Deterioration and recovery effects in energy responses of semiconductor X-ray detectors due to nuclear-fusion produced neutron irradiation

被引:6
作者
Kohagura, J [1 ]
Cho, T
Hirata, M
Numakura, T
Minami, R
Yoshida, M
Watanabe, H
Ito, H
Yokoyama, N
Yatsu, K
Miyoshi, S
Hirano, K
Maezawa, H
Kondoh, T
Hori, J
Nishitani, T
机构
[1] Univ Tsukuba, Plasma Res Ctr, Tsukuba, Ibaraki 3058577, Japan
[2] High Energy Res Org, Ibaraki 3050801, Japan
[3] Japan Atom Energy Res Inst, Ibaraki 3191195, Japan
关键词
semiconductor detector; neutron damage; X-ray energy response;
D O I
10.1016/j.nima.2003.08.151
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effects of neutron irradiation on X-ray energy responses of silicon semiconductor detectors have been investigated. Neutron irradiation experiments were carried out for n-type photodiode arrays utilized in the Joint European Torus (JET) using deuterium (D) beam-injection into a tritium (T) target for a well-calibrated deuterium-tritium (D-T) fusion neutron production at the Fusion Neutronics Source (FNS) facility of Japan Atomic Energy Research Institute. X-ray energy responses of these detectors are characterized before and after irradiation by the use of synchrotron radiation from a 2.5 GeV positron storage ring at the Photon Factory of High Energy Accelerator Research Organization (KEK). A recovery of the degraded X-ray energy response after the neutron irradiation has been found at fluences beyond around 10(13) neutrons/cm(2). A further novel finding is followed as a "re-degradation" by a neutron irradiation level over about 10(14) neutrons/cm(2). This "non-linear response" may be physically interpreted in terms of a type inversion from n- to p-type silicon in the detectors. Long-term observations of X-ray energy responses of the detectors after neutron irradiation have also been made in order to clarify the "annealing effect". (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:300 / 303
页数:4
相关论文
共 19 条
  • [1] JET soft x-ray diagnostic systems
    Alper, B
    Dillon, S
    Edwards, AW
    Gill, RD
    Robins, R
    Wilson, DJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) : 778 - 781
  • [2] Effects of neutrons on semiconductor x-ray detectors including n-type Joint European Torus and p-type GAMMA 10 tomography detectors
    Cho, T
    Kohagura, J
    Hirata, M
    Sakamoto, Y
    Numakura, T
    Minami, R
    Sasuga, T
    Nishizawa, Y
    Okamura, T
    Tamano, T
    Yatsu, K
    Miyoshi, S
    Hirano, K
    Maezawa, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) : 577 - 580
  • [3] EVIDENCE AGAINST EXISTING X-RAY-ENERGY RESPONSE THEORIES FOR SILICON-SURFACE-BARRIER SEMICONDUCTOR-DETECTORS
    CHO, T
    TAKAHASHI, E
    HIRATA, M
    YAMAGUCHI, N
    TERAJI, T
    MATSUDA, K
    TAKEUCHI, A
    KOHAGURA, J
    YATSU, K
    TAMANO, T
    KONDOH, T
    AOKI, S
    ZHANG, XW
    MAEZAWA, H
    MIYOSHI, S
    [J]. PHYSICAL REVIEW A, 1992, 46 (06): : R3024 - R3027
  • [4] NEW FINDINGS OF X-RAY-ENERGY RESPONSES OF SILICON SURFACE-BARRIER DETECTORS AND THEIR GENERALIZED THEORETICAL EXTENSION TO X-RAY RESPONSES OF POSITION-SENSITIVE DETECTORS
    CHO, T
    HIRATA, M
    OHAGURA, J
    YATSU, K
    TAMANO, T
    MIYOSHI, S
    KONDOH, T
    TANABE, Y
    SAITOH, Y
    AKAMINE, T
    MIYAHARA, S
    TANAKA, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) : 475 - 478
  • [5] X-RAY STUDIES OF VARIOUS SHAPES OF ELECTRON-VELOCITY DISTRIBUTION-FUNCTIONS AND OF ELECTRON CONFINEMENT AFFECTED BY KILOVOLT-RANGE ELECTROSTATIC POTENTIALS
    CHO, T
    HIRATA, M
    TAKAHASHI, E
    OGURA, K
    MASAI, K
    YAMAGUCHI, N
    KONDOH, T
    MATSUDA, K
    HOJO, H
    INUTAKE, M
    ISHII, K
    KIWAMOTO, Y
    MASE, A
    SAITO, T
    YATSU, K
    MIYOSHI, S
    [J]. PHYSICAL REVIEW A, 1992, 45 (04): : 2532 - 2545
  • [6] SNAKE-LIKE DENSITY PERTURBATIONS IN JET
    GILL, RD
    EDWARDS, AW
    PASINI, D
    WELLER, A
    [J]. NUCLEAR FUSION, 1992, 32 (05) : 723 - 735
  • [7] ANALYSIS OF NUCLEAR-RADIATION-INDUCED NOISE IN SPECTROSCOPIC AND X-RAY-DIAGNOSTICS DURING HIGH-POWER DEUTERIUM-TRITIUM EXPERIMENTS ON THE TOKAMAK FUSION TEST REACTOR
    HILL, KW
    ADLER, H
    BITTER, M
    FREDRICKSON, E
    VONGOELER, S
    HSUAN, H
    JANOS, A
    JOHNSON, D
    RAMSEY, AT
    RENDA, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01) : 913 - 915
  • [8] Holmes-Siedle A., 2002, Handbook of Radiation Effects
  • [9] Effects of nuclear fusion produced neutrons on silicon semiconductor plasma X-ray detectors
    Kohagura, J
    Cho, T
    Hirata, M
    Numakura, T
    Minami, R
    Watanabe, H
    Sasuga, T
    Nishizawa, Y
    Yoshida, A
    Nagashima, S
    Tamano, T
    Yatsu, K
    Miyoshi, S
    Hirano, K
    Maezawa, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) : 215 - 219
  • [10] Investigation of x-ray-energy responses of semiconductor detectors under deuterium-tritium fusion-produced neutron irradiation
    Kohagura, J
    Cho, T
    Hirata, M
    Numakura, T
    Minami, R
    Yoshida, M
    Nagashima, S
    Watanabe, H
    Yatsu, K
    Miyoshi, S
    Kondoh, T
    Nishitani, T
    Takeuchi, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01) : 805 - 808