Targeting Accuracy of the Subthalamic Nucleus in Deep Brain Stimulation Surgery: Comparison Between 3 T T2-Weighted Magnetic Resonance Imaging and Microelectrode Recording Results

被引:17
|
作者
Nowacki, Andreas [1 ]
Debove, Ines [2 ]
Fiechter, Michael [1 ]
Rossi, Frederic [1 ]
Oertel, Markus Florian [1 ]
Wiest, Roland [3 ]
Schupbach, Michael [2 ]
Pollo, Claudio [1 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurosurg, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Dept Diagnost & Intervent Neuroradiol, Bern, Switzerland
关键词
DBS; Microelectrode recording; Targeting accuracy; ADVANCED PARKINSONS-DISEASE; MRI; LOCALIZATION; ELECTRODE; IMPLANTATION; LOCATIONS; DYSTONIA; OUTCOMES;
D O I
10.1093/ons/opx175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Targeting accuracy in deep brain stimulation (DBS) surgery can be defined as the level of accordance between selected and anatomic real target reflected by characteristic electrophysiological results of microelectrode recording (MER). OBJECTIVE: To determine the correspondence between the preoperative predicted target based on modern 3-T magnetic resonance imaging (MRI) and intraoperative MER results separately on the initial and consecutive second side of surgery. METHODS: Retrospective cohort study of 86 trajectories of DBS electrodes implanted into the subthalamic nucleus (STN) of patients with Parkinson's disease. The entrance point of the electrode into the STN and the length of the electrode trajectory crossing the STN were determined by intraoperative MER findings and 3 T T2-weighted magnetic resonance images with 1-mm slice thickness. RESULTS: Average difference between MRI- and MER-based trajectory lengths crossing the STN was 0.28 +/- 1.02 mm (95% CI: -0.51 to -0.05 mm). There was a statistically significant difference between the MRI- and MER-based entry points on the initial and second side of surgery (P = .04). Forty-three percent of the patients had a difference of more than +/- 1 mm of the MRI-based-predicted and the MER-based-determined entry points into the STN with values ranging from -3.0 to +/- 4.5 mm. CONCLUSION: STN MRI-based targeting is accurate in the majority of cases on the first and second side of surgery. in 43% of implanted electrodes, we found a relevant deviation of more than 1 mm, supporting the concept of MER as an important tool to guide and optimize targeting and electrode placement.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [41] T1-or T2-weighted magnetic resonance imaging: what is the best choice to evaluate atrophy of the hippocampus?
    Fischbach-Boulanger, C.
    Fitsiori, A.
    Noblet, V.
    Baloglu, S.
    Oesterle, H.
    Draghici, S.
    Philippi, N.
    Duron, E.
    Hanon, O.
    Dietemann, J. -L.
    Blanc, F.
    Kremer, S.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 (05) : 775 - 781
  • [42] Motor and Nonmotor Circuitry Activation Induced by Subthalamic Nucleus Deep Brain Stimulation in Patients With Parkinson Disease: Intraoperative Functional Magnetic Resonance Imaging for Deep Brain Stimulation
    Knight, Emily J.
    Testini, Paola
    Min, Hoon-Ki
    Gibson, William S.
    Gorny, Krzysztof R.
    Favazza, Christopher P.
    Felmlee, Joel P.
    Kim, Inyong
    Welker, Kirk M.
    Clayton, Daniel A.
    Klassen, Bryan T.
    Chang, Su-youne
    Lee, Kendall H.
    MAYO CLINIC PROCEEDINGS, 2015, 90 (06) : 773 - 785
  • [43] Defining the anterior nucleus of the thalamus (ANT) as a deep brain stimulation target in refractory epilepsy: Delineation using 3 T MRI and intraoperative microelectrode recording
    Mottonen, T.
    Katisko, J.
    Haapasalo, J.
    Tahtinen, T.
    Kiekara, T.
    Kahara, V.
    Peltola, J.
    Ohman, J.
    Lehtimaki, K.
    NEUROIMAGE-CLINICAL, 2015, 7 : 823 - 829
  • [44] An observational study of T2-weighted white matter hyperintensities on magnetic resonance imaging of the internal auditory meatus and brain: ignore or not?
    Huang, X.
    Grimmond, N.
    Kontorinis, G.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2021, 135 (11) : 964 - 969
  • [45] Assessing Accuracy of the Magnetic Resonance Imaging-Computed Tomography Fusion Images to Evaluate the Electrode Positions in Subthalamic Nucleus After Deep-Brain Stimulation
    Shin, Masahiro
    Penholate, Marcello Faria
    Lefaucheur, Jean-Pascal
    Gurruchaga, Jean-Marc
    Brugieres, Pierre
    Nguyen, Jean-Paul
    NEUROSURGERY, 2010, 66 (06) : 1193 - 1202
  • [46] Imaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance
    Bloch, Lars Olgaard
    Hansen, Anne Yoon Krogh Grondal
    Pedersen, Steen Fjord
    Honge, Jesper Langhoff
    Kim, Won Yong
    Hansen, Esben Sovso Szocska
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [47] Elucidating the aberrant brain regions in bipolar disorder using T1-weighted/T2-weighted magnetic resonance ratio images
    Ishida, Takuya
    Donishi, Tomohiro
    Iwatani, Jun
    Yamada, Shinichi
    Takahashi, Shun
    Ukai, Satoshi
    Shinosaki, Kazuhiro
    Terada, Masaki
    Kaneoke, Yoshiki
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2017, 263 : 76 - 84
  • [48] Novel monodisperse FePt nanocomposites for T2-weighted magnetic resonance imaging: biomedical theranostics applications
    Chang, Zhi-Xuan
    Li, Chien-Hsiu
    Chang, Yu-Chan
    Huang, Chi-Ying F.
    Chan, Ming-Hsien
    Hsiao, Michael
    NANOSCALE ADVANCES, 2022, 4 (02): : 377 - 386
  • [49] Exploring Hypoxia in Prostate Cancer With T2-weighted Magnetic Resonance Imaging Radiomics and Pimonidazole Scoring
    Leech, Michelle
    Leijenaar, Ralph T. H.
    Hompland, Tord
    Gaffney, John
    Lyng, Heidi
    Marignol, Laure
    ANTICANCER RESEARCH, 2023, 43 (01) : 351 - 357
  • [50] Myometrial invasion and overall staging of endometrial carcinoma: assessment using fusion of T2-weighted magnetic resonance imaging and diffusion-weighted magnetic resonance imaging
    Guo, Yu
    Wang, Ping
    Wang, Penghui
    Gao, Wei
    Li, Fenge
    Yang, Xueling
    Ni, Hongyan
    Shen, Wen
    Guo, Zhi
    ONCOTARGETS AND THERAPY, 2017, 10 : 5937 - 5943