Inerter-added transmissibility to control base displacement in isolated structures

被引:10
作者
Morales, Cesar A. [1 ]
机构
[1] Univ Peruana Ciencias Aplicadas, Fac Ingn, Lima, Peru
关键词
Base isolation; Passive control; Base displacement; Inerter; Isolator displacement; TUNED MASS DAMPER; ISOLATED BUILDINGS; SEISMIC RESPONSE; PERFORMANCE; DESIGN; SYSTEM; MOTION;
D O I
10.1016/j.engstruct.2021.113564
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A solution to the large base displacement problem in isolated structures under seismic loads is proposed; it is based on a displacement transmissibility formulation that includes the inerter device. The solution is also based on a novel spectral characterization of ground displacement; it should be clear that if the problem is displacement, the focus must be on displacements, both, as the excitation: ground displacement (rather than acceleration which is the norm) and as isolator displacement, through a transmissibility that relates both input and output displacements, all of which is a new approach. The proposal can serve as a passive-control design procedure, either under near-field or far-field conditions, when an inerter at the base level is chosen to solve the large isolator displacement problem. An isolated structural model commonly used in the subject literature is employed to show that the base displacement level can be reduced to under the ground displacement level, which implies a positive comparison with previous passive and active control solutions, including inerter solutions; in fact, the design aim is a competitive 0.95 ratio for both displacements.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Wind-induced vibration control of base-isolated high-rise buildings by using tuned mass damper inerter [J].
Huergo, Ivan F. ;
Hernandez-Barrios, Hugo ;
Morales-Napoles, Oswaldo .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2025,
[42]   Tuned mass-damper-inerter control of wind-induced vibration of flexible structures based on inerter location [J].
Dai, Jun ;
Xu, Zhao-Dong ;
Gai, Pan-Pan .
ENGINEERING STRUCTURES, 2019, 199
[43]   An innovative negative stiffness-inerter hybrid control device toward seismic-resilient structures [J].
Kiran, K. K. ;
Farsangi, Ehsan Noroozinejad ;
Gharehbaghi, Vahidreza .
INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2022, 7 (05)
[44]   Dynamic analysis and vulnerability reduction of asymmetric structures: Fixed base vs base isolated system [J].
De Angelis, Fabio ;
Cancellara, Donato .
COMPOSITE STRUCTURES, 2019, 219 :203-220
[45]   Adaptive backstepping control of hysteretic base-isolated structures [J].
Pozo, F ;
Ikhouane, F ;
Pujol, G ;
Rodellar, J .
JOURNAL OF VIBRATION AND CONTROL, 2006, 12 (04) :373-394
[46]   Hysteresis based vibration control of base-isolated structures [J].
Rodellar, Jose ;
Garcia, Guillem ;
Vidal, Yolanda ;
Acho, Leonardo ;
Pozo, Francesc .
X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 :1798-1803
[47]   Active control schemes for aseismic base-isolated structures [J].
Soldatos, AG ;
Arvanitis, KG ;
Zacharenakis, EC .
ARCHIVE OF APPLIED MECHANICS, 2002, 72 (2-3) :147-159
[48]   Output feedback sliding mode control of base isolated structures [J].
Luo, N ;
Rodellar, J ;
De la Sen, M ;
Vehi, J .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2000, 337 (05) :555-577
[49]   Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings [J].
De Domenico, Dario ;
Deastra, Predaricka ;
Ricciardi, Giuseppe ;
Sims, Neil D. ;
Wagg, David J. .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (14) :7626-7649
[50]   Adaptive control of base-isolated structures against near-field earthquakes using variable friction dampers [J].
Ozbulut, Osman E. ;
Bitaraf, Maryam ;
Hurlebaus, Stefan .
ENGINEERING STRUCTURES, 2011, 33 (12) :3143-3154