Soft x-ray measurements in the FN-II dense plasma focus device for different anode configurations

被引:0
作者
Rojo-Blanco, C. [1 ]
Castillo-Mejia, F. [2 ]
Rangel-Gutierrez, J. [2 ]
Herrera-Velazquez, J. J. E. [2 ]
机构
[1] Univ Nacl Autonoma Mexico, Fac Ciencias, Circuito Exterior S-N,Ciudad Univ, Mexico City 04510, DF, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Ciencias Nucl, Mexico City 04511, DF, Mexico
来源
14TH LATIN AMERICAN WORKSHOP ON PLASMA PHYSICS (LAWPP 2011) | 2012年 / 370卷
关键词
EMISSION;
D O I
10.1088/1742-6596/370/1/012057
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A study of the soft x-ray emission is presented, for a low energy (4.8 kJ) dense plasma focus device. Three Quantrad Si PIN-diodes with differential filter combinations of Be, Al, Ti, Ni, and Mo are employed as time-resolved x-ray detectors. The x-ray flux in different energy windows is measured as function of the deuterium filling pressure. A comparison is made for three anode configurations: (a) hollow, (b) flat, and (c) 2mm diameter W needle.
引用
收藏
页数:8
相关论文
共 7 条
[1]  
Castillo F, 2002, BRAZ J PHYS, V32, P3, DOI 10.1590/S0103-97332002000100002
[2]   Small plasma focus studied as a source of hard X-ray [J].
Castillo-Mejía, F ;
Milanese, MM ;
Moroso, RL ;
Pouzo, JO ;
Santiago, MA .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2001, 29 (06) :921-926
[3]   PRODUCTION OF HIGHLY CHARGED METAL-IONS AND SOFT-X-RAY EMISSION IN A PLASMA-FOCUS [J].
HIRANO, K ;
YAMAMOTO, T ;
TAKADA, S ;
SONE, H ;
SHIMODA, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1988, 27 (01) :89-94
[4]   Plasma focus as a possible x-ray source for radiography [J].
Hussain, S ;
Shafiq, M ;
Ahmad, R ;
Waheed, A ;
Zakaullah, M .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (01) :61-69
[5]   FORMATION OF A HIGH-DENSITY DEUTERIUM PLASMA FOCUS [J].
MATHER, JW .
PHYSICS OF FLUIDS, 1965, 8 (02) :366-&
[6]   FILAMENTARY STRUCTURE OF THE PINCH COLUMN IN PLASMA-FOCUS DISCHARGES [J].
SADOWSKI, M ;
HEROLD, H ;
SCHMIDT, H ;
SHAKHATRE, M .
PHYSICS LETTERS A, 1984, 105 (03) :117-123
[7]   Efficiency of plasma focus for argon K-series line radiaton emission [J].
Zakaullah, M ;
Alamgir, K ;
Murtaza, G ;
Waheed, A .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2000, 9 (04) :592-596