Mapping initial and general recombination in scanning proton pencil beams

被引:13
作者
Christensen, J. B. [1 ]
Almhagen, E. [2 ,3 ]
Stolarczyk, L. [2 ,4 ]
Liszka, M. [4 ]
Hernandez, G. G. [5 ]
Bassler, N. [6 ,7 ,8 ]
Norrevang, O. [9 ]
Vestergaard, A. [9 ]
机构
[1] Tech Univ Denmark, Ctr Nucl Technol, Roskilde, Denmark
[2] Skandionkliniken, Uppsala, Sweden
[3] Uppsala Univ, Dept Immunol Med Radiat Sci Genet & Pathol, Uppsala, Sweden
[4] Polish Acad Sci Krakow, Bronowice Cyclotron Ctr, Inst Nucl Phys, Krakow, Poland
[5] Aarhus Univ, Dept Phys & Astron, Aarhus, Denmark
[6] Stockholm Univ, Dept Phys, Med Radiat Phys, Stockholm, Sweden
[7] Karolinska Inst, Dept Oncol & Pathol, Med Radiat Phys, Stockholm, Sweden
[8] Aarhus Univ Hosp, Dept Expt Clin Oncol, Aarhus, Denmark
[9] Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
关键词
ion recombination; initial recombination; general recombination; particle therapy; particle dosimetry; PLATE IONIZATION-CHAMBER; ION RECOMBINATION; COLLECTION; DOSIMETRY; PHOTON; AIR;
D O I
10.1088/1361-6560/ab8579
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k(s) is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min(-1) in air. The Boutillon formalism is used to separate the initial and general recombination. The general recombination is compared to predictions from the numerical recombination code IonTracks and the initial recombination to the Jaffe theory. k(s) is furthermore calculated with the two-voltage method (TVM) and extrapolation approaches, in particular the recently proposed three-voltage (3VL) method. The TVM is in agreement with the Boutillon method and IonTracks for dose rates above 100 Gy min(-1). However, the TVM calculated k(s) is closer related to the Jaffe theory for initial recombination for lower dose rate, indicating a limited application in scanning light ion beams. The 3VL is in turn found to generally be in agreement with Boutillon's method. The recombination is mapped as a function of the dose rate and proton energy at the two centres using the Boutillon formalism: the initial recombination parameter was found to be A = (0.10 +/- 0.01) V at DCPT and A = (0.22 +/- 0.13) V at Skandion, which is in better agreement with the Jaffe theory for initial recombination than previously reported values. The general recombination parameter was estimated to m2=(4.7 +/- 0.1).103V2nA-1cm-1m2=(7.2 +/- 0.1).103V2nA-1cm-1<i. Furthermore, the numerical algorithm IonTracks is demonstrated to correctly predict the initial recombination at low dose rates and the general recombination at high dose rates.
引用
收藏
页数:12
相关论文
共 28 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   A beam model for focused proton pencil beams [J].
Almhagen, E. ;
Boersma, D. J. ;
Nystrom, H. ;
Ahnesjo, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 :27-32
[3]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[4]  
Andreo P., 2000, Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water TRS 398 IAEA,
[5]   Recombination factors for the cylindrical FC65-G ionization chamber in pulsed photon beams and the plane-parallel Roos ionization chamber in pulsed electron beams [J].
Berg, M ;
Noerrevang, O .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23) :5309-5318
[7]   The effect of free-electron collection on the recombination correction to ionization measurements of pulsed radiation [J].
Boag, JW ;
Hochhauser, E ;
Balk, OA .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05) :885-897
[8]   CURRENT COLLECTION AND IONIC RECOMBINATION IN SMALL CYLINDRICAL IONIZATION CHAMBERS EXPOSED TO PULSED RADIATION [J].
BOAG, JW ;
CURRANT, J .
BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (629) :471-478
[9]   Volume recombination parameter in ionization chambers [J].
Boutillon, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2061-2072
[10]   A general algorithm for calculation of recombination losses in ionization chambers exposed to ion beams [J].
Christensen, Jeppe Brage ;
Tolli, Heikki ;
Bassler, Niels .
MEDICAL PHYSICS, 2016, 43 (10) :5484-5492