Preparation and chromatographic application of macroporous silicate in a capillary

被引:22
作者
Ishizuka, N [1 ]
Nakanishi, K
Hirao, K
Tanaka, N
机构
[1] Kyoto Univ, Grad Sch Engn, Dept Chem Mat, Sakyo Ku, Kyoto 6068501, Japan
[2] Kyoto Inst Technol, Dept Polymer Sci & Engn, Sakyo Ku, Kyoto 6068585, Japan
关键词
phase separation; silica; capillary column; HPLC; CEC;
D O I
10.1023/A:1008770707572
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Continuous macroporous silica gel networks were prepared in a fused silica capillary, and evaluated in reversed-phase liquid chromatography. Under pressure-driven conditions, considerable dependence of column efficiency on the linear velocity of the mobile phase was observed in spite of the small size of the silica skeletons. A major source of band broadening in the pressure-driven mode was found in the A-term of van Deemter equation. The performance of the continuous silica capillary column in the electro-driven mode was much better than that in the pressure-driven mode.
引用
收藏
页码:371 / 375
页数:5
相关论文
共 14 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   SilicaROD™ -: A new challenge in fast high-performance liquid chromatography separations [J].
Cabrera, K ;
Wieland, G ;
Lubda, D ;
Nakanishi, K ;
Soga, N ;
Minakuchi, H ;
Unger, KK .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (01) :50-53
[3]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[4]  
Horvath C, 1980, HIGH PERFORMANCE LIQ, V2, P1
[5]  
Ishizuka N, 1998, HRC-J HIGH RES CHROM, V21, P477
[6]   Designing monolithic double-pore silica for high-speed liquid chromatography [J].
Ishizuka, N ;
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :133-137
[7]   Ultrahigh pressure reversed-phase capillary liquid chromatography:: Isocratic and gradient elution using columns packed with 1.0-μm particles [J].
MacNair, JE ;
Patel, KD ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :700-708
[8]   Octadecylsilylated porous silica rods as separation media for reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3498-3501
[9]   Effect of domain size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1998, 797 (1-2) :121-131
[10]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146