Effective dose estimation in cone-beam computed tomography for dental use by Monte-Carlo simulation optimizing calculation numbers using a step-and-shoot method

被引:4
|
作者
Ozaki, Yoshihiro [1 ]
Watanabe, Hiroshi [1 ]
Kurabayashi, Tohru [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Oral & Maxillofacial Radiol, Tokyo, Japan
关键词
radiation protection; Radiation Dosimeters; Monte Carlo Method; cone-beam computed tomography; Radiation; Dental; DOSIMETRY;
D O I
10.1259/dmfr.20210084
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The objective of this study was to perform effective dose estimation in cone-beam CT for dental use (CBCT) using a Monte-Carlo simulation employing a step--and--shoot method as well as to determine the optimal number of steps. Methods: We simulated 3DX Accuitomo FPD8 as a CBCT model and estimated the effective doses of a large and a small field of view (FOV) examination against the virtual Rando phantom using a particle and heavy ion transport code system. We confirmed the results compared to those from a thermo-luminescence dosemeter (TLD) system in a real phantom and investigated how the reduced angle calculations could be accepted. Results: The effective doses of both FOVs estimated with each one degree were almost the same as those estimated from the TLD measurements. Considering the effective doses and the itemized organ doses, simulation with 5 degrees and 10 degrees is acceptable for the large and small FOV, respectively. We tried to compare an effective dose with a large FOV as well as with multiple small FOVs covering the corresponding area and found that the effective dose from six small FOVs was approximately 1.2 times higher than that of the large FOVs. Conclusion: We successfully performed a Monte-Carlo simulation using a step-and-shoot method and estimated the effective dose in CBCT. Our findings indicate that simulation with 5 degrees or 10 degrees is acceptable based on the FOV size, while a small multiple FOV scan is recommended from a radiation protection viewpoint.
引用
收藏
页数:9
相关论文
共 32 条
  • [21] Dental age estimation in Indonesian adults: An investigation of the maxillary canine pulp-to-tooth volume ratio using cone-beam computed tomography
    Anjani, Khamila Gayatri
    Boedi, Rizky Merdietio
    Sam, Belly
    Oscandar, Fahmi
    IMAGING SCIENCE IN DENTISTRY, 2023, 53 (03) : 221 - 227
  • [22] Estimation of effective imaging dose and excess absolute risk of secondary cancer incidence for four-dimensional cone-beam computed tomography acquisition
    Yuasa, Yuki
    Shiinoki, Takehiro
    Onizuka, Ryota
    Fujimoto, Koya
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 57 - 68
  • [23] Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality
    Kawauchi, Satoru
    Chida, Koichi
    Moritake, Takashi
    Hamada, Yusuke
    Tsuruta, Wataro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 192 - 199
  • [24] Investigating the effect of dental implant materials with different densities on radiotherapy dose distribution using Monte-Carlo simulation and pencil beam convolution algorithm
    Akyol, Oya
    Dirican, Bahar
    Toklu, Turkay
    Eren, Hakan
    Olgar, Turan
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (04)
  • [25] Estimation of X-ray Energy Spectrum of Cone-Beam Computed Tomography Scanner Using Percentage Depth Dose Measurements and Machine Learning Approach
    Hasegawa, Yu
    Haga, Akihiro
    Sakata, Dousatsu
    Kanazawa, Yuki
    Tominaga, Masahide
    Sasaki, Motoharu
    Imae, Toshikazu
    Nakagawa, Keiichi
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 2021, 90 (07)
  • [26] TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170
    Ernst, Marina
    Manser, Peter
    Dula, Karl
    Volken, Werner
    Stampanoni, Marco F. M.
    Fix, Michael K.
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (07)
  • [27] Monte Carlo-based simulation of virtual 3 and 4-dimensional cone-beam computed tomography from computed tomography images: An end-to-end framework and a deep learning-based speedup strategy
    Madesta, Frederic
    Sentker, Thilo
    Rohling, Clemens
    Gauer, Tobias
    Schmitz, Ruediger
    Werner, Rene
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [28] Quantification of the kV X-ray imaging dose during real-time tumor tracking and from three- and four-dimensional cone-beam computed tomography in lung cancer patients using a Monte Carlo simulation
    Nakamura, Mitsuhiro
    Ishihara, Yoshitomo
    Matsuo, Yukinori
    Iizuka, Yusuke
    Ueki, Nami
    Iramina, Hiraku
    Hirashima, Hideaki
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 173 - 181
  • [29] Diagnostic Accuracy of Cystic Lesions Using a Pre-Programmed Low-Dose and Standard-Dose Dental Cone-Beam Computed Tomography Protocol: An Ex Vivo Comparison Study
    Husain, Adib Al-Haj
    Dobelin, Quirin
    Giacomelli-Hiestand, Barbara
    Wiedemeier, Daniel B.
    Stadlinger, Bernd
    Valdec, Silvio
    SENSORS, 2021, 21 (21)
  • [30] Dose estimation for cone-beam computed tomography in image-guided radiation therapy for pelvic cancer using adult mesh-type reference computational phantoms
    Cumur, Ceyda
    Fujibuchi, Toshioh
    Arakawa, Hiroyuki
    Hamada, Keisuke
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) : 203 - 211