Background: Modular dual taper femoral neck designs have been associated with taper corrosion requiring revision surgery. However, outcomes after revision dual taper total hip arthroplasty in patients with symptomatic adverse local tissue reaction due to taper corrosion remain largely unknown. Methods: A total of 198 revision surgeries in 187 patients with dual taper femoral stem total hip arthroplasty with minimum 12-month follow-up were evaluated. Results: At mean follow-up of 18 months, at least 1 complication had occurred in 39 patients (20%) of 198 revisions. Single episode of dislocation, treated with close reduction, occurred in 16, whereas 2 patients required rerevision due to multiple dislocations. Infection requiring rerevision occurred in 3 patients. Adverse local tissue reaction recurrence requiring reoperation occurred in 6 patients. Implant survivorship for revision for any cause was 86% at 30 months. The reoperation rate of revised dual taper was 8% (16 out of 198 hips). The median serum levels of cobalt, chromium, and cobalt/chromium ratio decreased (P < .01) from 5.3 mu g/L (range: 2.3-48.5 mu g/L), 2.6 mu g/L (range: 0.2-64 mu g/L), and 4.7 (range: 2.1-35) prerevision to 1.4 mu g/L (range: 0.2-8.8 mu g/L), 0.7 mu g/L (range: 0.1-3.9 mu g/L), and 2.2 (range: 0.4-8.8) postrevision, respectively. Conclusion: This pilot study demonstrates that intraoperative tissue necrosis was associated with a high rate of early complications (20%) and revisions (8%), suggesting the importance of a systematic evaluation of these patients including metal ion levels and metal artifact reduction sequence magnetic resonance imaging in optimizing revision outcome, as early diagnosis will facilitate the initiation of appropriate treatment before significant adverse tissue necrosis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1549 / 1554
页数:6
相关论文
共 50 条
  • [41] Total Elbow Arthroplasty: Clinical Outcomes, Complications, and Revision Surgery
    Kwak, Jae-Man
    Koh, Kyoung-Hwan
    Jeon, In-Ho
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (04) : 369 - 379
  • [42] Early death following revision total hip arthroplasty
    Jones, Mark D.
    Parry, Michael
    Whitehouse, Michael R.
    Blom, Ashley W.
    HIP INTERNATIONAL, 2018, 28 (04) : 400 - 406
  • [43] Influence of FeCl3 and H2O2 in corrosion testing of modular taper connections in total hip arthroplasty: An in vitro study
    Bormann, Therese
    Nebel, Laura
    Mueller, Ulrike
    Mai, Phuong Thao
    Gibmeier, Jens
    Renkawitz, Tobias
    Kretzer, J. Philippe
    ACTA BIOMATERIALIA, 2022, 145 : 427 - 435
  • [44] Early Discharge for Revision Total Knee and Hip Arthroplasty: Predictors of Success
    Albana, Mohamed F.
    Yayac, Michael F.
    Sun, Kelly
    Post, Zachary D.
    Ponzio, Danielle Y.
    Ong, Alvin C.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (05) : 1298 - 1303
  • [45] Early outcomes of using custom-made augments in revision total hip arthroplasty
    R. M. Tikhilov
    A. A. Dzhavadov
    A. S. Demin
    S. S. Bilyk
    A. O. Denisov
    I. I. Shubnyakov
    International Orthopaedics, 2022, 46 : 2229 - 2235
  • [46] Intraarticular Hip Injection and Early Revision Surgery Following Total Hip Arthroplasty A Retrospective Cohort Study
    Ravi, Bheeshma
    Escott, Benjamin G.
    Wasserstein, David
    Croxford, Ruth
    Hollands, Simon
    Paterson, J. Michael
    Kreder, Hans J.
    Hawker, Gillian A.
    ARTHRITIS & RHEUMATOLOGY, 2015, 67 (01) : 162 - 168
  • [47] Technical Note: Is Corrosion a Threat to the Strength of the Taper Connection in Femoral Components of Total Hip Replacements?
    Higgs, Genymphas B.
    MacDonald, Daniel W.
    Lowell, Julie
    Padayatil, Alexander
    Mihalko, William M.
    Siskey, Ryan L.
    Gilbert, Jeremy L.
    Rimnac, Clare M.
    Kurtz, Steven M.
    CORROSION, 2017, 73 (12) : 1538 - 1543
  • [48] Compliant interfaces and fretting corrosion of modular taper junctions in total hip implants: The micromechanics of contact
    Smith, Stephanie M.
    Gilbert, Jeremy L.
    TRIBOLOGY INTERNATIONAL, 2020, 151
  • [49] Short-Term Outcomes and Complications After Rejuvenate Modular Total Hip Arthroplasty Revision
    Barlow, Brian T.
    Boles, John W.
    Lee, Yuo-yu
    Ortiz, Philippe A.
    Westrich, Geoffrey H.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04) : 857 - 862
  • [50] Mid-Term Outcomes of Dual Mobility Acetabular Cups for Revision Total Hip Arthroplasty
    Harwin, Steven F.
    Sultan, Assem A.
    Khlopas, Anton
    Chughtai, Morad
    Sodhi, Nipun
    Piuzzi, Nicolas S.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05) : 1494 - 1500