Targeting Accuracy of the Subthalamic Nucleus in Deep Brain Stimulation Surgery: Comparison Between 3 T T2-Weighted Magnetic Resonance Imaging and Microelectrode Recording Results

被引:17
|
作者
Nowacki, Andreas [1 ]
Debove, Ines [2 ]
Fiechter, Michael [1 ]
Rossi, Frederic [1 ]
Oertel, Markus Florian [1 ]
Wiest, Roland [3 ]
Schupbach, Michael [2 ]
Pollo, Claudio [1 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurosurg, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Dept Diagnost & Intervent Neuroradiol, Bern, Switzerland
关键词
DBS; Microelectrode recording; Targeting accuracy; ADVANCED PARKINSONS-DISEASE; MRI; LOCALIZATION; ELECTRODE; IMPLANTATION; LOCATIONS; DYSTONIA; OUTCOMES;
D O I
10.1093/ons/opx175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Targeting accuracy in deep brain stimulation (DBS) surgery can be defined as the level of accordance between selected and anatomic real target reflected by characteristic electrophysiological results of microelectrode recording (MER). OBJECTIVE: To determine the correspondence between the preoperative predicted target based on modern 3-T magnetic resonance imaging (MRI) and intraoperative MER results separately on the initial and consecutive second side of surgery. METHODS: Retrospective cohort study of 86 trajectories of DBS electrodes implanted into the subthalamic nucleus (STN) of patients with Parkinson's disease. The entrance point of the electrode into the STN and the length of the electrode trajectory crossing the STN were determined by intraoperative MER findings and 3 T T2-weighted magnetic resonance images with 1-mm slice thickness. RESULTS: Average difference between MRI- and MER-based trajectory lengths crossing the STN was 0.28 +/- 1.02 mm (95% CI: -0.51 to -0.05 mm). There was a statistically significant difference between the MRI- and MER-based entry points on the initial and second side of surgery (P = .04). Forty-three percent of the patients had a difference of more than +/- 1 mm of the MRI-based-predicted and the MER-based-determined entry points into the STN with values ranging from -3.0 to +/- 4.5 mm. CONCLUSION: STN MRI-based targeting is accurate in the majority of cases on the first and second side of surgery. in 43% of implanted electrodes, we found a relevant deviation of more than 1 mm, supporting the concept of MER as an important tool to guide and optimize targeting and electrode placement.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [21] Can We Rely on Susceptibility-Weighted Imaging for Subthalamic Nucleus Identification in Deep Brain Stimulation Surgery?
    Bot, Maarten
    Bour, Lo
    de Bie, Rob M.
    Contarino, Maria Fiorella
    Schuurman, Richard
    van den Munckhof, Pepijn
    NEUROSURGERY, 2016, 78 (03) : 353 - 359
  • [22] Direct targeting of globus pallidus internus for deep brain stimulation using susceptibility-weighted magnetic resonance imaging
    Guner, Yahya E.
    Eray, Halit A.
    Akbostanci, Muhittin C.
    Savas, Ali
    CHIRURGIA-ITALY, 2024, 37 (04): : 247 - 256
  • [23] Myocardial area at risk and salvage measured by T2-weighted cardiovascular magnetic resonance: Reproducibility and comparison of two T2-weighted protocols
    Lonborg, Jacob
    Vejlstrup, Niels
    Mathiasen, Anders B.
    Thomsen, Carsten
    Jensen, Jan S.
    Engstrom, Thomas
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [24] Abnormal T2-Weighted MRI Signal Surrounding Leads in a Subset of Deep Brain Stimulation Patients
    Englot, Dario J.
    Glastonbury, Christine M.
    Larson, Paul S.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2011, 89 (05) : 311 - 317
  • [25] Toxicity and T2-Weighted Magnetic Resonance Imaging Potentials of Holmium Oxide Nanoparticles
    Atabaev, Timur Sh.
    Shin, Yong Cheol
    Song, Su-Jin
    Han, Dong-Wook
    Nguyen Hoa Hong
    NANOMATERIALS, 2017, 7 (08):
  • [26] High-Resolution 3-Dimensional T2☆-Weighted Angiography (HR 3-D SWAN): An Optimized 3-T Magnetic Resonance Imaging Sequence for Targeting the Subthalamic Nucleus
    Lefranc, Michel
    Derrey, Stephane
    Merle, Philippe
    Tir, Melissa
    Constans, Jean-Marc
    Montpellier, Dominique
    Macron, Jean Michel
    Le Gars, Daniel
    Peltier, Johan
    Baledentt, Olivier
    Krystkowiak, Pierre
    NEUROSURGERY, 2014, 74 (06) : 615 - 626
  • [27] Prostate Cancer: Comparison of 3D T2-Weighted With Conventional 2D T2-Weighted Imaging for Image Quality and Tumor Detection
    Rosenkrantz, Andrew B.
    Neil, Jeffry
    Kong, Xiangtian
    Melamed, Jonathan
    Babb, James S.
    Taneja, Samir S.
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : 446 - 452
  • [28] Can We Rely on Susceptibility-Weighted Imaging (SWI) for Subthalamic Nucleus Identification in Deep Brain Stimulation Surgery?
    Keuken, Max C.
    Schaefer, Andreas
    Forstmann, Birte U.
    NEUROSURGERY, 2016, 79 (06) : E945 - E946
  • [29] Deep-learning-based segmentation of perivascular spaces on T2-Weighted 3T magnetic resonance images
    Cai, Die
    Pan, Minmin
    Liu, Chenyuan
    He, Wenjie
    Ge, Xinting
    Lin, Jiaying
    Li, Rui
    Liu, Mengting
    Xia, Jun
    FRONTIERS IN AGING NEUROSCIENCE, 2024, 16
  • [30] Does Probe's Eye Subthalamic Nucleus Length on T2W MRI Correspond with Microelectrode Recording in Patients with Deep Brain Stimulation for Advanced Parkinson's Disease?
    Kocabicak, Ersoy
    Aygun, Dursun
    Ozaydin, Ilkay
    Jahanshahi, Ali
    Tan, Sonny K. H.
    Onar, Musa
    Boke, Omer
    Kurt, Murat
    Guz, Hatice
    Terzi, Murat
    Alptekin, Onur
    Temel, Yasin
    TURKISH NEUROSURGERY, 2013, 23 (05) : 658 - 665