Comparing blind spots of unsedated ultrafine, sedated, and unsedated conventional gastroscopy with and without artificial intelligence: a prospective, single-blind, 3-parallel-group, randomized, single-center trial

被引:63
作者
Chen, Di [1 ,2 ,3 ]
Wu, Lianlian [1 ,2 ,3 ]
Li, Yanxia [1 ,2 ,3 ]
Zhang, Jun [1 ,2 ,3 ]
Liu, Jun [1 ,3 ]
Huang, Li [1 ,2 ,3 ]
Jiang, Xiaoda [1 ,2 ,3 ]
Huang, Xu [1 ,2 ,3 ]
Mu, Ganggang [1 ,2 ,3 ]
Hu, Shan [4 ]
Hu, Xiao [4 ]
Gong, Dexin [1 ,2 ,3 ]
He, Xinqi [1 ,2 ,3 ]
Yu, Honggang [1 ,2 ,3 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Gastroenterol, 99 Zhangzhidong Rd, Wuhan 430060, Hubei, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Key Lab Hubei Prov Digest Syst Dis, Wuhan, Peoples R China
[3] Wuhan Univ, Renmin Hosp, Hubei Prov Clin Res Ctr Digest Dis Minimally Inva, Wuhan, Peoples R China
[4] Wuhan Univ, Sch Resources & Environm Sci, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
UPPER GASTROINTESTINAL ENDOSCOPY; EUROPEAN-SOCIETY; ULTRATHIN EGD; QUALITY; ESOPHAGOGASTRODUODENOSCOPY; PERFORMANCE; THIN;
D O I
10.1016/j.gie.2019.09.016
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: EGD is the most vital procedure for the diagnosis of upper GI lesions. We aimed to compare the performance of unsedated ultrathin transoral endoscopy (U-TOE), unsedated conventional EGD (C-EGD), and sedated C-EGD with or without the use of an artificial intelligence (AI) system. Methods: In this prospective, single-blind, 3-parallel-group, randomized, single-center trial, 437 patients scheduled to undergo outpatient EGD were randomized to unsedated U-TOE, unsedated C-EGD, or sedated C-EGD, and each group was then divided into 2 subgroups: with or without the assistance of an AI system to monitor blind spots during EGD. The primary outcome was the blind spot rate of these 3 groups with the assistance of AI. The secondary outcomes were to compare blind spot rates of unsedated U-TOE, unsedated, and sedated C-EGD with or without the assistance of AI, respectively, and the concordance between AI and the endoscopists' review. Results: The blind spot rate with AI-assisted sedated C-EGD was significantly lower than that of unsedated U-TOE and unsedated C-EGD (3.42% vs 21.77% vs 31.23%, respectively; P < .05). The blind spot rate of the AI subgroup was lower than that of the control subgroup in all 3 groups (sedated C-EGD: 3.42% vs 22.46%, P < .001; unsedated U-TOE: 21.77% vs 29.92%, P < .001; unsedated C-EGD: 31.23% vs 42.46%, P < .001). Conclusions: The blind spot rate of sedated C-EGD was the lowest among the 3 types of EGD, and the addition of AI had a maximal effect on sedated C-EGD.
引用
收藏
页码:332 / +
页数:11
相关论文
共 31 条
  • [11] Use of sedation for routine diagnostic upper gastrointestinal endoscopy:: A European Society of Gastrointestinal Endoscopy survey of National Endoscopy Society members
    Ladas, S. D.
    Aabakken, L.
    Rey, J. -F.
    Nowak, A.
    Zakaria, S.
    Adamonis, K.
    Amrani, N.
    Bergman, J. J. G. H. M.
    Valverde, J. Boix
    Boyacioglu, S.
    Cremers, I.
    Crowe, J.
    Deprez, P.
    Dite, P.
    Eisen, M.
    Eliakim, R.
    Fedorov, E. D.
    Galkova, Z.
    Gyokeres, T.
    Heuss, L. T.
    Husic-Selimovic, A.
    Khediri, F.
    Kuznetsov, K.
    Marek, T.
    Munoz-Navas, M.
    Napoleon, B.
    Niemela, S.
    Pascu, O.
    Perisic, N.
    Pulanic, R.
    Ricci, E.
    Schreiber, F.
    Svendsen, L. B.
    Sweidan, W.
    Sylvan, A.
    Teague, R.
    Tryfonos, M.
    Urbain, D.
    Weber, J.
    Zavoral, M.
    [J]. DIGESTION, 2006, 74 (02) : 69 - 77
  • [12] Deep learning
    LeCun, Yann
    Bengio, Yoshua
    Hinton, Geoffrey
    [J]. NATURE, 2015, 521 (7553) : 436 - 444
  • [13] Diagnosis of thyroid cancer using deep convolutional neural network models applied to sonographic images: a retrospective, multicohort, diagnostic study
    Li, Xiangchun
    Zhang, Sheng
    Zhang, Qiang
    Wei, Xi
    Pan, Yi
    Zhao, Jing
    Xin, Xiaojie
    Qin, Chunxin
    Wang, Xiaoqing
    Li, Jianxin
    Yang, Fan
    Zhao, Yanhui
    Yang, Meng
    Wang, Qinghua
    Zheng, Ming
    Zheng, Xiangqian
    Yang, Xiangming
    Whitlow, Christopher T.
    Gurcan, Metin Nafi
    Zhang, Lun
    Wang, Xudong
    Pasche, Boris C.
    Gao, Ming
    Zhang, Wei
    Chen, Kexin
    [J]. LANCET ONCOLOGY, 2019, 20 (02) : 193 - 201
  • [14] Utilization of Anesthesia Services During Outpatient Endoscopies and Colonoscopies and Associated Spending in 2003-2009
    Liu, Hangsheng
    Waxman, Daniel A.
    Main, Regan
    Mattke, Soeren
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (11): : 1178 - 1184
  • [15] Gastrointestinal Endoscopy Sedation and Monitoring Practices in Spain: A Nationwide Survey in the Year 2014
    Lucendo, Alfredo J.
    Gonzalez-Huix, Ferran
    Tenias, Jose M.
    Lopez-Roses, Leopoldo
    Alonso-Aguirre, Pedro
    Quintero, Enrique
    Munoz-Navas, Miguel
    [J]. ENDOSCOPY, 2015, 47 (04) : 383 - 390
  • [16] The endoscopy Global Rating Scale - Canada: Development and implementation of a quality improvement tool
    MacIntosh, Donald
    Dube, Catherine
    Hollingworth, Roger
    van Zanten, Sander Veldhuyzen
    Daniels, Sandra
    Ghattas, George
    [J]. CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 27 (02) : 74 - 82
  • [17] Mnih V., 2013, Playing atari with deep reinforcement learning
  • [18] Improving the Endoscopic Detection Rate in Patients with Early Gastric Cancer
    Moon, Hee Seok
    [J]. CLINICAL ENDOSCOPY, 2015, 48 (04) : 291 - 296
  • [19] Pethidine dose and female sex as risk factors for nausea after esophagogastroduodenoscopy
    Nishizawa, Toshihiro
    Suzuki, Hidekazu
    Arita, Masahide
    Kataoka, Yosuke
    Fukagawa, Kazushi
    Ohki, Daisuke
    Hata, Keisuke
    Uraoka, Toshio
    Kanai, Takanori
    Yahagi, Naohisa
    Toyoshima, Osamu
    [J]. JOURNAL OF CLINICAL BIOCHEMISTRY AND NUTRITION, 2018, 63 (03) : 230 - 232
  • [20] Ultra-thin caliber endoscopes in daily practice: uses for therapeutic application and beyond on the basis of review of 1028 procedures
    Oterdoom, Leendert H.
    Goet, Jorn C.
    Jacobs, Maarten A. J. M.
    Mulder, Chris J. J.
    [J]. ENDOSCOPY INTERNATIONAL OPEN, 2015, 3 (05) : E400 - E404