The use of a personal glucose meter for detecting procalcitonin through glucose encapsulated within liposomes

被引:22
作者
Alshawawreh, Fida'a [1 ]
Lisi, Fabio [1 ]
Ariotti, Nicholas [1 ]
Bakthavathsalam, Padmavathy [1 ]
Benedetti, Tania [1 ]
Tilley, Richard D. [2 ]
Gooding, J. Justin [3 ,4 ]
机构
[1] Univ New South Wales, Sch Chem, Sydney, NSW 2052, Australia
[2] Univ New South Wales, Mark Wainwright Analyt Ctr, Electron Microscope Unit Microscopy Australia Nod, Sydney, NSW 2052, Australia
[3] Univ New South Wales, Australian Ctr NanoMed, Sch Chem, Sydney, NSW 2052, Australia
[4] Univ New South Wales, ARC Ctr Excellence Convergent Bionano Sci & Techn, Sydney, NSW 2052, Australia
基金
英国医学研究理事会;
关键词
SIGNAL AMPLIFICATION; SEPSIS; ASSAY;
D O I
10.1039/c9an01519a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a glucose meter-based immunosensing platform is developed that allows the quantification of procalcitonin (PCT) in whole blood samples. PCT is a biomarker for sepsis and its early detection would improve the safety of the patient, as the diagnostic process will be easier and faster. The method employs liposomes with encapsulated glucose as a signal generation tag, which are then used in a sandwich immunoassay by conjugating an antibody to the liposome. The optimal liposomes' size and concentration of encapsulated glucose is determined experimentally to be 200 nm and 27.8 mM, respectively. Upon the addition of a surfactant (Triton X-100), the glucose is released and a signal is detected with a personal glucose meter (PGM). This signal is directly proportional to the concentration of the PCT in the sample. The dynamic range of the assay developed was 0.153-15.38 nM, and could allow the detection of PCT as low as 0.15 nM. The assay showed a high selectivity toward PCT against other proteins such as C-reactive protein and human serum albumin and good reproducibility. This assay was able to quantitatively determine the amount of PCT in whole blood samples at clinically-relevant concentrations.
引用
收藏
页码:6225 / 6230
页数:6
相关论文
共 19 条
[1]   Four Assay Designs and On-Chip Calibration: Gadgets for a Sepsis Protein Array [J].
Buchegger, Patricia ;
Preininger, Claudia .
ANALYTICAL CHEMISTRY, 2014, 86 (06) :3174-3180
[2]  
Chakraborty S., DO WE NEED PROCALCIT
[3]  
Christ-Crain M, 2005, SWISS MED WKLY, V135, P451
[4]  
DELLINGER RP, 2013, INTENS CARE MED, V39, P165, DOI DOI 10.1007/s00134-012-2769-8
[5]   Electrochemical immunoassay for procalcitonin antigen detection based on signal amplification strategy of multiple nanocomposites [J].
Fang, Yi-Shan ;
Wang, Hai-Ying ;
Wang, Li-Shi ;
Wang, Ju-Fang .
BIOSENSORS & BIOELECTRONICS, 2014, 51 :310-316
[6]   Diagnostic value of procalcitonin, interleukin-6, and interleukin-8 in critically ill patients admitted with suspected sepsis [J].
Harbarth, S ;
Holeckova, K ;
Froidevaux, C ;
Pittet, D ;
Ricou, B ;
Grau, GE ;
Vadas, L ;
Pugin, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (03) :396-402
[7]   Evaluation of procalcitonin with liquid-phase binding assay in hematological malignancy [J].
Koya, Junji ;
Nannya, Yasuhito ;
Kurokawa, Mineo .
CLINICA CHIMICA ACTA, 2012, 413 (19-20) :1633-1636
[8]   C60 carboxyfullerene-based functionalised nanohybrids as signal-amplifying tags for the ultrasensitive electrochemical detection of procalcitonin [J].
Li, Ping ;
Zhang, Wenchao ;
Zhou, Xuan ;
Zhang, Lun .
CLINICAL BIOCHEMISTRY, 2015, 48 (03) :156-161
[9]   An ultrasensitive ELISA method for the detection of procalcitonin based on magnetic beads and enzyme-antibody labeled gold nanoparticles [J].
Liao, Tao ;
Yuan, Fang ;
Yu, Haoyang ;
Li, Zigang .
ANALYTICAL METHODS, 2016, 8 (07) :1577-1585
[10]   Procalcitonin sensitive detection based on graphene-gold nanocomposite film sensor platform and single-walled carbon nanohorns/hollow Pt chains complex as signal tags [J].
Liu, Fei ;
Xiang, Guiming ;
Yuan, Ruo ;
Chen, Xuemei ;
Luo, Fukang ;
Jiang, Dongneng ;
Huang, Shaoguang ;
Li, Yi ;
Pu, Xiaoyun .
BIOSENSORS & BIOELECTRONICS, 2014, 60 :210-217