The Accuracy of Hemoglobin A1c and Fructosamine Evaluated by Long-Term Continuous Glucose Monitoring in Patients with Type 2 Diabetes Undergoing Hemodialysis

被引:3
作者
Bomholt, Tobias [1 ]
Rix, Marianne [1 ]
Almdal, Thomas [2 ]
Knop, Filip K. [3 ,4 ,5 ,6 ]
Rosthoj, Susanne [7 ]
Heinrich, Niels Sondergaard [6 ]
Jorgensen, Morten B. [1 ]
Larsson, Anders [8 ]
Hilsted, Linda [9 ]
Feldt-Rasmussen, Bo [1 ,4 ]
Hornum, Mads [1 ,4 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Nephrol, Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Dept Endocrinol, Copenhagen, Denmark
[3] Univ Copenhagen, Gentofte Hosp, Ctr Clin Metab Res, Hellerup, Denmark
[4] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[5] Univ Copenhagen, Novo Nordisk Fdn, Fac Hlth & Med Sci, Ctr Basic Metab Res, Copenhagen, Denmark
[6] Steno Diabet Ctr Copenhagen, Gentofte, Denmark
[7] Univ Copenhagen, Fac Hlth & Med Sci, Sect Biostat, Copenhagen, Denmark
[8] Uppsala Univ, Dept Med Sci, Clin Chem, Uppsala, Sweden
[9] Univ Copenhagen, Dept Clin Biochem, Rigshosp, Copenhagen, Denmark
关键词
Hemodialysis; Diabetic nephropathy; Continuous glucose monitoring; Fructosamine; Hemoglobin A1c; BLOOD-CELL SURVIVAL; GLYCATED ALBUMIN; GLYCEMIC CONTROL; AVERAGE GLUCOSE; PLASMA-GLUCOSE; HBA1C; ASSAY;
D O I
10.1159/000519050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The accuracy of hemoglobin A1c (HbA1c) as a glycemic marker in patients with type 2 diabetes (T2D) receiving hemodialysis (HD) remains unknown. To assess accuracy, we compared HbA1c and fructosamine levels with interstitial glucose measured by continuous glucose monitoring (CGM) in patients with T2D receiving HD. Methods: Thirty patients in the HD group and 36 patients in the control group (T2D and an estimated glomerular filtration rate >60 mL/min/1.73 m(2)) completed the study period of 17 weeks. CGM (Ipro2(R), Medtronic) was performed 5 times for periods of up to 7 days (with 4-week intervals) during a 16-week period. HbA1c (mmol/mol), the estimated mean plasma glucose from HbA1c (eMPGA1c [mmol/L]) and fructosamine (mu mol/L) was measured at week 17 and compared with mean sensor glucose levels from CGM. Findings: In the HD group, mean sensor glucose was 1.4 mmol/L (95% confidence interval [CI]: 1.0-1.8) higher than the eMPGA1c, whereas the difference for controls was 0.1 mmol/L (95% CI: -0.1-[0.4]; p < 0.001). Adjusted for mean sensor glucose, HbA1c was lower in the HD group (-7.3 mmol/mol, 95% CI: -10.0-[-4.7]) than in the control group (p < 0.001), with no difference detected for fructosamine (p = 0.64). Discussion: HbA1c evaluated by CGM underestimates plasma glucose levels in patients receiving HD. The underestimation represents a clinical challenge in optimizing glycemic control in the HD population. Fructosamine is unaffected by the factors affecting HbA1c and appears to be more accurate for glycemic monitoring. CGM or fructosamine could thus complement HbA1c in obtaining more accurate glycemic control in this patient group.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 31 条
  • [1] An improved enzymatic assay for glycated serum protein
    Abidin, Dewi
    Liu, Limin
    Dou, Chao
    Datta, Abhijit
    Yuan, Chong
    [J]. ANALYTICAL METHODS, 2013, 5 (10) : 2461 - 2469
  • [2] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [3] Beck Roy W, 2019, J Diabetes Sci Technol, V13, P614, DOI 10.1177/1932296818822496
  • [4] Glucose Management Indicator (GMI): A New Term for Estimating A1C From Continuous Glucose Monitoring
    Bergenstal, Richard M.
    Beck, Roy W.
    Close, Kelly L.
    Grunberger, George
    Sacks, David B.
    Kowalski, Aaron
    Brown, Adam S.
    Heinemann, Lutz
    Aleppo, Grazia
    Ryan, Donna B.
    Riddlesworth, Tonya D.
    Cefalu, William T.
    [J]. DIABETES CARE, 2018, 41 (11) : 2275 - 2280
  • [5] Reduced erythrocyte lifespan measured by chromium-51 in patients with type 2 diabetes undergoing long-term hemodialysis
    Bomholt, Tobias
    Oturai, Peter
    Rix, Marianne
    Almdal, Thomas
    Knop, Filip K.
    Rosthoj, Susanne
    Feldt-Rasmussen, Bo
    Hornum, Mads
    [J]. HEMODIALYSIS INTERNATIONAL, 2021, 25 (02) : 198 - 204
  • [6] The Use of HbA1c, Glycated Albumin and Continuous Glucose Monitoring to Assess Glucose Control in the Chronic Kidney Disease Population Including Dialysis
    Bomholt, Tobias
    Adrian, Therese
    Norgaard, Kirsten
    Ranjan, Ajenthen G.
    Almdal, Thomas
    Larsson, Anders
    Vadstrup, Mette
    Rix, Marianne
    Feldt-Rasmussen, Bo
    Hornum, Mads
    [J]. NEPHRON, 2021, 145 (01) : 14 - 19
  • [7] Danese Elisa, 2015, J Diabetes Sci Technol, V9, P169, DOI 10.1177/1932296814567227
  • [8] International Consensus on Use of Continuous Glucose Monitoring
    Danne, Thomas
    Nimri, Revital
    Battelino, Tadej
    Bergenstal, Richard M.
    Close, Kelly L.
    DeVries, J. Hans
    Garg, Satish
    Heinemann, Lutz
    Hirsch, Irl
    Amiel, Stephanie A.
    Beck, Roy
    Bosi, Emanuele
    Buckingham, Bruce
    Cobelli, Claudio
    Dassau, Eyal
    Doyle, Francis J., III
    Heller, Simon
    Hovorka, Roman
    Jia, Weiping
    Jones, Tim
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Maahs, David
    Murphy, Helen R.
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Saboo, Banshi
    Scharf, Mauro
    Tamborlane, William V.
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2017, 40 (12) : 1631 - 1640
  • [9] Foreword
    Eckardt, Kai-Uwe
    Kasiske, Bertram L.
    [J]. KIDNEY INTERNATIONAL SUPPLEMENTS, 2012, 2 (01) : 7 - 7
  • [10] Evaluation of Turbidimetric Inhibition Immunoassay (TINIA) and HPLC Methods for Glycated Haemoglobin Determination
    Genc, Sema
    Omer, Beyhan
    Aycan-Ustyol, Esra
    Ince, Nurhan
    Bal, Fatih
    Gurdol, Figen
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (06) : 481 - 485