Experimental validation of the admittance matrix method on a Y-system

被引:11
作者
Capponi, Caterina [1 ]
Ferrante, Marco [1 ]
Zecchin, Aaron C. [2 ]
Gong, Jinzhe [2 ]
机构
[1] Univ Perugia, Dipartimento Ingn Civile & Ambientale, Via G Duranti 93, I-06125 Perugia, Italy
[2] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
关键词
Admittance matrix; branched system; fluid transient; frequency-domain analysis; network; INVERSE TRANSIENT ANALYSIS; LEAK DETECTION; PIPE SYSTEMS; BLOCKAGE DETECTION; WATER-HAMMER; TRANSMISSION; PIPELINES; DIAGNOSIS; NETWORKS; TIME;
D O I
10.1080/00221686.2017.1372818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the first experimental validation of the network admittance matrix method (NAMM) using experimental data collected from a branched pipeline system during hydraulic transient events. The branched pipeline model is formulated for two model scenarios with different nodal boundary control conditions, namely demand-and pressure-controlled boundary nodes, describing different forms of hydraulic transient excitation for the system. The matrix expressions for these two cases are derived and the effects of these different boundary control conditions, in terms of model structure and simulation accuracy, are investigated. The simulated results are compared with the measured experimental data acquired in the Y-system. The small differences indicate that the admittance matrix method is able to reproduce the experimental data with a good agreement in both the time and frequency domains.
引用
收藏
页码:439 / 450
页数:12
相关论文
共 55 条
[1]   Parameters affecting water-hammer wave attenuation, shape and timing -: Part 1:: Mathematical tools [J].
Bergant, Anton ;
Tusseling, Arris S. ;
Vitkovsky, John P. ;
Covas, Didia I. C. ;
Simpson, Angus R. ;
Lambert, Martin F. .
JOURNAL OF HYDRAULIC RESEARCH, 2008, 46 (03) :373-381
[2]   Pressure waves as a tool for leak detection in closed conduits [J].
Brunone, B. ;
Ferrante, M. .
URBAN WATER JOURNAL, 2004, 1 (02) :145-155
[3]   Automatic control valve-induced transients in operative pipe system [J].
Brunone, B ;
Morelli, L .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1999, 125 (05) :534-542
[4]  
Brunone B, 2008, J AM WATER WORKS ASS, V100, P108
[5]   Leak Detection in a Branched System by Inverse Transient Analysis with the Admittance Matrix Method [J].
Capponi, Caterina ;
Ferrante, Marco ;
Zecchin, Aaron C. ;
Gong, Jinzhe .
WATER RESOURCES MANAGEMENT, 2017, 31 (13) :4075-4089
[6]   Numerical study on accuracy of frequency-domain modelling of transients [J].
Capponi, Caterina ;
Zecchin, Aaron C. ;
Ferrante, Marco ;
Gong, Jinzhe .
JOURNAL OF HYDRAULIC RESEARCH, 2017, 55 (06) :813-828
[7]  
Chaudhry M.H., 2014, Applied Hydraulic Transients, V3rd
[8]   Pressure measurements with valve-induced transient flow in water pipelines [J].
Choi, Doo Yong ;
Kim, Juhwan ;
Lee, Doo-Jin ;
Kim, Dohwan .
URBAN WATER JOURNAL, 2015, 12 (03) :200-206
[9]   Standing wave difference method for leak detection in pipeline systems [J].
Covas, D ;
Ramos, H ;
de Almeida, AB .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2005, 131 (12) :1106-1116
[10]   Water hammer in pressurized polyethylene pipes: conceptual model and experimental analysis [J].
Covas, Didia ;
Stoianov, Ivan ;
Ramos, Helena ;
Graham, Nigel ;
Maksimovic, Cedo ;
Butler, David .
URBAN WATER JOURNAL, 2004, 1 (02) :177-197