Targeting Accuracy of the Subthalamic Nucleus in Deep Brain Stimulation Surgery: Comparison Between 3 T T2-Weighted Magnetic Resonance Imaging and Microelectrode Recording Results

被引:17
|
作者
Nowacki, Andreas [1 ]
Debove, Ines [2 ]
Fiechter, Michael [1 ]
Rossi, Frederic [1 ]
Oertel, Markus Florian [1 ]
Wiest, Roland [3 ]
Schupbach, Michael [2 ]
Pollo, Claudio [1 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurosurg, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Dept Diagnost & Intervent Neuroradiol, Bern, Switzerland
关键词
DBS; Microelectrode recording; Targeting accuracy; ADVANCED PARKINSONS-DISEASE; MRI; LOCALIZATION; ELECTRODE; IMPLANTATION; LOCATIONS; DYSTONIA; OUTCOMES;
D O I
10.1093/ons/opx175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Targeting accuracy in deep brain stimulation (DBS) surgery can be defined as the level of accordance between selected and anatomic real target reflected by characteristic electrophysiological results of microelectrode recording (MER). OBJECTIVE: To determine the correspondence between the preoperative predicted target based on modern 3-T magnetic resonance imaging (MRI) and intraoperative MER results separately on the initial and consecutive second side of surgery. METHODS: Retrospective cohort study of 86 trajectories of DBS electrodes implanted into the subthalamic nucleus (STN) of patients with Parkinson's disease. The entrance point of the electrode into the STN and the length of the electrode trajectory crossing the STN were determined by intraoperative MER findings and 3 T T2-weighted magnetic resonance images with 1-mm slice thickness. RESULTS: Average difference between MRI- and MER-based trajectory lengths crossing the STN was 0.28 +/- 1.02 mm (95% CI: -0.51 to -0.05 mm). There was a statistically significant difference between the MRI- and MER-based entry points on the initial and second side of surgery (P = .04). Forty-three percent of the patients had a difference of more than +/- 1 mm of the MRI-based-predicted and the MER-based-determined entry points into the STN with values ranging from -3.0 to +/- 4.5 mm. CONCLUSION: STN MRI-based targeting is accurate in the majority of cases on the first and second side of surgery. in 43% of implanted electrodes, we found a relevant deviation of more than 1 mm, supporting the concept of MER as an important tool to guide and optimize targeting and electrode placement.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [31] 3D segmentation of annulus fibrosus and nucleus pulposus from T2-weighted magnetic resonance images
    Castro-Mateos, Isaac
    Pozo, Jose M.
    Eltes, Peter E.
    Del Rio, Luis
    Lazary, Aron
    Frangi, Alejandro F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (24) : 7847 - 7864
  • [32] Extracapsular Extension of Prostate Cancer: Diagnostic Value of Combined Multiparametric Magnetic Resonance Imaging and Isovoxel 3-Dimensional T2-Weighted Imaging at 1.5 T
    Itatani, Ryo
    Namimoto, Tomohiro
    Takaoka, Hiroko
    Katahira, Kazuhiro
    Morishita, Syoji
    Kitani, Kosuke
    Hamada, Yasuyuki
    Kitaoka, Mitsuhiko
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (01) : 37 - 43
  • [33] T2-weighted turbo spin-echo magnetic resonance imaging of canine brain anatomy at 1.5T, 3T, and 7T field strengths
    Jacqmot, Olivier
    Van Thielen, Bert
    Hespel, Adrien-Maxence
    Luijten, Peter R.
    de Mey, Johan
    Van Binst, Anne
    Provyn, Steven
    Tresignie, Jonathan
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2022, 305 (01): : 222 - 233
  • [34] T2-Weighted Endorectal Magnetic Resonance Imaging of Prostate Cancer after External Beam Radiation Therapy
    Westphalen, Antonio C.
    Kurhanewicz, John
    Cunha, Rui M. G.
    Hsu, I-Chow
    Kornak, John
    Zhao, Shoujun
    Coakley, Fergus V.
    INTERNATIONAL BRAZ J UROL, 2009, 35 (02): : 171 - 180
  • [35] T2-weighted magnetic resonance imaging characterization of prolactinomas and association with their response to dopamine agonists
    M. C. Burlacu
    D. Maiter
    T. Duprez
    E. Delgrange
    Endocrine, 2019, 63 : 323 - 331
  • [36] T2-weighted magnetic resonance imaging characterization of prolactinomas and association with their response to dopamine agonists
    Burlacu, M. C.
    Maiter, D.
    Duprez, T.
    Delgrange, E.
    ENDOCRINE, 2019, 63 (02) : 323 - 331
  • [37] Intensity of prolactinoma on T2-weighted magnetic resonance imaging: towards another gender difference
    Kreutz, Julie
    Vroonen, Laurent
    Cattin, Francoise
    Petrossians, Patrick
    Thiry, Albert
    Rostomyan, Liliya
    Tshibanda, Luaba
    Beckers, Albert
    Bonneville, Jean-Francois
    NEURORADIOLOGY, 2015, 57 (07) : 679 - 684
  • [38] Stability of polyelectrolyte-coated iron nanoparticles for T2-weighted magnetic resonance imaging
    McGrath, Andrew J.
    Dolan, Ciaran
    Cheong, Soshan
    Herman, David A. J.
    Naysmith, Briar
    Zong, Fangrong
    Galvosas, Petrik
    Farrand, Kathryn J.
    Hermans, Ian F.
    Brimble, Margaret
    Williams, David E.
    Jin, Jianyong
    Tilley, Richard D.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 439 : 251 - 258
  • [39] Deep learning can reduce acquisition time of T2-weighted image in brain imaging
    El-Saeed Abou-ELMagd, Eman Hassan
    Elmogy, Sabry Alameldin
    Abdelzaher, Dina Gamal
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2025, 56 (01)
  • [40] Verification of measurements of lumbar spinal dimensions in T1-and T2-weighted magnetic resonance imaging sequences
    Cheung, Jason Pui-Yin
    Shigematsu, Hideki
    Cheung, Kenneth Man-Chee
    SPINE JOURNAL, 2014, 14 (08) : 1476 - 1483