Finite element analysis of locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation

被引:4
|
作者
Yu, Xiao [1 ]
Li, Wei-long [2 ]
Pang, Qing-jiang [1 ]
Zhou, Rong-li [1 ]
机构
[1] Ningbo 2 Hosp, Dept Orthoped, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Univ, Sch Med, Ningbo, Zhejiang, Peoples R China
关键词
Locking plate; 1; 4 tubular plate; tarsometatarsal joint; fracture-dislocation; finite element analysis; BIOMECHANICAL ANALYSIS; ARTHRODESIS; FOOT;
D O I
10.1177/0300060517707114
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective The optimal plate for fixation of tarsometatarsal joint injuries is controversial. The objective of this study was to compare the biomechanical characteristics between a locking plate and 1/4 tubular plate for first tarsometatarsal joint fracture-dislocation. Method Finite element analysis was used after establishment of a first tarsometatarsal joint fracture-dislocation model. Two implant simulations using a locking plate and five-hole 1/4 tubular plate were designed to simulate fixation of the fracture-dislocation. The displacement of the first tarsometatarsal articular surface and the stress distribution in the implants were calculated. Results A 700-N load was applied to both models. The minimum displacement of the articular surface in the locking plate and 1/4 tubular plate model was 0.6471mm and 0.3833mm, respectively. The maximum principal stress in the locking plate and 1/4 tubular plate was 1.212x10(3)MPa and 1.107x10(3)MPa, respectively. Conclusion Use of a 1/4 tubular plate is recommended for fixation of first tarsometatarsal joint fracture-dislocation after consideration of other factors such as economical issues.
引用
收藏
页码:1528 / 1534
页数:7
相关论文
共 50 条
  • [41] A novel percutaneous crossed screws fixation in treatment of Day type II crescent fracture-dislocation: A finite element analysis
    Cai, Leyi
    Zhang, Yingying
    Zheng, Wenhao
    Wang, Jianshun
    Guo, Xiaoshan
    Feng, Yongzeng
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 20 : 37 - 46
  • [42] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Dejan Blažević
    Janoš Kodvanj
    Petra Adamović
    Dinko Vidović
    Zlatko Trobonjača
    Srećko Sabalić
    Journal of Orthopaedic Surgery and Research, 17
  • [43] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Blazevic, Dejan
    Kodvanj, Janos
    Adamovic, Petra
    Vidovic, Dinko
    Trobonjaca, Zlatko
    Sabalic, Srecko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [44] Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis
    Li, Jia
    Yin, Pengbin
    Zhang, Licheng
    Chen, Hua
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 1895 - 1900
  • [45] Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis
    Latifi, Mohammed Hadi
    Ganthel, Kunalan
    Rukmanikanthan, Shanmugam
    Mansor, Azura
    Kamarul, Tunku
    Bilgen, Mehmet
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [46] Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis
    Mohammed Hadi Latifi
    Kunalan Ganthel
    Shanmugam Rukmanikanthan
    Azura Mansor
    Tunku Kamarul
    Mehmet Bilgen
    BioMedical Engineering OnLine, 11
  • [47] Biomechanical Evaluation of an Oblique Lateral Locking Plate System for Oblique Lumbar Interbody Fusion: A Finite Element Analysis
    Wang, Yinge
    Wang, Jiajia
    Tu, Sha
    Li, Shuang
    Yi, Jiangpu
    Zhao, Haien
    Qiao, Huanhuan
    Yan, Kang
    Liao, Bo
    WORLD NEUROSURGERY, 2022, 160 : E126 - E141
  • [48] Biomechanical analysis of a newly designed and 3D printed plate-locking interbody cage: an observational study of finite element analysis
    Ni, Shuai
    Yang, Rui
    Liu, Sanmao
    Hu, Yunxiang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [49] Finite element analysis of mini-plate stabilization of human mandible angle fracture - a comparative study
    Wadolowski, Piotr
    Krzesinski, Grzegorz
    Gutowski, Piotr
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2020, 22 (03) : 105 - 116
  • [50] Vacuum electron beam brazing technology and finite element analysis on temperature field of capillary to plate joint
    芦凤桂
    唐新华
    梁智
    李少青
    姚舜
    China Welding, 2007, (02) : 5 - 10