Value of computed tomography-based three-dimensional surgical preoperative planning software in total hip arthroplasty with developmental dysplasia of the hip

被引:57
作者
Inoue, Daisuke [1 ]
Kabata, Tamon [1 ]
Maeda, Toru [1 ]
Kajino, Yoshitomo [1 ]
Fujita, Kenji [1 ]
Hasegawa, Kazuhiro [1 ]
Yamamoto, Takashi [1 ]
Tsuchiya, Hiroyuki [1 ]
机构
[1] Kanazawa Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Kanazawa, Ishikawa 9208641, Japan
关键词
ACCURACY; STEM; NAVIGATION;
D O I
10.1007/s00776-014-0683-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Preoperative planning with computed tomography (CT)-based three-dimensional templating has been expanded to achieve more precise placement of hip components. However, few reports have addressed the utility of three-dimensional surgical planning software for secondary osteoarthritis cases. This study therefore investigated the value of CT-based three-dimensional templating software for preoperative planning in primary total hip arthroplasty (THA), with an emphasis on developmental dysplasia of the hip. We performed a retrospective review of 65 hips in 57 patients who underwent cementless primary THA. The preoperative diagnosis was secondary osteoarthritis in all cases due to developmental dysplasia of the hip. All preoperative planning and postoperative evaluations were completed using CT-based three-dimensional templating software. We analyzed the accuracy of stem size prediction and cup size prediction, the reproducibility of preoperative and postoperative stem anteversion, and the absolute error in preoperative and postoperative stem anteversion using CT-based three-dimensional templating software. The sizes of 65 % of the femoral stems (42/65) were estimated exactly, and 98 % (63/65) were accurately estimated to within one stem size. The final acetabular cup sizes corresponded exactly to the preoperatively planned size in 92 % of all cases (62/65). 100 % of the cup size estimates were accurate to within one cup size. There was strong reproducibility of preoperative and postoperative stem anteversion (r = 0.88, P < 0.05). The absolute error in stem anteversion was 4.0A degrees A A +/- A 3.6A degrees. Using CT-based three-dimensional templating software made it possible to achieve reproducible stem anteversion and choose accurate stem and cup sizes in patients with developmental dysplasia of the hip.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 18 条
  • [1] Do Joint Registries Report True Rates of Hip Dislocation?
    Devane, Peter A.
    Wraighte, Philip J.
    Ong, David C. G.
    Horne, J. Geoffrey
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3003 - 3006
  • [2] STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR
    DORR, LD
    FAUGERE, MC
    MACKEL, AM
    GRUEN, TA
    BOGNAR, B
    MALLUCHE, HH
    [J]. BONE, 1993, 14 (03) : 231 - 242
  • [3] Eckrich S G, 1994, J Arthroplasty, V9, P419, DOI 10.1016/0883-5403(94)90053-1
  • [4] The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty
    Gamble, Patrick
    de Beer, Justin
    Petruccelli, Danielle
    Winemaker, Mitchell
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (04) : 529 - 532
  • [5] The prevention of periprosthetic fractures in total hip and knee arthroplasty
    Haddad, FS
    Masri, BA
    Garbuz, DS
    Duncan, CP
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) : 191 - +
  • [6] Surgeon Error in Performing Intraoperative Estimation of Stem Anteversion in Cementless Total Hip Arthroplasty
    Hirata, Masanobu
    Nakashima, Yasuharu
    Ohishi, Masanobu
    Hamai, Satoshi
    Hara, Daisuke
    Iwamoto, Yukihide
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (09) : 1648 - 1653
  • [7] Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: Radiation exposure and cost analysis
    Huppertz, Alexander
    Radmer, Sebastian
    Asbach, Patrick
    Juran, Ralf
    Schwenke, Carsten
    Diederichs, Gerd
    Hamm, Bernd
    Sparmann, Martin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (03) : 406 - 413
  • [8] Comparing the Accuracy of Radiographic Preoperative Digital Templating for a Second- Versus a First-generation THA Stem
    Issa, Kimona
    Pivec, Robert
    Boyd, Bradley
    Harwin, Steven F.
    Wuestemann, Thies
    Nevelos, Jim
    Mont, Michael A.
    [J]. ORTHOPEDICS, 2012, 35 (12) : 1028 - 1034
  • [9] Strict component positioning is necessary in hip resurfacing
    Kajino, Yoshitomo
    Kabata, Tamon
    Maeda, Toru
    Iwai, Shintaro
    Kuroda, Kazunari
    Fujita, Kenji
    Tsuchiya, Hiroyuki
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (02) : 290 - 297
  • [10] Evaluation of the Accuracy of Computed Tomography-Based Navigation for Femoral Stem Orientation and Leg Length Discrepancy
    Kitada, Makoto
    Nakamura, Nobuo
    Iwana, Daiki
    Kakimoto, Akihiro
    Nishii, Takashi
    Sugano, Nobuhiko
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (05) : 674 - 679