange. Dual ECL quenching of quantum dots (QDs) and multiple signal enhancement of luminol can be achieved simultaneOusly by the fabrication of the sandwich "thrombin aptamer I (TBA(1))-TB-TBA(2) (rGO-H-AuNRs-G(4)H)" mode: (i) the formation Of three-dimensional G-quadruplex between aptather and thrombin not only shortens the distance between the donor (QDs) and receptor (rGO-H and AuNRs) to trigger electrochemiluminescence energy: transfer but also provides :the place for intercalating hemin;.(ii) the hemin intercalated into G(4) structure and heroin Connected onto rGO together with AuNRs/rGO nanomaterials can achieve the multiple peroxidase-like catalysis of H(2)0(2) to greatly enhance the ECL of luminol. The ratiometric ECL aptasensor self-calibrated by the internal reference (luminol or QDs) exhibits ultrasensitive and accurate analytical performance toward thrombin (TB) with a linear detection range from 100 ng/mL to 0.5 pg/mL and a detection limit of 4.2 fg/mL [defined as signal-to-noise ratio (S/N) = 3].
引用
收藏
页码:8179 / 8187
页数:9
相关论文
共 9 条
  • [1] Target-triggered signal-on ratiometric electrochemiluminescence sensing of PSA based on MOF/Au/G-quadruplex
    Shao, Kang
    Wang, Biru
    Nie, Axiu
    Ye, Shiyi
    Ma, Jing
    Li, Zhonghua
    Lv, Zhicheng
    Han, Heyou
    BIOSENSORS & BIOELECTRONICS, 2018, 118 : 160 - 166
  • [2] A novel "dual-potential" ratiometric electrochemiluminescence DNA sensor based on enhancing and quenching effect by G-quadruplex/hemin and Au-Luminol bifunctional nanoparticles
    Wang, Yanfeng
    Shan, Duoliang
    Wu, Guofan
    Ru, Fan
    Zhang, Xiaohui
    Li, Linfang
    Qian, Yaxuan
    Lu, Xiaoquan
    Hung, Wang
    BIOSENSORS & BIOELECTRONICS, 2018, 106 : 64 - 70
  • [3] A pseudo triple-enzyme cascade amplified aptasensor for thrombin detection based on hemin/G-quadruplex as signal label
    Yi, Huayu
    Xu, Wenju
    Yuan, Yali
    Bai, Lijuan
    Wu, Yongmei
    Chai, Yaqin
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 415 - 420
  • [4] An ultra-high-sensitivity electrochemiluminescence aptasensor for Pb2+ detection based on the synergistic signal-amplification strategy of quencher abscission and G-quadruplex generation
    Liu, Xiaohong
    Li, Libo
    Li, Fang
    Zhao, Wanlin
    Luo, Lijun
    Bi, Xiaoya
    Li, Xia
    You, Tianyan
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 424
  • [5] A chemiluminescence aptasensor for thrombin detection based on aptamer-conjugated and hemin/G-quadruplex DNAzyme signal-amplified carbon fiber composite
    Sun, Yuanling
    Wang, Xueying
    Xu, Han
    Ding, Chaofan
    Lin, Yanna
    Luo, Chuannan
    Wei, Qin
    ANALYTICA CHIMICA ACTA, 2018, 1043 : 132 - 141
  • [6] An amplified electrochemical aptasensor for thrombin detection based on pseudobienzymic Fe3O4-Au nanocomposites and electroactive hemin/G-quadruplex as signal enhancers
    Jing, Pei
    Xu, Wenju
    Yi, Huayu
    Wu, Yongmei
    Bai, Lijuan
    Yuan, Ruo
    ANALYST, 2014, 139 (07) : 1756 - 1761
  • [7] Highly sensitive electrochemiluminescence "turn-on" aptamer sensor for lead(II) ion based on the formation of a G-quadruplex on a graphene and gold nanoparticles modified electrode
    Hai, Hong
    Yang, Feng
    Li, Jianping
    MICROCHIMICA ACTA, 2014, 181 (9-10) : 893 - 901
  • [8] Graphene oxide@gold nanorods-based multiple-assisted electrochemiluminescence signal amplification strategy for sensitive detection of prostate specific antigen
    Cao, Jun-Tao
    Yang, Jiu-Jun
    Zhao, Li-Then
    Wang, Yu-Ling
    Wang, Hui
    Liu, Yan-Ming
    Ma, Shu-Hui
    BIOSENSORS & BIOELECTRONICS, 2018, 99 : 92 - 98
  • [9] A highly sensitive electrochemiluminescence assay for protein kinase based on double-quenching of graphene quantum dots by G-quadruplex-hemin and gold nanoparticles
    Liu, Jinquan
    He, Xiaoxiao
    Wang, Kemin
    He, Dinggeng
    Wang, Yonghong
    Mao, Yinfei
    Shi, Hui
    Wen, Li
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 54 - 60