Eddy-Current Nondestructive Testing Using an Improved GMR Magnetometer and a Single Wire as Inducer: A FEM Performance Analysis

被引:35
作者
Hamia, Rimond
Cordier, Christophe [1 ]
Saez, Sebastien
Dolabdjian, Christophe
机构
[1] ENSICAEN, GREYC UMR 6072, F-14050 Caen, France
关键词
Crack detection; eddy current; finite-element method; GMR; magnetometer; nondestructive testing; FINITE-ELEMENT-ANALYSIS; GIANT MAGNETORESISTANCE MAGNETOMETER; CURRENT SYSTEM; SURFACE FLAWS; SENSORS; PROBE; COIL; NDE;
D O I
10.1109/TMAG.2010.2052827
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes an efficient nondestructive evaluation (NDE) eddy-current (EC) system using an improved giant magnetoresistance magnetometer (IGMRM) and a simple single wire as inducer. A three-dimensional finite-element method (3-D FEM) was implemented to evaluate the theoretical expected response of the system. The model was based on a modified magnetic vector potential and a reduced magnetic scalar potential, in conducting and nonconducting regions, respectively. The model robustness is established by comparing numerical and experimental results on a given benchmark aluminum plate sample. This efficient 3-D FEM model helps to understand the system performances. Moreover, the excitation frequency effect on the sensed signal is analyzed versus the benchmark sample thickness and the crack sizes. Results are also given and discussed in terms of signal-to-noise ratio.
引用
收藏
页码:3731 / 3737
页数:7
相关论文
共 29 条