Buffering zone of implantable Collamer lens sizing in V4c

被引:34
作者
Nam, Seung Wan [1 ]
Lim, Dong Hui [1 ,2 ]
Hyun, Joo [1 ,3 ]
Chung, Eui-Sang [1 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, 81 Irwon Ro, Seoul 06351, South Korea
[2] Catholic Univ Korea, Grad Sch, Dept Prevent Med, Seoul, South Korea
[3] Saevit Eye Hosp, Goyang, South Korea
来源
BMC OPHTHALMOLOGY | 2017年 / 17卷
关键词
Implantable collamer lens; Postoperative vault; Sulcus-to-sulcus diameter; PHAKIC INTRAOCULAR-LENS; WHITE-TO-WHITE; ULTRASOUND BIOMICROSCOPY; CONTACT-LENS; CENTRAL HOLE; HIGH MYOPIA; VAULT; OPACITIES; CATARACTS; DIAMETER;
D O I
10.1186/s12886-017-0663-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. Methods: V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), and the V4 ICL sizes were then converted to V4c ICL sizes with a size-converting table. We defined the "normalsizing group" as having a pre-converted ICL size larger than the STS, and the "under-sizing group" as having a preconverted ICL size smaller than the STS. Refractive outcomes, safety and parameters related to postoperative vault were compared between the two groups. Results: The value of "actual ICL size-STS" differed significantly between the normal-sizing and under-sizing groups (p< 0.001), but postoperative vault did not differ significantly (p = 0.442). The demographics, implanted ICL characteristics, effectiveness indexes, safety indexes, and parameters related to postoperative vault did not differ significantly between the two groups (p > 0.05). Two patients in the normal-sizing group exhibited over-vaulting; these patients had shallow anterior chambers and were implanted with high-dioptric-power ICLs. Conclusions: The achievement of acceptable vault in both normal-sizing and under-sizing groups indicates the existence of a buffering zone in V4c ICL sizing. The smaller size of V4c ICLs should be considered in patients susceptible to overvaulting, such as those with shallow anterior chambers and high-dioptric-power ICLs.
引用
收藏
页数:6
相关论文
共 25 条
  • [1] Long-term evaluation of the central vault after phakic CollamerA® lens (ICL) implantation using OCT
    Alfonso, Jose F.
    Fernandez-Vega, L.
    Lisa, C.
    Fernandes, P.
    Gonzalez-Meijome, J.
    Montes-Mico, R.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1807 - 1812
  • [2] Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
    Alfonso, Jose F.
    Lisa, Carlos
    Palacios, Ana
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) : 978 - 983
  • [3] Imaging of posterior chamber phakic intraocular lens by optical coherence tomography
    Bechmann, M
    Ullrich, S
    Thiel, MJ
    Kenyon, KR
    Ludwig, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 360 - 363
  • [4] Cao Xin-fang, 2013, Zhonghua Yan Ke Za Zhi, V49, P235
  • [5] Comparison Over Time of Vault in Chinese Eyes Receiving Implantable Contact Lenses With or Without a Central Hole
    Cao, Xinfang
    Wu, Weiliang
    Wang, Yang
    Xie, Chen
    Shen, Ye
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 172 : 111 - 117
  • [6] Choi KH, 2007, J REFRACT SURG, V23, P362
  • [7] Changes in Iridocorneal Angle Structure and Trabecular Pigmentation With STAAR Implantable Collamer Lens During 2 Years
    Chung, Tae-Young
    Park, Sung Chul
    Lee, Myoung Ok
    Ahn, Kyeon
    Chung, Eui-Sang
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) : 251 - 258
  • [8] Phakic intraocular lenses
    Espandar, Ladan
    Meyer, Jay J.
    Moshirfar, Majid
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) : 349 - 356
  • [9] Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation
    Jiménez-Alfaro, I
    del Castillo, JMB
    García-Feijoó, J
    de Bernabé, JGG
    de la Iglesia, JMS
    [J]. OPHTHALMOLOGY, 2001, 108 (01) : 90 - 99
  • [10] Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Ando, Wakako
    Igarashi, Akihito
    Iijima, Kei
    Koh, Ayaka
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) : 67 - 72