Maximum likelihood estimation of the distribution of target registration error

被引:2
作者
Moghari, Mehdi Hediazi [1 ]
Abolmaesumi, Purang [1 ]
机构
[1] Queens Univ, Elect & Computer Eng Dept, Kingston, ON K7L 3N6, Canada
来源
MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2 | 2008年 / 6918卷
关键词
target registration error; fiducial localization error; error distribution; inhomogeneous noise; anisotropic noise; isotropic noise;
D O I
10.1117/12.768868
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Estimating the alignment accuracy is an important issue in rigid-body point-based registration algorithms. The registration accuracy depends on the level of the noise perturbing the registering data sets. The noise in the data sets arises from the fiducial (point) localization error (FLE) that may have an identical or inhomogeneous, isotropic or anisotropic distribution at each point in each data set. Target registration error (TRE) has been defined in the literature, as an error measure in terms of FLE, to compute the registration accuracy at a point (target) which is not used in the registration process. In this paper, we mathematically derive a general solution to approximate the distribution of TRE after registration of two data sets in the presence of FLE having any type of distribution. The Maximum Likelihood (ML) algorithm is proposed to estimate the registration parameters and their variances between two data sets. The variances are then used in a closed-form solution, previously presented by these authors, to derive the distribution of TRE at a target location. Based on numerical simulations, it is demonstrated that the derived distribution of TRE, in contrast to the existing methods in the literature, accurately follows the distribution generated by Monte Carlo simulation even when FLE has an inhomogeneous isotropic or anisotropic distribution.
引用
收藏
页数:12
相关论文
共 21 条
  • [1] LEAST-SQUARES FITTING OF 2 3-D POINT SETS
    ARUN, KS
    HUANG, TS
    BLOSTEIN, SD
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) : 699 - 700
  • [2] BALACHANDRAN R, 2005, P SPIE MED IMAGING V
  • [3] Darabi K, 1997, INT CONGR SER, V1134, P920
  • [4] EVANS AC, 1993, INTERACTIVE IMAGE GU, V1898, P63
  • [5] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [6] Derivation of expected registration error for point-based rigid-body registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 16 - 27
  • [7] The distribution of target registration error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 917 - 927
  • [8] POSE ESTIMATION FROM CORRESPONDING POINT DATA
    HARALICK, RM
    JOO, H
    LEE, CN
    ZHUANG, XH
    VAIDYA, VG
    KIM, MB
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1989, 19 (06): : 1426 - 1446
  • [9] ACCURATE FRAMELESS REGISTRATION OF MR AND CT IMAGES OF THE HEAD - APPLICATIONS IN PLANNING SURGERY AND RADIATION-THERAPY
    HILL, DLG
    HAWKES, DJ
    GLEESON, MJ
    COX, TCS
    STRONG, AJ
    WONG, WL
    RUFF, CF
    KITCHEN, ND
    THOMAS, DGT
    SOFAT, A
    CROSSMAN, JE
    STUDHOLME, C
    GANDHE, AJ
    GREEN, SEM
    ROBINSON, GP
    [J]. RADIOLOGY, 1994, 191 (02) : 447 - 454
  • [10] CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING ORTHONORMAL MATRICES
    HORN, BKP
    HILDEN, HM
    NEGAHDARIPOUR, S