Performance analysis of a heat exchanger having perforated square fins

被引:111
|
作者
Sahin, Bayram [1 ]
Demir, Alparslan [2 ]
机构
[1] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25240 Erzurum, Turkey
[2] Akad Engn Ltd, Erzurum, Turkey
关键词
heat transfer enhancement; Taguchi method; perforated pin fins; performance analysis; forced air cooling;
D O I
10.1016/j.applthermaleng.2007.04.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present paper reports on heat transfer enhancement and the corresponding pressure drop over a flat surface equipped with square cross-sectional perforated pin fins in a rectangular channel. The channel had a cross-sectional area of 100-250 mm(2). The experiments covered the following range: Reynolds number 13,500-42,000, the clearance ratio (C/H) 0, 0.33 and 1, the inter-fin spacing ratio (S-y/D) 1.208, 1.524, 1.944 and 3.417. Correlation equations were developed for the heat transfer, friction factor and enhancement efficiency. The experimental results showed that the use of the square pin fins may lead to heat transfer enhancement. Enhancement efficiencies varied between 1.1 and 1.9 depending on the clearance ratio and inter-fin spacing ratio. Both lower clearance ratio and lower inter-fin spacing ratio and comparatively lower Reynolds numbers are suggested for higher thermal performance. Using the Taguchi experimental design method, optimum design parameters and their levels were investigated. Nusselt number and friction factor were considered as performance parameters. An L-9(3(3)) orthogonal array was selected as an experimental plan. First of all, each goal was optimized, separately. Then, all the goals were optimized together, considering the priority of the goals. Finally, the optimum results were found to be Reynolds number of 42,000, fin height of 50 mm and streamwise distance between fins of 51 mm. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 632
页数:12
相关论文
共 50 条
  • [1] Thermal performance analysis and optimum design parameters of heat exchanger having perforated pin fins
    Sahin, Bayram
    Demir, Alparslan
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1684 - 1695
  • [2] Performance analysis of a heat exchanger having slotted tube fins
    Kaya, Mehmet
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2019, 34 (01): : 421 - 437
  • [3] Numerical Analysis of Tube Heat Exchanger with Perforated Star-Shaped Fins
    Bosnjakovic, Mladen
    Muhic, Simon
    FLUIDS, 2020, 5 (04)
  • [4] NUMERICAL ANALYSIS ON HEAT TRANSFER AND FLOW RESISTANCE PERFORMANCES OF A HEAT EXCHANGER WITH NOVEL PERFORATED WAVY FINS
    Wang, Xuexi
    Lin, Feng
    THERMAL SCIENCE, 2022, 26 (4B): : 3345 - 3357
  • [5] Analysis of double pipe heat exchanger performance by use of porous fins
    Kahalerras, H.
    Filali, E.G.
    Targui, N.
    International Journal of Heat and Technology, 2007, 25 (02) : 35 - 42
  • [6] Optimum design-parameters of a heat exchanger having hexagonal fins
    Yakut, K
    Alemdaroglu, N
    Sahin, B
    Celik, C
    APPLIED ENERGY, 2006, 83 (02) : 82 - 98
  • [7] PERFORMANCE OF PERFORATED HEAT-EXCHANGER SURFACES
    MONDT, JR
    SIEGLA, DC
    JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1974, 96 (02): : 81 - 86
  • [8] PERFORMANCE OF PERFORATED HEAT-EXCHANGER SURFACES
    MONDT, JR
    SIEGLA, DC
    MECHANICAL ENGINEERING, 1973, 95 (06) : 60 - 61
  • [9] Evaluation of fin efficiency and heat transfer coefficient on the heat exchanger having plate fins
    Kang, HC
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 661 - 666
  • [10] Heat-dissipation performance of cylindrical heat sink with perforated fins
    Song, Gihyun
    Kim, Dong-Hwa
    Song, Dong-Hyung
    Sung, Ju-Bin
    Yook, Se-Jin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 170