Segmentation of the Common Carotid Intima-Media Complex in Ultrasound Images Using Active Contours

被引:49
|
作者
Petroudi, Styliani [1 ]
Loizou, Christos [2 ]
Pantziaris, Marios [3 ]
Pattichis, Constantinos [1 ]
机构
[1] Univ Cyprus, Dept Comp Sci, CY-1678 Nicosia, Cyprus
[2] Intercoll, Dept Comp Sci, CY-51604 Limassol, Cyprus
[3] Cyprus Inst Neurol & Genet, CY-23462 Nicosia, Cyprus
关键词
Active contours; carotid artery; intima-media thickness; level sets; segmentation; ultrasound imaging; OF-THE-ART; AUTOMATED-METHOD; HOUGH TRANSFORM; THICKNESS; RISK; VARIABILITY; ALGORITHM; DISEASE; SNAKES; SYSTEM;
D O I
10.1109/TBME.2012.2214387
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The segmentation of the intima-media complex (IMC) of the common carotid artery (CCA) wall is important for the evaluation of the intima media thickness (IMT) on B-mode ultrasound (US) images. The IMT is considered an important marker in the evaluation of the risk for the development of atherosclerosis. The fully automated segmentation algorithm presented in this article is based on active contours and active contours without edges and incorporates anatomical information to achieve accurate segmentation. The level set formulation by Chan and Vese using random initialization provides a segmentation of the CCA US images into different distinct regions, one of which corresponds to the carotid wall region below the lumen and includes the far wall IMC. The segmented regions are used to automatically achieve image normalization, which is followed by speckle removal. The resulting smoothed lumen-intima boundary combined with anatomical information provide an excellent initialization for parametric active contours that provide the final IMC segmentation. The algorithm is extensively evaluated on 100 different cases with ground truth (GT) segmentation available from two expert clinicians. The GT mean IMT value is 0.6679 mm +/- 0.1350 mm and the corresponding automatically segmented (AS) mean IMT value is 0.6054 mm +/- 0.1464 mm. The mean absolute difference between the GT IMT and the IMT evaluated from from the AS region is 0.095 mm +/- 0.0615 mm. The polyline distance is 0.096 mm +/- 0.034 mm while the Hausdorff distance is 0.176 mm +/- 0.047 mm. The algorithm compares favorably to both automatic and semiautomatic methods presented in the literature.
引用
收藏
页码:3060 / 3069
页数:10
相关论文
共 50 条
  • [31] Ultrasound Evaluation of Carotid Intima-Media Thickness in Children
    Epifanio, Matias
    Baldisserotto, Matteo
    Sarria, Edgar E.
    Lazaretti, Arthur
    Mattiello, Rita
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2015, 22 (11) : 1141 - 1147
  • [32] Detection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique
    Santhiyakumari, N.
    Rajendran, P.
    Madheswaran, M.
    Suresh, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (11) : 1299 - 1310
  • [33] Detection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique
    N. Santhiyakumari
    P. Rajendran
    M. Madheswaran
    S. Suresh
    Medical & Biological Engineering & Computing, 2011, 49 : 1299 - 1310
  • [34] A Comparison of Ultrasound Intima-Media Thickness Measurements of the Left and Right Common Carotid Artery
    Loizou, Christos P.
    Nicolaides, Andrew
    Kyriacou, Efthyvoulos
    Georghiou, Niki
    Griffin, Maura
    Pattichis, Constantinos S.
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2015, 3
  • [35] Computerized analysing system using the active contour in ultrasound measurement of carotid artery intima-media thickness
    Schmidt-Trucksäss, A
    Cheng, DC
    Sandrock, M
    Schulte-Mönting, J
    Rauramaa, R
    Huonker, M
    Burkhardt, H
    CLINICAL PHYSIOLOGY, 2001, 21 (05): : 561 - 569
  • [36] P2.17: Echogenicity of the Common Carotid Artery Intima-Media Complex in Stroke
    K. Aizawa
    S. Elyas
    D. D. Adingupu
    A. C. Shore
    W. D. Strain
    P. E. Gates
    Artery Research, 2013, 7 (3-4) : 123 - 123
  • [37] The echogenecity of the intima-media complex in the common carotid artery is closely related to the echogenecity in plaques
    Lind, Lars
    Andersson, Jessika
    Roenn, Monika
    Gustavsson, Tomas
    ATHEROSCLEROSIS, 2007, 195 (02) : 411 - 414
  • [38] Effects of Smoking on Intima-Media Thickness of the Common Carotid Artery Using Ultrasonography
    Alsiddig, Asmaa Mustafa
    Ali, Ibrahim Abdelrhim
    ARTERY RESEARCH, 2024, 30 (01)
  • [39] Ultrasound intima-media segmentation using Hough transform and dual snake model
    Xu, Xiangyang
    Zhou, Yuan
    Cheng, Xinyao
    Song, Enmin
    Li, Guokuan
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (03) : 248 - 258
  • [40] An update on carotid ultrasound measurement of intima-media thickness - Discussion
    Guerci, A
    Nissen, SE
    Crouse, JR
    Ballantyne, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A): : 38B - 39B