A new material for hip prosthesis without considerable debris release

被引:44
作者
Borruto, Adelina [1 ]
机构
[1] Univ Roma La Sapienza, Dept Chem Engn & Mat, I-00184 Rome, Italy
关键词
Hip; Debris; Wear; Carbon fibre Peek; WEAR DEBRIS; BONE-RESORPTION; ARTHROPLASTY; MACROPHAGES; PARTICLES; JOINTS; METAL; SIZE;
D O I
10.1016/j.medengphy.2010.06.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work presents an alternative bearing surface in the field of total hip replacements. It is composed of a polymer composite polyether-ether-ketone (Peek) as the matrix and a carbon fibre as reinforcement. The authors carried out experimental research in order to investigate the formation of debris caused by tribological coupling of three types of Peek and cobalt chrome alloy. The wear tests (ASTM 99G) have been performed with a pin on disc tribometer in an air environment, under the following conditions: dry, water lubrication using demineralised water as a lubricant and human serum. A method of filtering under vacuum is used to extract the debris from the lubricants used in the tribological test, and the analysis at Scanning Electron Microscopy (SEM) is used to characterize the debris. (c) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:908 / 913
页数:6
相关论文
共 33 条
  • [1] METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS
    AGINS, HJ
    ALCOCK, NW
    BANSAL, M
    SALVATI, EA
    WILSON, PD
    PELLICCI, PM
    BULLOUGH, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) : 347 - 356
  • [2] Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
  • [3] Amstutz HC., 1992, Clin Orthop Rel Res, V276, P7
  • [4] RESORPTION OF BONE BY INFLAMMATORY CELLS DERIVED FROM THE JOINT CAPSULE OF HIP ARTHROPLASTIES
    ATHANASOU, NA
    QUINN, J
    BULSTRODE, CJK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01): : 57 - 62
  • [5] BENTLEY G, 1973, CLIN ORTHOP RELAT R, V95, P127
  • [6] The difference of material wettability as critical factor in the choice of a tribological prosthetic coupling without debris release
    Borruto, A
    Marrelli, L
    Palma, F
    [J]. TRIBOLOGY LETTERS, 2005, 20 (01) : 1 - 10
  • [7] Buly R L, 1992, J Arthroplasty, V7, P315, DOI 10.1016/0883-5403(92)90056-V
  • [8] CAMPBELL P, 1998, T 24 ANN M SOC BIOM, P210
  • [9] Metal versus polyethylene wear particles in total hip replacements
    Doorn, PF
    Campbell, PA
    Amstutz, HC
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) : S206 - S216
  • [10] Endo MM, 2001, BIO-MED MATER ENG, V11, P23