A Micro-computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars

被引:20
|
作者
Piasecki, Lucila [1 ]
dos Reis, Paulo Jose [2 ]
Jussiani, Eduardo Inocente [3 ]
Andrello, Avacir Casanova [3 ]
机构
[1] SUNY Buffalo, Dept Periodont & Endodont, 240 Squire Hall, Buffalo, NY 14214 USA
[2] State Univ Cent West, Dept Phys, Guarapuava, Parana, Brazil
[3] Univ Estadual Londrina, Phys Dept, Appl Nucl Phys Lab, Londrina, Parana, Brazil
关键词
Apex ID; CanalPro; electronic apex locator; micro-computed tomography; Root ZX; working length; WORKING LENGTH DETERMINATION; IN-VIVO; ROOT CANALS; MESIAL ROOT; FORAMEN; TEETH;
D O I
10.1016/j.joen.2018.09.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study evaluated the accuracy of 3 electronic apex locators (EALs) (CanalPro [ColteneEndo, Cuyahoga Falls, OH], Apex ID [SybronEndo, Glendora, CA], and Root ZX Mini [J Morita, Tokyo, Japan]) in curved mesial canals of extracted mandibular molars using micro-computed tomographic (micro-CT) scanning. Methods: The root canal length and the actual working length of 58 canals were measured using the visual method and 3-dimensional micro-CT reconstructions. The measurements of the EALs at marks "APEX/0.0" and "0.5 mark" were recorded as the electronic root canal length and the electronic working length, respectively. The absolute mean values and the percentages of distribution of the electronic measurements were compared with the actual lengths of the canals. The presence of isthmuses, accessory canals, foramen position, and the distance between the apical constriction and the apical foramen were recorded from the microCT scans, and their correlation to the accuracy of the EALs was determined. Results: All electronic measurements showed high agreement with their respective gold standard, except the electronic root canal length of the Apex ID (P < .05). No difference in the percentage of precise measurements (within the +/- 0.5 mm) was found among the devices (chi(2) and z tests, P > .05). Of the anatomic parameters evaluated, the presence of a lateral foramen negatively affected the 0.0 mark of the Apex ID (Wilcoxon test, P < .05). Conclusions: The Root ZX Mini and CanalPro were precise for both root canal length and working length determination in mesial curved canals of mandibular molars, whereas the Apex ID was accurate for the working length when using the 0.5 mark.
引用
收藏
页码:1872 / 1877
页数:6
相关论文
共 50 条
  • [1] Clinical Accuracy and Precision of 3 Multifrequency Electronic Apex Locators Assessed through Micro-Computed Tomographic Imaging
    De-Deus, Gustavo
    Cozer, Viviany
    Souza, Erick Miranda
    Silva, Emmanuel Joao Nogueira Leal
    Belladonna, Felipe Goncalves
    Simoes-Carvalho, Marco
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2023, 49 (05) : 487 - 495
  • [2] The Use of Micro-Computed Tomography to Determine the Accuracy of 2 Electronic Apex Locators and Anatomic Variations Affecting Their Precision
    Piasecki, Lucila
    Carneiro, Everdan
    da Silva Neto, Ulisses Xavier
    Ditzel Westphalen, Vania Portela
    Brandao, Christian Giampietro
    Gambarini, Gianluca
    Azim, Adham A.
    JOURNAL OF ENDODONTICS, 2016, 42 (08) : 1263 - 1267
  • [3] Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed Tomography Study
    Cinar, Firdevs
    Ustun, Yakup
    EUROPEAN ENDODONTIC JOURNAL, 2020, 5 (03): : 226 - 230
  • [4] Micro-computed tomographic analysis of the mesial root of mandibular first molars with bifid apex
    Keles, Ali
    Keskin, Cangul
    Alqawasmi, Rawan
    Versiani, Marco Aurelio
    ARCHIVES OF ORAL BIOLOGY, 2020, 117
  • [5] The use of micro-computed tomography to determine the accuracy of electronic working length with two apex locators
    Suguro, Hisashi
    Nishihara, Anna
    Tamura, Takahito
    Nakamura, Takeshi
    Toyama, Yurika
    Takeichi, Osamu
    JOURNAL OF ORAL SCIENCE, 2021, 63 (02) : 167 - 169
  • [6] Effects of different irrigation solutions on the accuracy of electronic apex locators in curved and straight root canals
    Tekinarslan, Dide
    Erkal, Damla
    Pehlivan, Burcu
    Unal, Elif
    Kayar, Goknur
    Koc, Simay
    Er, Kursat
    GIORNALE ITALIANO DI ENDODONZIA, 2023, 37 (01): : 54 - 61
  • [7] Micro-Computed Tomography Study of the Internal Anatomy of Mesial Root Canals of Mandibular Molars
    Villas-Boas, Marcelo Haas
    Bernardineli, Norberti
    Cavenago, Bruno Cavalini
    Marciano, Marina
    del Carpio-Perochena, Aldo
    de Moraes, Ivaldo Gomes
    Duarte, Marco H.
    Bramante, Clovis M.
    Ordinola-Zapata, Ronald
    JOURNAL OF ENDODONTICS, 2011, 37 (12) : 1682 - 1686
  • [8] Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation
    Barakat, Reem M.
    Almohareb, Rahaf A.
    Alharbi, Arwa O.
    Alhazmi, Asma
    Alomar, Reem
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [9] The isthmuses of the mesial root of mandibular molars: a micro-computed tomographic study
    Mannocci, F
    Peru, M
    Sherriff, M
    Cook, R
    Ford, TRP
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (08) : 558 - 563
  • [10] Micro-Computed Tomography Analysis of Resin and Calcium Silicate Based Sealers Removal in Mandibular Molars Curved Canals
    Buyuksungur, Arda
    Oncu, Aysenur
    Koohnavard, Mehrdad
    Celikten, Berkan
    Tezer, Emine Odabasi
    Huang, Yan
    Orhan, Kaan
    ACTA STOMATOLOGICA CROATICA, 2024, 58 (02) : 136 - 144