Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients

被引:32
作者
Dimitriou, Dimitris [1 ]
Liow, Ming Han Lincoln [1 ]
Tsai, Tsung-Yuan [1 ]
Leone, William A. [2 ]
Li, Guoan [1 ]
Kwon, Young-Min [1 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Orthopaed Surg, 55 Fruit St, Boston, MA 02114 USA
[2] Holy Cross Hosp, Orthoped Ctr, Dept Orthopaed Surg, Ft Lauderdale, FL USA
关键词
revision total hip arthroplasty; taper corrosion; clinical outcomes; modular femoral neck stem; dual taper; systematic evaluation; LOCAL TISSUE REACTION; MODULAR-NECK; FEMORAL IMPLANTS; FOLLOW-UP; METAL; PSEUDOTUMOR; RESURFACINGS; REPLACEMENT; STEMS;
D O I
10.1016/j.arth.2016.01.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Modular dual taper femoral neck designs have been associated with taper corrosion requiring revision surgery. However, outcomes after revision dual taper total hip arthroplasty in patients with symptomatic adverse local tissue reaction due to taper corrosion remain largely unknown. Methods: A total of 198 revision surgeries in 187 patients with dual taper femoral stem total hip arthroplasty with minimum 12-month follow-up were evaluated. Results: At mean follow-up of 18 months, at least 1 complication had occurred in 39 patients (20%) of 198 revisions. Single episode of dislocation, treated with close reduction, occurred in 16, whereas 2 patients required rerevision due to multiple dislocations. Infection requiring rerevision occurred in 3 patients. Adverse local tissue reaction recurrence requiring reoperation occurred in 6 patients. Implant survivorship for revision for any cause was 86% at 30 months. The reoperation rate of revised dual taper was 8% (16 out of 198 hips). The median serum levels of cobalt, chromium, and cobalt/chromium ratio decreased (P < .01) from 5.3 mu g/L (range: 2.3-48.5 mu g/L), 2.6 mu g/L (range: 0.2-64 mu g/L), and 4.7 (range: 2.1-35) prerevision to 1.4 mu g/L (range: 0.2-8.8 mu g/L), 0.7 mu g/L (range: 0.1-3.9 mu g/L), and 2.2 (range: 0.4-8.8) postrevision, respectively. Conclusion: This pilot study demonstrates that intraoperative tissue necrosis was associated with a high rate of early complications (20%) and revisions (8%), suggesting the importance of a systematic evaluation of these patients including metal ion levels and metal artifact reduction sequence magnetic resonance imaging in optimizing revision outcome, as early diagnosis will facilitate the initiation of appropriate treatment before significant adverse tissue necrosis. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1549 / 1554
页数:6
相关论文
共 50 条
  • [21] Early outcomes of using custom-made augments in revision total hip arthroplasty
    Tikhilov, R. M.
    Dzhavadov, A. A.
    Demin, A. S.
    Bilyk, S. S.
    Denisov, A. O.
    Shubnyakov, I. I.
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (10) : 2229 - 2235
  • [22] Revision total hip arthroplasty with a Kerboull plate: comparative outcomes using standard versus dual mobility cups
    Assi, Chahine
    Caton, Jacques
    Fawaz, Wissam
    Samaha, Camille
    Yammine, Kaissar
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (10) : 2245 - 2251
  • [23] Validating a Simplified Method for Assessing Total Hip Arthroplasty Taper Corrosion Susceptibility with a 15-Year Retrieval Database
    Aldinger, Patrick
    Cartner, Jacob
    Jones, Bob
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 113 - 131
  • [24] Clinically significant corrosion at the head-neck taper interface in total hip arthroplasty: a systematic review and case series
    Carli, Alberto
    Politis, Angelos
    Zukor, David
    Huk, Olga
    Antoniou, John
    HIP INTERNATIONAL, 2015, 25 (01) : 7 - 14
  • [25] Risk Stratification Algorithm for Management of Patients with Dual Modular Taper Total Hip Arthroplasty: Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society
    Kwon, Young-Min
    Fehring, Thomas K.
    Lombardi, Adolph V.
    Barnes, C. Lowry
    Cabanela, Miguel E.
    Jacobs, Joshua J.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11) : 2060 - 2064
  • [26] Postoperative outcomes and survival rates after aseptic revision total hip arthroplasty What can patients expect from revision surgery?
    Hoffmann, Manuela
    Reichert, Johannes C.
    Rakow, Anastasia
    Schoon, Janosch
    Wassilew, Georgi I.
    ORTHOPADIE, 2023, 52 (01): : 3 - 11
  • [27] Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty
    Sutter, E. Grant
    McClellan, Taylor R.
    Attarian, David E.
    Bolognesi, Michael P.
    Lachiewicz, Paul F.
    Wellman, Samuel S.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09) : S220 - S224
  • [28] Femoral stem taper geometry and porous coating in cementless direct anterior primary total hip arthroplasty
    McCrosson, Matthew
    Broadfoot, Jackson
    Yeager, Matthew
    Marquess, Ben
    Scheinberg, Mila
    Naranje, Sameer
    JOURNAL OF ORTHOPAEDICS, 2023, 46 : 169 - 173
  • [29] The incidence of adverse local tissue reaction due to head taper corrosion after total hip arthroplasty using V40 taper and 36 mm CoCr head
    Grothe, T.
    Guenther, K-P.
    Hartmann, A.
    Blum, S.
    Haselhoff, R.
    Goronzy, J.
    BONE & JOINT JOURNAL, 2022, 104B (07) : 852 - 858
  • [30] Taper Corrosion in Modular Hip Prostheses Analysis of Serum Metal Ions in 19 Patients
    Vundelinckx, Bart J.
    Verhelst, Luk A.
    De Schepper, Jo
    JOURNAL OF ARTHROPLASTY, 2013, 28 (07) : 1218 - 1223