Exergo-economic Evaluation of a new drying system Boosted by Ranque-Hilsch vortex tube

被引:87
作者
Acar, Merve Senturk [1 ]
Arslan, Oguz [2 ]
机构
[1] Dumlupinar Univ, Tavsanh Vocat Sch, TR-43300 Kutahya, Turkey
[2] Bilecik Seyh Edebali Univ, Engn Fac, Mech Engn Dept, TR-11230 Bilecik, Turkey
关键词
Drying system; Economic analysis; Energy analysis; Exergy analysis; Vortex tube; NOZZLE NUMBER; PERFORMANCE; REFRIGERATOR; PARAMETERS; ENERGY; RATIO;
D O I
10.1016/j.applthermaleng.2017.06.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a new drying system aided by the hot stream of Ranque-Hilsch vortex tube (RHVT) was designed. Then, the designed system was evaluated by means of energy and exergy analysis from the thermodynamics point of view. Finally, this new system was investigated by means of life cycle analysis coupled with the net present value (NPV) from the economic point of view. In this aim, several RHVTs with the different geometrical helical generators, control valve angles, RHVT bodies and inlet stream pressures were performed experimentally. The obtained results were evaluated in the designing of RHVT aided drying system (RHVTAD). The highest value of NPV of RHVTAD was calculated as 23711.88 is an element of for the h/w = 0.44, d/D = 0.51, L/D = 40, control valve angle of 30 degrees, 3rd control valve opening position. At this case, the operating conditions of this system were T-5 of 328.15 K, T-6 of 308.15 K and P-8 of 601.325 kPa. Under the same circumstances, the energy efficiency of the RHVTAD system was calculated as 0.0348 and 0.0338 while exergy efficiency was calculated as 0.0010 and 0.0023 for the summer and winter modes, respectively. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 44 条
[1]  
AHRENDTS J, 1980, ENERGY, V5, P667, DOI 10.1016/0360-5442(80)90087-0
[2]   Parametric and internal study of the vortex tube using a CFD model [J].
Aljuwayhel, NF ;
Nellis, GF ;
Klein, SA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (03) :442-450
[3]  
Andalibi M., 2012, Int. J. Sci. Eng. Investig., V1, P89
[4]  
[Anonymous], FEASIBILITY REPORT A
[5]   The effects of nozzle aspect ratio and nozzle number on the performance of the Ranque-Hilsch vortex tube [J].
Avci, Mete .
APPLIED THERMAL ENGINEERING, 2013, 50 (01) :302-308
[6]   An experimental study on the design parameters of a counterflow vortex tube [J].
Aydin, Orhan ;
Baki, Muzaffer .
ENERGY, 2006, 31 (14) :2763-2772
[7]   CFD analysis and experimental investigations towards optimizing the parameters of Ranque-Hilsch vortex tube [J].
Behera, U ;
Paul, PJ ;
Kasthurirengan, S ;
Karunanithi, R ;
Ram, SN ;
Dinesh, K ;
Jacob, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (10) :1961-1973
[8]  
Bell S., 1999, A Beginner's Guide to Uncertainty of Measurement
[9]   Rule-based Mamdani-type fuzzy modeling of heating and cooling performances of counter-flow Ranque-Hilsch vortex tubes with different geometric construction for steel [J].
Berber, Adnan ;
Dincer, Kevser ;
Yilmaz, Yusuf ;
Ozen, Dilek Nur .
ENERGY, 2013, 51 :297-304
[10]   Experimental investigation of vortex tube refrigerator with a divergent hot tube [J].
Chang, Kun ;
Li, Qing ;
Zhou, Gang ;
Li, Qiang .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (01) :322-327