Optical fibers in instrumental UV-analytics

被引:2
作者
Klein, Karl-Friedrich [1 ]
Mannhardt, Joachim [2 ]
Belz, Mathias [3 ]
Gonschior, Cornell [1 ]
Eckhardt, Hanns S. [2 ]
机构
[1] Univ Appl Sci Giessen Friedberg, W Leuschner Str 13, D-61169 Friedberg, Germany
[2] J&M Analyt AG, D-73457 Esslingen, Germany
[3] World Precis Instruments Inc, Sarasota, FL 34240 USA
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS IX | 2009年 / 7173卷
关键词
UV-silica fibers; Optical UV-properties; long-term stability; instrumental analytics; cleaning-in-process;
D O I
10.1117/12.818663
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Physical and optical properties of optical fibers have improved over recent years significantly. Especially classic UV detection techniques in traditional chemistry, HPLC and dissolution testing rely more and more on fiber optic light guiding techniques to transport light to and from a sample simplifying the design of such detection techniques. An overview on the current status of UV-fiber optical properties will be given in this work. Especially, the reduction of UV-defects in the 215 nm wavelength region leading to a lower drift in the whole system, will be discussed. However, these are not the only parameters of interest in a fiber-optic system. For process control or instrumental analytics, the long-term stability including drift and noise must be determined. This requires stringent fiber test procedures similar to light-sources, connectors and complete detector systems. Further, white-light interference between optical interfaces of a fiber optic detection system due to axial movement, degradation of components and temperature often reduces system stability and must be considered. Finally, a cleaning-in-process of a fiber optic immersion probe will be introduced as a further step of system improvement.
引用
收藏
页数:7
相关论文
共 21 条
[1]  
BELZ M, 1998, THESIS CITY U LONDON
[2]   Quality control of UV resistant fibers for 200-300 nm spectroscopic applications [J].
Belz, Mathias ;
Eckhardt, Hanns-S. ;
Gonschior, Cornell P. ;
Nelson, Gary ;
Klein, Karl-F. .
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VIII, 2008, 6852
[3]  
DEMTRODER W, 1977, GRUNDLAGEN TECHNIKEN, P63
[4]   Fibre-optic UV systems for gas and vapour analysis [J].
Eckhardt, Hanns Simon ;
Klein, Karl-Friedrich ;
Spangenberg, Bernd ;
Sun, Tong ;
Grattan, Kenneth T. V. .
THIRD INTERNATIONAL CONFERENCE ON OPTICAL AND LASER DIAGNOSTICS (ICOLAD 2007), 2007, 85
[5]  
Friebele E.J., 1979, Treatise on Material Science and Technology, V17, P257
[6]   DEFECT STRUCTURE OF GLASSES - SOME OUTSTANDING QUESTIONS IN REGARD TO VITREOUS SILICA [J].
GRISCOM, DL .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1985, 73 (1-3) :51-77
[7]  
*HER NOBL GMBH HAN, 2002, BROCH DEUT LAMPS
[8]  
Kao K.C., 1996, P I ELECT ENG, V113, P1151
[9]  
KHALILOV VK, 2006, SPIE P BIOS 06, V6083
[10]   High NA-fibers: silica-based fibers for new applications [J].
Klein, KF ;
Eckhardt, HS ;
Vincze, C ;
Grimm, S ;
Kirchhof, J ;
Kobelke, J ;
Clarkin, J ;
Nelson, G ;
Giessen-Friedberg, F .
OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS V, 2005, 5691 :30-41