Comparison of flexible ureteroscopes: Deflection, irrigant flow and optical characteristics

被引:51
作者
Abdelshehid, C
Ahlering, MT
Chou, D
Park, HK
Basillote, J
Lee, D
Kim, I
Eichel, L
Protsenko, D
Wong, B
McDougall, E
Clayman, RV
机构
[1] Univ Calif Irvine, Dept Urol, Orange, CA 92868 USA
[2] Univ Calif Irvine, Beckman Laser Inst, Orange, CA 92868 USA
关键词
ureteroscopy; surgical instruments; irrigation; fiber optics;
D O I
10.1097/01.ju.0000158139.65771.0a
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We measured and compared the deflection, irrigation flow rates, distortion, resolution and light transmission of new generation flexible ureteroscopes. Materials and Methods: Multiple characteristics of 5 flexible ureteroscopes (ACMI DUR-8 Elite (TM), Olympus URF-P3 (TM), Storz 11278AU1 (TM) [Flex-X], Wolf 7330.072 (TM) and Wolf 7325.172 (TM)) commonly available in the market were measured and compared. Measured data included active deflection, irrigation flow rates and optical characteristics. Each ureteroscope was evaluated with an empty working channel and with various accessories. Optical characteristics, specifically resolution and distortion, were measured using test targets (Edmund Optics, Barrington, New Jersey). Light transmission was also measured from the ureteroscope tip at 50% and 100% intensity. All 5 flexible ureteroscopes were tested in a laboratory setting using a Storz OR 1 (TM) system to capture the images. Results: For all 5 ureteroscopes the angle of deflection was most impaired by a 365 mu m laser fiber probe and least impaired by a 2.2Fr nitinol basket. Among all 5 ureteroscopes irrigation flow rate was most impaired with a 3.0Fr basket and least impaired with 200 mu m laser fiber. The Wolf 7325.172 had the highest observed resolution of 25.39 lines per mm and the Wolf 7330.072 had the lowest distortion at. 11.9%. The Karl Storz Flex-X and the ACMI DUR-8 Elite had the highest light cutput at 374 and 364 mV, respectively. Conclusions: The various flexible ureteroscopes differ with regard to flow rates as well as degree of deflection with either an empty or an occupied working channel. The Wolf flexible ureteroscope with a slightly larger working channel and a fused quartz bundle provided for superior flow and better optical performance. However, the greatest amount of tip deflection and highest light output were found in the ACMI and Karl Storz flexible ureteroscopes.
引用
收藏
页码:2017 / 2021
页数:5
相关论文
共 10 条
[1]   Flexible ureteroscopes: A single center evaluation of the durability and function of the new endoscopes smaller than 9Fr [J].
Afane, JS ;
Olweny, EO ;
Bercowsky, E ;
Sundaram, CP ;
Dunn, MD ;
Shalhav, AL ;
McDougall, EM ;
Clayman, RV .
JOURNAL OF UROLOGY, 2000, 164 (04) :1164-1168
[2]  
Bagley D H, 1994, Semin Urol, V12, P32
[3]  
Bagley D H, 1987, Surg Endosc, V1, P119, DOI 10.1007/BF00312699
[4]   PERCUTANEOUS ANTEGRADE FLEXIBLE URETEROSCOPY [J].
BAGLEY, DH ;
RITTENBERG, MH .
UROLOGY, 1986, 27 (04) :331-334
[5]   Ureteroscopy: Effect of technology and technique on clinical practice [J].
Chow, GK ;
Patterson, DE ;
Blute, ML ;
Segura, JW .
JOURNAL OF UROLOGY, 2003, 170 (01) :99-102
[6]   Small diameter, actively deflectable, flexible ureteropyeloscopy [J].
Grasso, M ;
Bagley, D .
JOURNAL OF UROLOGY, 1998, 160 (05) :1648-1653
[7]   Evaluation of overall costs of currently available small flexible ureteroscopes [J].
Landman, J ;
Lee, DI ;
Lee, C ;
Monga, M .
UROLOGY, 2003, 62 (02) :218-222
[8]   FIBER OPTICS IN UROLOGY [J].
MARSHALL, VF .
JOURNAL OF UROLOGY, 1964, 91 (01) :110-&
[9]   Flexible ureteroscopes: a user's guide [J].
Parkin, J ;
Keeley, FX ;
Timoney, AG .
BJU INTERNATIONAL, 2002, 90 (07) :640-643
[10]  
TROJAN L, 2003, 18 E U ANN M POST 13