An exploration of equivalent scenarios for building facade fire standard tests

被引:19
作者
Li, Yizhou [1 ]
Wang, Zilong [1 ]
Huang, Xinyan [1 ]
机构
[1] Hong Kong Polytech Univ, Res Ctr Fire Safety Engn, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 52卷
关键词
Fire simulation; Spilled flame; Facade fire tests; Heat release rate; Heat flux; FULL-SCALE; BEHAVIOR; COMPARTMENT; SYSTEMS;
D O I
10.1016/j.jobe.2022.104399
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The building facade system is a key part of green buildings and carbon neutrality, but its fire safety is a global problem. Many large-scale facade fire standard tests are created to evaluate the fire risk of facade systems, but they are different from country to country, and their test results are difficult to compare. This study simulates five scenario-based facade fire standard tests, BS 8414-1 (UK), GB/T 29416 (China), ISO 13785-2, NFPA 285 (USA), and JIS A 1310 (Japan). Simulations explore the heat flux and temperature of spilled facade fire plume that controls the ignition and flame spread of facade fire. Under the default fire scenario, the BS 8414-1 and GB/T 29416 generate the largest heat flux (~100 kW/m(2)) to ignite the facade above the opening. The facade fire plume in ISO 13785-2 produces a near-constant heat flux (~50 kW/m(2)) for 2 m above the opening. The heat flux and plume temperature of NFPA 285 largely depend on the extra window burner, and JIS A 1310 can produce intensive heating on the facade by increasing the chamber fire heat release rate (HRR). The heat flux and temperature of spilled plume increase almost linearly with the outdoor fire HRR. Thus, by adjusting the total fire HRR, the values of facade surface heat flux, plume temperature, and ignition height can be matched to enable a fair comparison among different tests. This unique numerical work explores the equivalent facade fire scenarios for different standard tests that can guide future facade fire test development and optimization.
引用
收藏
页数:13
相关论文
共 42 条
  • [1] Fire performance evaluation of cladding wall assemblies using the 16-ft high parallel panel test method of ANSI/FM 4880
    Agarwal, Gaurav
    Wang, Yi
    Dorofeev, Sergey
    [J]. FIRE AND MATERIALS, 2021, 45 (05) : 609 - 623
  • [2] Modeling of fire exposure in facade fire testing
    Anderson, J.
    Bostroem, L.
    McNamee, R. Jansson
    Milovanovic, B.
    [J]. FIRE AND MATERIALS, 2018, 42 (05) : 475 - 483
  • [3] Anderson J., 2020, FIRE MATER
  • [4] [Anonymous], 2002, 1378522002 ISO
  • [5] [Anonymous], 2020, 84141 BS
  • [6] [Anonymous], 2019, 2852019 NFPA
  • [7] Aschehoug I, 2008, STATE OF THE ART REV
  • [8] Facade fire tests: Towards an international test standard
    Babrauskas, V
    [J]. FIRE TECHNOLOGY, 1996, 32 (03) : 219 - 230
  • [9] Bonner M., 2018, International Journal of High-Rise Buildings, V7, P363, DOI DOI 10.21022/IJHRB.2018.7.4.363
  • [10] KRESNIK: A top-down, statistical approach to understand the fire performance of building facades using standard test data
    Bonner, Matthew
    Wegrzynski, Wojciech
    Papis, Bartlomiej K.
    Rein, Guillermo
    [J]. BUILDING AND ENVIRONMENT, 2020, 169