Biomechanical comparison of anatomical plating systems for comminuted distal humeral fractures

被引:22
|
作者
Varady, Patrick A. [1 ,2 ]
von Rueden, Christian [1 ,2 ,3 ]
Greinwald, Markus [1 ,2 ]
Hungerer, Sven [1 ,2 ,3 ]
Paetzold, Robert [1 ,2 ,3 ]
Augat, Peter [1 ,2 ]
机构
[1] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
[2] Trauma Ctr Murnau, Inst Biomech, Prof Kuntscher Str 8, D-82418 Murnau, Germany
[3] Trauma Ctr Murnau, Dept Trauma Surg, Prof Kuntscher Str 8, D-82418 Murnau, Germany
关键词
Anatomical poly-axial plate; Distal humeral fracture; Failuremechanism; Fatigue limit; Systemstiffness; FIXATION; PARALLEL; LOCKING; CONFIGURATIONS; FORCES; JOINT;
D O I
10.1007/s00264-017-3444-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Six different mono-axial and poly-axial distal humeral plating systems with an anatomical plate design were compared. The aim of the biomechanical tests was to examine differences regarding system stiffness, median fatigue limit, and failure mechanisms. Method Different configurations of two double plate fixation systems by two manufacturers for the treatment of complex distal humeral fractures (AO/OTA type C2.3) were biomechanically tested in a physiologically relevant setup. Result The 180A degrees Stryker configuration presented itself as the system with the highest stiffness, being significantly stiffer (p < 0.001) than every system other than the poly-axial 180A degrees aap system (p = 0.378). For the median fatigue limit the 180A degrees Stryker and poly-axial aap systems were ranked first and second. The failure mechanism for all 90A degrees systems was a fatigue breakage of the posterolateral plate. The 180A degrees aap systems demonstrated breakage of the most distal screws of the lateral plate. The 180A degrees Stryker system demonstrated screw breakage on both the medial and lateral plates. Discussion Breakage of the posterolateral plate as a failure mechanism for the 90A degrees systems was expected. The 180A degrees systems demonstrated a higher stiffness compared to the 90A degrees constructs for the axial loading. In conclusion, both poly-axial anatomical plating systems provide sufficient stability in this scenario, and the 180A degrees configurations demonstrated superior stiffness.
引用
收藏
页码:1709 / 1714
页数:6
相关论文
共 50 条
  • [41] Dual Plating of Distal Femoral Fractures
    Thorne, Tyler J.
    Nelson, Chase T.
    Lisitano, Leonard S. J.
    Higgins, Thomas F.
    Rothberg, David L.
    Haller, Justin M.
    Marchand, Lucas S.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2024, 14 (02):
  • [42] DVR plating of distal radius fractures
    Vanhaecke, J.
    Fernandez, D. L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S33 - S36
  • [43] Investigating the effect of distal screw and peg length on stability in volar plating of comminuted, intra-articular distal radius fractures in a cadaveric model
    Zeng, Francine
    Nayak, Raghunandan
    Megalla, Martinus
    Pasha, Mehreen
    Bari, Shiza
    Liu, Dashun
    Ferreira, Joel V.
    Parrino, Anthony
    Rodner, Craig M.
    CLINICAL BIOMECHANICS, 2025, 124
  • [44] Biomechanical comparison of composite and cadaveric humeri models in experiments on operated humeral shaft fractures
    Melvin, Patricia R.
    Wheatley, Benjamin M.
    Schimoler, Patrick J.
    Kharlamov, Alexander
    Miller, Mark C.
    Elias, John J.
    Altman, Gregory T.
    JOURNAL OF BIOMECHANICS, 2024, 165
  • [45] A paradigm shift in the surgical reconstruction of extra-articular distal humeral fractures: Single-column plating
    Meloy, Gregory M.
    Mormino, Matthew A.
    Siska, Peter A.
    Tarkin, Ivan S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (11): : 1620 - 1624
  • [46] Nonunion of distal humeral fractures: Current concepts
    De Crescenzo, Angelo
    Garofalo, Raffaele
    Bartoli, Matteo
    Pederzini, Luigi Adriano
    Celli, Andrea
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2024, 9 (05)
  • [47] Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length
    Liu, Xiong
    Wu, Wei-dong
    Fang, Ya-feng
    Zhang, Mei-chao
    Huang, Wen-hua
    PLOS ONE, 2014, 9 (07):
  • [48] Effect of Screw Length in Volar Plating for Intra-Articular Distal Radius Fractures: A Biomechanical Study
    Hong, Thomas S.
    Lee, Daniel J.
    Jahani, Babak
    Broz, Kaitlyn S.
    Aboytes, Donald A.
    Tang, Simon
    Demartini, Stephen
    Brogan, David M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (12): : 1186 - 1195
  • [49] Volar Fixed-Angle Plating of Distal Radius Fractures: Screws Versus Pegs-A Biomechanical Study in a Cadaveric Model
    Mehling, Isabella
    Klitscher, Daniela
    Mehling, Andreas P.
    Nowak, Tobias E.
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (07) : 395 - 401
  • [50] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360