An integrated dual-functional electrodialytic membrane suppressor (D-EMS) is proposed that can simultaneously conduct suppression of acid and base eluent. It consists of four chambers, equivalent to half an anion electrolytic membrane suppressor (EMS) plus half a cation EMS with typical sandwiched configuration via a bipolar membrane (BPM). Anion exchange membrane, BPM and cation exchange membrane are respectively used to isolate two central eluent channels from two outer regenerant chambers. A constant current source is used to power D-EMS. The device shows similar performance to a separate EMS in terms of suppression capacity (>= 80 mu eq/min, corresponding to 80 mM eluent at the flow rate of 1 mL/min) and the resultant suppressed background (similar to 0.75 mu S/cm and similar to 0.17 mu S/cm for anion and cation section of D-EMS, respectively). (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:4
相关论文
共 13 条
[1]   Ion exchange membranes in ion chromatography and related applications [J].
Dasgupta, Purnendu K. ;
Maleki, Fereshteh .
TALANTA, 2019, 204 :89-137
[2]   Developments in suppressor technology for inorganic ion analysis by ion chromatography using conductivity detection [J].
Haddad, PR ;
Jackson, PE ;
Shaw, MJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :725-742
[3]   Electrochemically generated multifunctional suppressor for ion chromatography [J].
Hu, RZ ;
Weng, YH ;
Lai, LM ;
Chen, JC ;
Lin, Q .
CHROMATOGRAPHIA, 2003, 57 (7-8) :471-474
[4]   Recent developments in electrolytic devices for ion chromatography [J].
Liu, Y ;
Srinivasan, K ;
Pohl, C ;
Avdalovic, N .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 60 (03) :205-232
[5]   Fabrication of a two-membrane configured electrodialytic methanesulfonic acid generator for ion chromatography [J].
Lu, Yifei ;
Zhao, Lili ;
Lin, Shiyuan ;
Zhang, Feifang ;
Yang, Bingcheng .
ANALYST, 2019, 144 (07) :2411-2415
[6]   Online Gas-Free Electrodialytic KOH Eluent Generator for Ion Chromatography [J].
Lu, Yifei ;
Zhou, Liting ;
Yang, Bingcheng ;
Huang, Shujun ;
Zhang, Feifang .
ANALYTICAL CHEMISTRY, 2018, 90 (21) :12840-12845
[7]   NEW MEMBRANE-BASED ELECTROLYTIC SUPPRESSOR DEVICE FOR SUPPRESSED CONDUCTIVITY DETECTION IN ION CHROMATOGRAPHY [J].
RABIN, S ;
STILLIAN, J ;
BARRETO, V ;
FRIEDMAN, K ;
TOOFAN, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :97-109
[8]   QA/QC activities and ecological monitoring in the Acid Deposition Monitoring Network in East Asia (EANET) [J].
Sase, H. ;
Nakayama, S. ;
Leong, C. P. ;
Kamisako, M. ;
Luangjame, J. ;
Garivait, H. ;
Visaratana, T. ;
Kietvuttinon, B. ;
Ueda, H. .
IFOREST-BIOGEOSCIENCES AND FORESTRY, 2009, 2 :26-29
[9]   A new suppressor design for low noise performance with carbonate eluents for Ion Chromatography [J].
Srinivasan, Kannan ;
Omphroy, Brittany K. ;
Lin, Rong ;
Pohl, Christopher A. .
TALANTA, 2018, 188 :152-160
[10]   ELECTRODIALYTIC MEMBRANE SUPPRESSOR FOR ION CHROMATOGRAPHY [J].
STRONG, DL ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1989, 61 (09) :939-945