Drug-Eluting Stents in Preclinical Studies Updated Consensus Recommendations for Preclinical Evaluation

被引:169
作者
Schwartz, Robert S. [1 ]
Edelman, Elazer [2 ]
Virmani, Renu [3 ]
Carter, Andrew [4 ]
Granada, Juan F. [5 ]
Kaluza, Greg L. [5 ]
Chronos, Nicolas A. F. [6 ]
Robinson, Keith A. [6 ]
Waksman, Ron [7 ]
Weinberger, Judah [8 ]
Wilson, Gregory J. [9 ]
Wilensky, Robert L. [10 ]
机构
[1] Minneapolis Heart Inst Fdn, Minneapolis, MN 55407 USA
[2] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[3] CV Path Int Registry Pathol, Gaithersburg, MD USA
[4] D3 Consultants, Las Vegas, NV USA
[5] Cardiovasc Res Fdn, New York, NY USA
[6] St Josephs Translat Res Inst, Atlanta, GA USA
[7] Washington Hosp Ctr, Washington, DC 20010 USA
[8] Columbia Univ, New York, NY USA
[9] Univ Toronto, Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[10] Univ Penn Hlth Syst, Philadelphia, PA USA
关键词
drugs; restenosis; stents;
D O I
10.1161/CIRCINTERVENTIONS.108.789974
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary drug-eluting stents are commonplace in clinical practice with acceptable safety and efficacy. Preclinical evaluation of novel drug-eluting stent technologies has great importance for understanding safety and possibly efficacy of these technologies, and well-defined preclinical testing methods clearly benefit multiple communities within the developmental, testing, and clinical evaluation chain. An earlier consensus publication enjoyed widespread adoption but is in need of updating. This publication is an update, presenting an integrated view for testing drug-eluting technologies in preclinical models, including novel devices such as bioabsorbable coatings, totally bioabsorbable stents, bifurcation stents, and stent-free balloon-based drug delivery. This consensus document was produced by preclinical and translational scientists and investigators engaged in interventional technology community. The United States Food and Drug Administration (USFDA) recently issued a Draft Guidance for Industry Document for Drug-Eluting Stents. This expert consensus document is consistent with the Food and Drug Administration guidance. The dynamic nature of this field mandates future modifications and additions that will be added over time. (Circ Cardiovasc Intervent. 2008;1:143-153.)
引用
收藏
页码:143 / 153
页数:11
相关论文
共 26 条
[11]  
Nakazawa G, 2007, HERZ, V32, P274, DOI 10.1007/s00059-007-2997-9
[12]   Short- and long-term effects of a novel paclitaxel coated stent in the porcine coronary model [J].
Scheller, Bruno ;
Kuehler, Michael ;
Cremers, Bodo ;
Mahnkopf, Dirk ;
Boehm, Michael ;
Boxberger, Michael .
CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (02) :118-123
[13]   Preclinical restenosis models and drug-eluting stents - Still important, still much to learn [J].
Schwartz, RS ;
Chronos, NA ;
Virmani, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (07) :1373-1385
[14]   Drug-eluting Stents in preclinical studies - Recommended evaluation from a consensus group [J].
Schwartz, RS ;
Edelman, ER .
CIRCULATION, 2002, 106 (14) :1867-1873
[15]   RESTENOSIS AND THE PROPORTIONAL NEOINTIMAL RESPONSE TO CORONARY-ARTERY INJURY - RESULTS IN A PORCINE MODEL [J].
SCHWARTZ, RS ;
HUBER, KC ;
MURPHY, JG ;
EDWARDS, WD ;
CAMRUD, AR ;
VLIETSTRA, RE ;
HOLMES, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :267-274
[16]   Serial imaging and histology illustrating the degradation of a bioabsorbable magnesium stent in a porcine coronary artery [J].
Slottow, Tina L. Pinto ;
Pakala, Rajbabu ;
Waksman, Ron .
EUROPEAN HEART JOURNAL, 2008, 29 (03) :314-314
[17]   Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model [J].
Suzuki, T ;
Kopia, G ;
Hayashi, S ;
Bailey, LR ;
Llanos, G ;
Wilensky, R ;
Klugherz, BD ;
Papandreou, G ;
Narayan, P ;
Leon, MB ;
Yeung, AC ;
Tio, F ;
Tsao, PS ;
Falotico, R ;
Carter, AJ .
CIRCULATION, 2001, 104 (10) :1188-1193
[18]   Preclinical restenosis models: Challenges and successes [J].
Touchard, AG ;
Schwartz, RS .
TOXICOLOGIC PATHOLOGY, 2006, 34 (01) :11-18
[19]  
*US GOV, GUID IND CO IN PRESS
[20]  
van der Giessen W J, 1998, Semin Interv Cardiol, V3, P125