Reconstruction of the Subaxial Cervical Spine Using Pedicle Screw Instrumentation

被引:98
作者
Abumi, Kuniyoshi [1 ]
Ito, Manabu [2 ]
Sudo, Hideki [2 ]
机构
[1] Hokkaido Univ, Dept Spinal Reconstruct, Grad Sch Med, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Dept Adv Med Spine & Spinal Cord Disorders, Grad Sch Med, Sapporo, Hokkaido 0608638, Japan
关键词
cervical spine; cervical deformity; pedicle screw; reconstructive surgery; CLINICAL ACCURACY; FIXATION; COMPLICATIONS; INSERTION; PLACEMENT; LESIONS;
D O I
10.1097/BRS.0b013e318239cf1f
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Review article. Objective. To review the indications, detailed techniques, and complications of cervical pedicle screw fixation procedure. Summary of Background Data. Although screw insertion into the cervical pedicles has been considered too risky for the neurovascular structures except C2 and C7, biomechanical studies revealed a superior stabilizing effect of pedicle screw fixation in the cervical spine to other fixation procedures including lateral mass screw fixation. In addition, several investigators reported superior reconstructive results of unstable cervical spine. Methods. A literature review and review of the authors' experience in the treatment of the patients with unstable cervical spine and/or cervical spinal deformities using cervical pedicle screw fixation procedure. Results. Pedicle screw fixation is biomechanically most reliable for reconstruction of the cervical spine in various kinds of disorders. Previously reported articles revealed that pedicle screw fixation is useful for reconstruction of unstable cervical spine and correction of cervical deformities. Neurovascular complication by this procedure cannot be completely eliminated; however, it can be minimized by sufficient preoperative imaging studies and strict control of screw placement during surgery. Modern technology of computer navigation system and newly developing aiming devices can be expected to increase the accuracy of screw placement. Conclusion. Pedicle screw provides excellent 3-dimensional fixations and is a useful procedure for reconstruction of the cervical spine in various kinds of disorders. Possible neurovascular complication can be minimized by sufficient preoperative imaging studies and strict control of screw placement during surgery.
引用
收藏
页码:E349 / E356
页数:8
相关论文
共 24 条
  • [1] Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    Abumi, K
    Takada, T
    Shono, Y
    Kaneda, K
    Fujiya, M
    [J]. SPINE, 1999, 24 (14) : 1425 - 1434
  • [2] Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
    Abumi, K
    Shono, Y
    Ito, M
    Taneichi, H
    Kotani, Y
    Kaneda, K
    [J]. SPINE, 2000, 25 (08) : 962 - 969
  • [3] One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    Abumi, K
    Kaneda, K
    Shono, Y
    Fujiya, M
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 19 - 26
  • [4] TRANSPEDICULAR SCREW FIXATION FOR TRAUMATIC LESIONS OF THE MIDDLE AND LOWER CERVICAL-SPINE - DESCRIPTION OF THE TECHNIQUES AND PRELIMINARY-REPORT
    ABUMI, K
    ITOH, H
    TANEICHI, H
    KANEDA, K
    [J]. JOURNAL OF SPINAL DISORDERS, 1994, 7 (01): : 19 - 28
  • [5] Pedicle screw fixation for nontraumatic lesions of the cervical spine
    Abumi, K
    Kaneda, K
    [J]. SPINE, 1997, 22 (16) : 1853 - 1863
  • [6] Correction of cervical kyphosis using pedicle screw fixation systems
    Abumi, K
    Shono, Y
    Taneichi, H
    Ito, M
    Kaneda, K
    [J]. SPINE, 1999, 24 (22) : 2389 - 2396
  • [7] Abumi K, 2000, SPINE, V25, P2906
  • [8] COMPLICATIONS OF POSTERIOR CERVICAL PLATING
    HELLER, JG
    SILCOX, DH
    SUTTERLIN, CE
    [J]. SPINE, 1995, 20 (22) : 2442 - 2448
  • [9] A late neurological complication following posterior correction surgery of severe cervical kyphosis
    Hojo, Yoshihiro
    Ito, Manabu
    Abumi, Kuniyoshi
    Kotani, Yoshihisa
    Sudo, Hideki
    Takahata, Masahiko
    Minami, Akio
    [J]. EUROPEAN SPINE JOURNAL, 2011, 20 (06) : 890 - 898
  • [10] Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement
    Ishikawa, Yoshimoto
    Kanemura, Tokumi
    Yoshida, Go
    Ito, Zenya
    Muramoto, Akio
    Ohno, Shuichiro
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (05) : 606 - 611