Performance of solar air heater ducts with different types of ribs on the absorber plate

被引:98
作者
Tanda, Giovanni [1 ]
机构
[1] Univ Genoa, DIMSET, I-16145 Genoa, Italy
关键词
Roughened channel; Solar air heater; Effective efficiency; Entropy generation; FRICTION FACTOR CORRELATIONS; TRANSFER COEFFICIENT; THERMOHYDRAULIC PERFORMANCE; ARTIFICIAL ROUGHNESS; TRANSVERSE; COLLECTOR; FLOW; EFFICIENCY; SURFACES; ENERGY;
D O I
10.1016/j.energy.2011.08.043
中图分类号
O414.1 [热力学];
学科分类号
摘要
Repeated ribs are considered an effective technique to enhance forced convection heat transfer in channels. In order to establish the performance of rib-roughened channels, both heat transfer and friction characteristics have to be accounted for. In the present paper, heat transfer coefficients and friction factors have been experimentally investigated for a rectangular channel having one wall roughened by repeated ribs and heated at uniform flux, while the remaining three walls were smooth and insulated. Angled continuous ribs, transverse continuous and broken ribs, and discrete V-shaped ribs were considered as rib configurations. Different performance evaluation criteria, based on energy balance or entropy generation analysis, were proposed to assess the relative merit of each rib configuration. All the rib-roughened channels performed better than the reference smooth channel in the medium-low range of the investigated Reynolds number values, which is that typically encountered in solar air heater applications. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6651 / 6660
页数:10
相关论文
共 37 条
[1]   Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate [J].
Aharwal, K. R. ;
Gandhi, Bhupendra K. ;
Saini, J. S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (25-26) :5970-5977
[3]  
Bejan A., 1993, HEAT TRANSFER
[4]  
Bejan A., 1982, Entropy Generation through heat and fluid flow
[5]  
Bergles A. E., 1974, Letters in Heat and Mass Transfer, V1, P113, DOI 10.1016/0094-4548(74)90147-7
[6]  
BERGLES AE, 1974, 5 INT HEAT TRANSF C, P239
[7]   Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate [J].
Bhagoria, JL ;
Saini, JS ;
Solanki, SC .
RENEWABLE ENERGY, 2002, 25 (03) :341-369
[8]   A review on methodology of artificial roughness used in duct of solar air heaters [J].
Bhushan, Brij ;
Singh, Ranjit .
ENERGY, 2010, 35 (01) :202-212
[9]   IMPROVEMENT OF THE EFFICIENCY OF A BARE SOLAR COLLECTOR BY MEANS OF TURBULENCE PROMOTERS [J].
CORTES, A ;
PIACENTINI, R .
APPLIED ENERGY, 1990, 36 (04) :253-261
[10]   Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates [J].
Esen, Hikmet .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1046-1054