A noninvasive method for extracting bivalve DNA from the water-filled mantle cavity

被引:6
|
作者
Kurita, Yoshihisa [1 ]
Kijima, Akihiro [2 ]
机构
[1] Kyushu Univ, Grad Sch Agr Sci, 4-46-24 Tsuyazaki, Fukutsu, Fukuoka 8113304, Japan
[2] Tohoku Univ, Grad Sch Agr Sci, 3-1 Mukai, Onagawa, Miyagi 9862242, Japan
关键词
Mollusk; Genetics; Environmental water; GENETIC DIVERSITY; POPULATIONS; BROUGHTONII; EVOLUTION; SEQUENCE;
D O I
10.1007/s10750-018-3835-1
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
Genetic studies play a great role for determining the biology of bivalves, particularly those covering population genetics, phylogeny, breeding, stock management, and conservation. However, DNA sampling methods that require removal of bivalves from the water and/or opening of their shells often cause stress and damage to bivalves, which can be lethal. The invasiveness of DNA sampling has made it difficult to conduct genetic studies in threatened species, rare species, and/or breeding lineages. In the present study, we developed a non-invasive method for bivalve DNA sampling using the water-filled mantle cavity (WMC). Our method can extract DNA from a small WMC sample (about 100 mu l), collected using a fine needle and syringe without opening the shell. We demonstrated that the WMC sample contains intact mitochondrial and nuclear DNA. DNA contamination from other organisms, such as adjacent bivalve individuals, did not affect the resulting PCR and DNA sequencing analyses. Finally, the individuals from whom WMC was collected remained alive for more than 2months after the experiments. This non-invasive method will be of great assistance in investigating the genetics of bivalves.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [1] A noninvasive method for extracting bivalve DNA from the water-filled mantle cavity
    Yoshihisa Kurita
    Akihiro Kijima
    Hydrobiologia, 2019, 829 : 237 - 243
  • [2] A simple and reliable method for DNA extraction from bivalve mantle
    Futoshi Aranishi
    Takane Okimoto
    Journal of Applied Genetics, 2006, 47 : 251 - 254
  • [3] A simple and reliable method for DNA extraction from bivalve mantle
    Aranishi, Futoshi
    Okimoto, Takane
    JOURNAL OF APPLIED GENETICS, 2006, 47 (03) : 251 - 254
  • [4] Validation of a medium-frequency computational method for the coupling between a plate and a water-filled cavity
    David, JM
    Menelle, M
    JOURNAL OF SOUND AND VIBRATION, 2003, 265 (04) : 841 - 861
  • [5] Validation of a modal method by use of an appropriate static potential for a plate coupled to a water-filled cavity
    David, J. -M.
    Menelle, M.
    JOURNAL OF SOUND AND VIBRATION, 2007, 301 (3-5) : 739 - 759
  • [6] TRANSITION TO UNSTEADY NATURAL-CONVECTION IN A TALL WATER-FILLED CAVITY
    LEQUERE, P
    PHYSICS OF FLUIDS A-FLUID DYNAMICS, 1990, 2 (04): : 503 - 515
  • [7] Comments on "Validation of a medium-frequency computational method for the coupling between a plate and a water-filled cavity"
    Laura, PAA
    Vera, SA
    JOURNAL OF SOUND AND VIBRATION, 2004, 276 (3-5) : 1115 - 1116
  • [8] Application of the SWT method to scattering from water-filled elastic spherical shells
    School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
    Chuan Bo Li Xue, 1600, 6 (705-715):
  • [9] Shallow Reflection Method for Water-Filled Void Detection and Characterization
    Zahari, M. N. H.
    Madun, A.
    Dahlan, S. H.
    Joret, A.
    Hazreek, Z. A. M.
    Mohammad, A. H.
    Izzaty, R. A.
    INTERNATIONAL SEMINAR ON MATHEMATICS AND PHYSICS IN SCIENCES AND TECHNOLOGY 2017 (ISMAP 2017), 2018, 995
  • [10] NONINVASIVE TEMPERATURE PROFILING USING MULTIFREQUENCY MICROWAVE RADIOMETRY IN THE PRESENCE OF WATER-FILLED BOLUS
    MIZUSHINA, S
    MATSUDA, M
    MATSUI, K
    HAMAMURA, Y
    SUGIURA, T
    IEICE TRANSACTIONS ON COMMUNICATIONS ELECTRONICS INFORMATION AND SYSTEMS, 1991, 74 (05): : 1293 - 1302