Long-Term Monitoring of Infiltration Trench for Nonpoint Source Pollution Control

被引:36
作者
Maniquiz, Marla C. [1 ]
Lee, So-Young [1 ]
Kim, Lee-Hyung [1 ]
机构
[1] Kongju Natl Univ, Dept Civil & Environm Engn, Disaster Prevent Res Ctr, Cheonan 330717, Chungnamdo, South Korea
关键词
BMP; Infiltration trench; Monitoring; NPS; Stormwater; Urban; STORMWATER RUNOFF; LOADS; AREA;
D O I
10.1007/s11270-009-0318-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nonpoint source pollution management initiated by the Ministry of Environment (MOE) in Korea resulted to the construction of 25 pilot facilities termed Best Management Practices (BMPs) until 2005. The national nonpoint sources control projects were employed to fulfill the Total Maximum Daily Load programs. The long-term monitoring being conducted at the sites which began in 2006 is providing detailed insight into the performance of the BMPs. The experience and performance data will be used to better understand and implement similar structural BMPs in the future as well as to assist the MOE in developing the design and maintenance guidelines of BMPs. This study presents the results gathered from the monitoring field tests and experiments over 22 rainfall events between the June 2006 and September 2008 period investigating the pollutant removal efficiency of the infiltration trench BMP that is one of the 25 pilot projects of the MOE. In addition, it includes the development of simple linear regression models to estimate constituent event mean concentration. The results reveal high treatment efficiencies for total suspended solids (89%); biochemical oxygen demand, chemical oxygen demand, and dissolved organic carbon (89-93%); oil and grease (100%); cadmium, lead, and zinc (89-93%); total nitrogen (84%); and total phosphorus (82%). The monitoring data and results will represent a step forward to a better prediction of impacts in the environment and to the national development of BMPs for sustainable watershed management in the country.
引用
收藏
页码:13 / 26
页数:14
相关论文
共 22 条
[1]   Modified rational method for sizing infiltration structures [J].
Akan, AO .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (04) :539-542
[2]   Infiltration pond design for highway runoff treatment in semiarid climates [J].
Barbosa, AE ;
Hvitved-Jacobsen, T .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2001, 127 (11) :1014-1022
[3]   Analysis and predictive models of stormwater runoff volumes, loads, and pollutant concentrations from watersheds in the Twin Cities metropolitan area, Minnesota, USA [J].
Brezonik, PL ;
Stadelmann, TH .
WATER RESEARCH, 2002, 36 (07) :1743-1757
[4]   Evaluation of methods for estimating stormwater pollutant loads [J].
Charbeneau, RJ ;
Barrett, ME .
WATER ENVIRONMENT RESEARCH, 1998, 70 (07) :1295-1302
[5]  
CHILSON M, 2004, THESIS FLORIDA ATLAN
[6]  
DRIVER N E., 1990, U.S. Geological Survey Water Supply. Papper 2363
[7]  
DUCHENE M, 1992, WATER RESOUR BULL, V28, P517
[8]   Water quality characteristics of storm water from major land uses in South Florida [J].
Graves, GA ;
Wan, YS ;
Fike, DL .
JOURNAL OF THE AMERICAN WATER RESOURCES ASSOCIATION, 2004, 40 (06) :1405-1419
[9]   Characteristics of highway stormwater runoff [J].
Han, Younghan ;
Lau, Sim-Lin ;
Kayhanian, Masoud ;
Stenstrom, Michael K. .
WATER ENVIRONMENT RESEARCH, 2006, 78 (12) :2377-2388
[10]  
HARRINGTON BW, 1989, P URB RUN WAT QUAL C