A non-equal fragment model of a water-wall in a supercritical boiler

被引:19
|
作者
Wang, Jizhou [1 ]
Zhang, Yanping [1 ]
Li, Yu [1 ]
Huang, Shuhong [1 ]
机构
[1] Huazhong Uni Sci & Tech, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-equal fragment model; Parameter distribution; Water-wall; Boiler; POWER-PLANT; SIMULATION; OPTIMIZATION; COMBUSTION; FURNACE;
D O I
10.1016/j.joei.2014.05.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a non-equal fragment model is developed to investigate the heat and mass transfer of a water-wall in a supercritical boiler. In this model, the water-wall has been divided into several fragments and has been coupled with a boiler furnace model, which is divided into seven compartments based on the position of the burners. The model was validated using data from a 600 MW supercritical boiler in China. The agreement between the calculated response and the operation data is satisfactory. Compared with conventional methods, the non-equal fragment model provides a more reliable heat distribution and a more adaptive response under different burners' conditions. The steam thermodynamic distributions along the vertical direction have been meticulously calculated and will be helpful for the metal temperature prediction, performance estimation and energy-saving potential analysis. (C) 2014 Energy Institute. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 29 条
  • [21] Analysis on the Safety of the Water Wall in a 350MW Supercritical CFB Boiler Under Electricity Failure Condition
    Deng B.
    Zhang M.
    Li S.
    Lyu J.
    Yang H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (16): : 4799 - 4807
  • [22] Heat sensitivity of vertical water wall at low mass velocity in supercritical pressure W-shaped flame boiler
    Wang, Weishu
    Zhu, Xiaojing
    Bi, Qincheng
    Wu, Gang
    Huang, Jintao
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 53 : 202 - 208
  • [23] A study of the hydrodynamic characteristics of a vertical water wall in a 2953t/h ultra-supercritical pressure boiler
    Zhu, Xiaojing
    Wang, Weishu
    Xu, Weihui
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 86 : 404 - 414
  • [24] Dynamic analysis for ultra-supercritical boiler water wall considering uneven heat flux distribution and combustion instability
    Wang, Chao
    Chen, Xiangru
    Liu, Bin
    Liu, Kairui
    Han, Yuan
    Wang, Limin
    Che, Defu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 236
  • [25] Analysis and Precautionary measures for T23 Steel Water Wall Leakage of 1000MW Ultra-supercritical Tower Boiler
    Li Fang-yong
    Zhan Zhi-gang
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2531 - 2536
  • [26] Application of PCA-GBRT/RF model for predicting heat flux on boiler water-cooled wall
    Yang, Jiahui
    Jiang, Chongjun
    Li, Ruiyu
    Sun, Yi
    An, Hong
    Deng, Lei
    Che, Defu
    APPLIED THERMAL ENGINEERING, 2025, 273
  • [27] Model-based once-through boiler start-up water wall steam temperature control
    Cheng, X
    Kephart, RW
    Menten, CH
    PROCEEDINGS OF THE 2000 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 2000, : 778 - 783
  • [28] A numerical study of bed expansion in supercritical water fluidized bed with a non-spherical particle drag model
    Lu, Youjun
    Wei, Liping
    Wei, Jinjia
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 104 : 164 - 173
  • [29] Unsteady-state heat transfer characteristics of spiral water wall tube in advanced-ultra-supercritical boilers from experiments and distributed parameter model
    Ge, Xueli
    Zhang, Zhongxiao
    Fan, Haojie
    Zhang, Jian
    Bi, Degui
    ENERGY, 2019, 189