Ultrasound-guided intravenous catheter survival impacted by amount of catheter residing in the vein

被引:48
作者
Pandurangadu, Ananda Vishnu [1 ]
Tucker, Jared [1 ]
Brackney, Abigail R. [1 ]
Bahl, Amit [1 ]
机构
[1] Oakland Univ, William Beaumont Sch Med, Dept Emergency Med, Beaumont Hlth Syst, Royal Oak, MI 48309 USA
关键词
ULTRASONOGRAPHY; COMPLICATIONS; CANNULATION; PREVENTION; THERAPY; FAILURE; ACCESS;
D O I
10.1136/emermed-2017-206803
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective Ultrasound (US)-guided peripheral IVs have a high failure rate. We explore the relationship between the quantity of catheter residing within the vein and the functionality of the catheter over time. Methods This was a prospective, observational single-site study. Adult ED patients with US-guided IVs had the catheter visualised under ultrasound post-placement. IV placement time and catheter length residing in the vein was obtained. Exclusions included catheter not visualised, patient discharged from ED unless IV failed, <24 hour hospitalisation unless IV failed or patient self-removed IV. Inpatient follow-up occurred within 24, 48 and 72 hours from the IV placement time. Catheter functionality was noted. If the catheter failed, the time and reason for failure was documented. Results 113 patients were enrolled; 27 were excluded. Of the 86 study subjects, 29 (33.7%) patients' IVs failed and 57 (66.3%) remained functional. Median time to IV failure was 15.6 hours. 100% of IVs failed when <30% of the catheter was in the vein; 32.4% of IVs failed when 30%-64% of the catheter was in the vein; no IVs failed when >= 65% of the catheter was in the vein (p<0.0002). The HR was 0.71 (95% CI 0.60 to 0.83), and for every 5% increase of catheter in vein, the hazard of the IV failing decreases by 29% (p<0.0001). Conclusion The quantity of catheter residing in the vein is a key predictor of long-term functionality of US-guided IVs and is strongly associated with the hazard of failure within 72 hours. Catheter failure is high when <30% of the catheter resided in the vein. Optimum catheter survival occurs when >= 65% of the catheter is placed in the vein.
引用
收藏
页码:550 / 555
页数:6
相关论文
共 20 条
  • [1] [Anonymous], POLICIES PROCEDURES
  • [2] A randomized controlled trial assessing the use of ultrasound for nurse-performed IV placement in difficult access ED patients
    Bahl, Amit
    Pandurangadu, Ananda Vishnu
    Tucker, Jared
    Bagan, Michael
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (10) : 1950 - 1954
  • [3] Is routine replacement of peripheral intravenous catheters necessary?
    Bregenzer, T
    Conen, D
    Sakmann, P
    Widmer, AF
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (02) : 151 - 156
  • [4] Power failure: why small sample size undermines the reliability of neuroscience
    Button, Katherine S.
    Ioannidis, John P. A.
    Mokrysz, Claire
    Nosek, Brian A.
    Flint, Jonathan
    Robinson, Emma S. J.
    Munafo, Marcus R.
    [J]. NATURE REVIEWS NEUROSCIENCE, 2013, 14 (05) : 365 - 376
  • [5] Catney M R, 2001, J Infus Nurs, V24, P332, DOI 10.1097/00129804-200109000-00008
  • [6] Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access
    Costantino, TG
    Parikh, AK
    Satz, WA
    Fojtik, JP
    [J]. ANNALS OF EMERGENCY MEDICINE, 2005, 46 (05) : 456 - 461
  • [7] Ultrasonography-guided peripheral intravenous catheter survival in ED patients with difficult access
    Dargin, James M.
    Rebholz, Casey M.
    Lowenstein, Robert A.
    Mitchell, Patricia M.
    Feldman, James A.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (01) : 1 - 7
  • [8] Intravenous Therapy A Review of Complications and Economic Considerations of Peripheral Access
    Dychter, Samuel S.
    Gold, David A.
    Carson, Deborah
    Haller, Michael
    [J]. JOURNAL OF INFUSION NURSING, 2012, 35 (02) : 84 - 91
  • [9] Standard-length catheters vs long catheters in ultrasound-guided peripheral vein cannulation
    Elia, Fabrizio
    Ferrari, Giovanni
    Molino, Paola
    Converso, Marcella
    De Filippi, Giovanna
    Milan, Alberto
    Apra, Franco
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (05) : 712 - 716
  • [10] The effect of vessel depth, diameter, and location on ultrasound-guided peripheral intravenous catheter longevity
    Fields, J. Matthew
    Dean, Anthony J.
    Todman, Raleigh W.
    Au, Arthur K.
    Anderson, Kenton L.
    Ku, Bon S.
    Pines, Jesse M.
    Panebianco, Nova L.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (07) : 1134 - 1140