Biomechanical comparison of anatomical plating systems for comminuted distal humeral fractures

被引:22
|
作者
Varady, Patrick A. [1 ,2 ]
von Rueden, Christian [1 ,2 ,3 ]
Greinwald, Markus [1 ,2 ]
Hungerer, Sven [1 ,2 ,3 ]
Paetzold, Robert [1 ,2 ,3 ]
Augat, Peter [1 ,2 ]
机构
[1] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
[2] Trauma Ctr Murnau, Inst Biomech, Prof Kuntscher Str 8, D-82418 Murnau, Germany
[3] Trauma Ctr Murnau, Dept Trauma Surg, Prof Kuntscher Str 8, D-82418 Murnau, Germany
关键词
Anatomical poly-axial plate; Distal humeral fracture; Failuremechanism; Fatigue limit; Systemstiffness; FIXATION; PARALLEL; LOCKING; CONFIGURATIONS; FORCES; JOINT;
D O I
10.1007/s00264-017-3444-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Six different mono-axial and poly-axial distal humeral plating systems with an anatomical plate design were compared. The aim of the biomechanical tests was to examine differences regarding system stiffness, median fatigue limit, and failure mechanisms. Method Different configurations of two double plate fixation systems by two manufacturers for the treatment of complex distal humeral fractures (AO/OTA type C2.3) were biomechanically tested in a physiologically relevant setup. Result The 180A degrees Stryker configuration presented itself as the system with the highest stiffness, being significantly stiffer (p < 0.001) than every system other than the poly-axial 180A degrees aap system (p = 0.378). For the median fatigue limit the 180A degrees Stryker and poly-axial aap systems were ranked first and second. The failure mechanism for all 90A degrees systems was a fatigue breakage of the posterolateral plate. The 180A degrees aap systems demonstrated breakage of the most distal screws of the lateral plate. The 180A degrees Stryker system demonstrated screw breakage on both the medial and lateral plates. Discussion Breakage of the posterolateral plate as a failure mechanism for the 90A degrees systems was expected. The 180A degrees systems demonstrated a higher stiffness compared to the 90A degrees constructs for the axial loading. In conclusion, both poly-axial anatomical plating systems provide sufficient stability in this scenario, and the 180A degrees configurations demonstrated superior stiffness.
引用
收藏
页码:1709 / 1714
页数:6
相关论文
共 50 条
  • [31] Management of distal humeral fractures in the elderly
    Strauss, Eric J.
    Alaia, Michael
    Egol, Kenneth A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 : 10 - 16
  • [32] The Kudo humeral component as primary hemiarthroplasty in distal humeral fractures
    Adolfsson, Lars
    Nestorson, Jens
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (04) : 451 - 455
  • [33] Anterior minimally invasive plating osteosynthesis using reversed proximal humeral internal locking system plate for distal humeral shaft fractures
    Jitprapaikulsarn, Surasak
    Neti, Nutdanai
    Thremthakanpon, Witoon
    Gromprasit, Arthit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08) : 1515 - 1521
  • [34] Contradictory working length effects in locked plating of the distal and middle femoral fractures a biomechanical study
    Chao, Ching-Kong
    Chen, You-Lin
    Wu, Jian-Ming
    Lin, Chen-Huei
    Chuang, Ting-Yu
    Lin, Jinn
    CLINICAL BIOMECHANICS, 2020, 80
  • [35] Anterolateral Versus Medial Plating of Distal Extra-articular Tibia Fractures: A Biomechanical Model
    Pirolo, Joseph M.
    Behn, Anthony W.
    Abrams, Geoffrey D.
    Bishop, Julius A.
    ORTHOPEDICS, 2015, 38 (09) : E760 - E765
  • [36] Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior Stability? A Comparative Biomechanical In Vitro Study
    Mehling, Isabella
    Schmidt-Horlohe, Kay
    Mueller, Lars Peter
    Sternstein, Werner
    Korner, Jan
    Rommens, Pol Maria
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 581 - 587
  • [37] Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures
    Katthagen, Jan Christoph
    Schwarze, Michael
    Meyer-Kobbe, Josefin
    Voigt, Christine
    Hurschler, Christof
    Lill, Helmut
    CLINICAL BIOMECHANICS, 2014, 29 (07) : 735 - 741
  • [38] Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration
    Windolf, Markus
    Maza, Edgardo Ramos
    Gueorguiev, Boyko
    Braunstein, Volker
    Schwieger, Karsten
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [39] Treatment of Comminuted Talar Neck Fractures With Use of Minifragment Plating
    Maceroli, Michael A.
    Wong, Christopher
    Sanders, Roy W.
    Ketz, John P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (10) : 572 - 578
  • [40] Overdrilling increases the risk of screw perforation in locked plating of complex proximal humeral fractures - A biomechanical cadaveric study
    Burkhard, Benjamin
    Schopper, Clemens
    Ciric, Daniel
    Mischler, Dominic
    Gueorguiev, Boyko
    Varga, Peter
    JOURNAL OF BIOMECHANICS, 2021, 117