Electrochemical Sensing of Arsenic Ions Using a Covalently Functionalized Benzotriazole-Reduced Graphene Oxide-Modified Screen-Printed Carbon Electrode

被引:10
|
作者
Gunasekaran, Balu Mahendran [1 ,2 ]
Rayappan, John Bosco Balaguru [3 ,4 ]
Rajendran, Ganesh Kumar [6 ]
Gopalakrishnan, Gopu [7 ]
Nesakumar, Noel [4 ,5 ]
Muthiah, Senthilkumar [8 ]
Sivanesan, Jothi Ramalingam [1 ,2 ]
机构
[1] AVVM Sri Pushpam Coll Autonomous, PG & Res Dept Chem, Thanjavur 613503, Tamil Nadu, India
[2] Bharathidasan Univ, Tiruchirappalli, India
[3] SASTRA Deemed Univ, Sch Elect & Elect Engn, Thanjavur 613401, Tamil Nadu, India
[4] SASTRA Deemed Univ, Ctr Nanotechnol & Adv Biomat CeNTAB, Thanjavur 613401, Tamil Nadu, India
[5] SASTRA Deemed Univ, Sch Chem & Biotechnol, Thanjavur 613401, Tamil Nadu, India
[6] Pachaiyappas Coll, PG & Res Dept Chem, Chennai 600030, Tamil Nadu, India
[7] Alagappa Univ, Dept Ind Chem, Karaikkudi 630003, Tamil Nadu, India
[8] Alagappa Chettiar Govt Coll Engn & Technol, Dept Chem, Karaikkudi 630003, Tamil Nadu, India
来源
CHEMISTRYSELECT | 2022年 / 7卷 / 25期
关键词
green reduction; graphene; benzotriazole; arsenic; differential pulse voltammetry; GREEN SYNTHESIS; NANOCOMPOSITE; COMPOSITE; AS(III); SENSOR; NANOPARTICLE; REDUCTION; FILM; FABRICATION; MOLECULES;
D O I
10.1002/slct.202201169
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein, Tecoma stans (TS) flower extract was used as an efficient green reducing agent for graphene oxide (GO) to produce reduced graphene oxide (rGO) for the first time. The organic heterocyclic benzotriazole (BTA) was incorporated onto the rGO surface through a nucleophilic substitution reaction to produce covalently bonded BTA-rGO. The prepared materials were analyzed by UV-visible spectroscopy, powder X-ray diffraction measurements (XRD), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, and Scanning Electron Microscopy (SEM). A screen-printed carbon electrode (SPCE) was modified with BTA-rGO. The fabricated electrode was electrochemically analyzed by using K-3[Fe (CN)(6)] as a redox probe. To evaluate the sensing ability of BTA-rGO/SPCE electrode towards arsenic ions using differential pulse voltammetry (DPV) and amperometry techniques. The BTA functional was play the major role in significant improving the conductivity and sensitivity of the designed electrode. The BTA-rGO/SPCE modified electrode demonstrates voltammetric determination of As3+ ions with a limit of detection, high sensitivity, and linear range values of 2.89 nM, 1.8 mu A nM(-1), and 2-40 nM, respectively. Furthermore, all of these impressive results indicate that BTA-rGO can be used as an electrode-material with capability for electrochemical arsenic sensors. The fabricated sensors showed repeatability and reproducibility in this study.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Electrochemical Determination of Hydrazine Based on Modified Screen-Printed Carbon Electrode
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Hamidian, Hooshang
    Mousazadeh, Farideh
    Emambakhsh, Fatemeh
    Sajadi, Pari-Sima
    Allahabadi, Hossein
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (01)
  • [22] Sensitive Detection of Rosmarinic Acid Using Peptide-Modified Graphene Oxide Screen-Printed Carbon Electrode
    Munteanu, Irina Georgiana
    Gradinaru, Vasile Robert
    Apetrei, Constantin
    NANOMATERIALS, 2022, 12 (19)
  • [23] A Voltammetric Sensor Based on Chemically Reduced Graphene Oxide-Modified Screen-Printed Carbon Electrode for the Simultaneous Analysis of Uric Acid, Ascorbic Acid and Dopamine
    Kanyong, Prosper
    Rawlinson, Sean
    Davis, James
    CHEMOSENSORS, 2016, 4 (04):
  • [24] Electrochemical determination of sulfur-containing amino acid on Screen-Printed Carbon Electrode modified with Graphene Oxide
    Sasikumar, Ragu
    Ranganathan, Palraj
    Chen, Shen-Ming
    Kavitha, Thavuduraj
    Lee, Shih-Yi
    Chen, Tse-Wei
    Chang, Wen-Han
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (05): : 4077 - 4085
  • [25] Electrochemical Determination of Dopamine Using a Poly(3,4-Ethylenedioxythiophene)-Reduced Graphene Oxide-Modified Glassy Carbon Electrode
    Cogal, Sadik
    ANALYTICAL LETTERS, 2018, 51 (11) : 1666 - 1679
  • [26] Copper(II) oxide-modified screen-printed carbon electrode for electrochemical detection of tuberculosis and mycobacterial infections treating drugs: rifampicin
    Qiu, Shengzhou
    Wu, Chenxi
    Akter, Sima
    Hong, Shaoli
    Liu, Huihong
    Mahmud, Sakil
    MONATSHEFTE FUR CHEMIE, 2024, 155 (11): : 1071 - 1083
  • [27] Sensitive Electrochemical Detection of Caffeic Acid using a Carboxyl-Functionalized Reduced Graphene Oxide-Modified Glassy Carbon Electrode (ERGO-COOH/GCE)
    Zhou, Ming
    Xu, Yong
    Zhong, Rong
    Wang, Yurong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (07): : 1 - 15
  • [28] 2-Aminotrimesic Acid-Functionalized Graphene Oxide-Modified Screen-Printed Electrodes for Sensitive Electrochemical Detection of Cardiac Marker Troponin I
    Gupta, Arushi
    Kumar Sharma, Sandeep
    L. Sharma, Amit
    Deep, Akash
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2021, 218 (13):
  • [29] Electrodeposited rGO/AuNP/MnO2 Nanocomposite-Modified Screen-Printed Carbon Electrode for Sensitive Electrochemical Sensing of Arsenic(III) in Water
    Wu, Yanqing
    Zhang, Tao
    Su, Lishen
    Wu, Xiaoping
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [30] Nickel nanoparticle-chitosan-reduced graphene oxide-modified screen-printed electrodes for enzyme-free glucose sensing in portable microfluidic devices
    Yang, Jiang
    Yu, Ji-Hyuk
    Strickler, J. Rudi
    Chang, Woo-Jin
    Gunasekaran, Sundaram
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 530 - 538