Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report

被引:132
|
作者
Ramoa, Carolina P. [1 ,2 ]
Hiler, Marzena M. [1 ,2 ]
Spindle, Tory R. [1 ,2 ]
Lopez, Alexa A. [1 ,2 ]
Karaoghlanian, Nareg [4 ]
Lipato, Thokozeni [1 ,3 ]
Breland, Alison B. [1 ,2 ]
Shihadeh, Alan [1 ,4 ]
Eissenberg, Thomas [1 ,2 ]
机构
[1] Virginia Commonwealth Univ, Ctr Study Tobacco Prod, Med Coll Virginia Campus, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Dept Psychol, Med Coll Virginia Campus, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Dept Internal Med, Med Coll Virginia Campus, Richmond, VA 23298 USA
[4] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
基金
美国国家卫生研究院;
关键词
USER PUFF TOPOGRAPHY; DEVICE; ADULTS; MODEL;
D O I
10.1136/tobaccocontrol-2015-052447
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Introduction Electronic cigarettes (ECIGs) aerosolise a liquid that usually contains propylene glycol and/or vegetable glycerine, flavourants and the dependence-producing drug, nicotine, in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration and plasma nicotine concentration and puffing behaviour in experienced ECIG users. Methods Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil 'cartomiser' loaded with 1 mL of a flavoured propylene glycol/vegetable glycerine liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18 or 36 mg/mL). In each session, participants completed two 10-puff ECIG-use bouts (30 s puff interval) separated by 60 min. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume and average flow rate were measured. Results Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/mL (SD=7.7) for 0 mg/mL liquid, with significantly (p<0.05) higher mean concentrations observed for the 8 (mean=17.8 ng/mL, SD=14.6), 18 (mean=25.9 ng/mL, SD=17.5) and 36 mg/mL (mean=30.2 ng/mL; SD=20.0) concentrations; a similar pattern was observed for bout 2. For bout 1, at 36 mg/mL, the mean post-minus pre-bout difference was 24.1 ng/mL (SD=18.3). Puff topography data were consistent with previous results and revealed few reliable differences across conditions. Discussion This study demonstrates a relationship between ECIG liquid nicotine concentration and user plasma nicotine concentration in experienced ECIG users. Nicotine delivery from some ECIGs may exceed that of a combustible cigarette. The rationale for this higher level of nicotine delivery is uncertain.
引用
收藏
页码:E6 / E9
页数:4
相关论文
共 50 条
  • [31] Assessment of the abuse liability of three menthol Vuse Solo electronic cigarettes relative to combustible cigarettes and nicotine gum
    Mitchell F. Stiles
    Leanne R. Campbell
    Tao Jin
    Donald W. Graff
    Reginald V. Fant
    Jack E. Henningfield
    Psychopharmacology, 2018, 235 : 2077 - 2086
  • [32] Abuse liability of two electronic nicotine delivery systems compared with combustible cigarettes and nicotine gum from an open-label randomized crossover study
    Campbell, Chris
    Jin, Tao
    Round, Elaine K.
    Nelson, Paul R.
    Baxter, Sarah
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [33] Abuse liability of two electronic nicotine delivery systems compared with combustible cigarettes and nicotine gum from an open-label randomized crossover study
    Chris Campbell
    Tao Jin
    Elaine K. Round
    Paul R. Nelson
    Sarah Baxter
    Scientific Reports, 13
  • [34] Acute effects of using an electronic nicotine-delivery device (electronic cigarette) on myocardial function: comparison with the effects of regular cigarettes
    Konstantinos E Farsalinos
    Dimitris Tsiapras
    Stamatis Kyrzopoulos
    Maria Savvopoulou
    Vassilis Voudris
    BMC Cardiovascular Disorders, 14
  • [35] Acute effects of using an electronic nicotine-delivery device (electronic cigarette) on myocardial function: comparison with the effects of regular cigarettes
    Farsalinos, Konstantinos E.
    Tsiapras, Dimitris
    Kyrzopoulos, Stamatis
    Savvopoulou, Maria
    Voudris, Vassilis
    BMC CARDIOVASCULAR DISORDERS, 2014, 14
  • [36] The Effects of Combustible Cigarettes and Electronic Nicotine Delivery Systems on Immune Cell-Driven Inflammation and Mucosal Healing in Ulcerative Colitis
    Kastratovic, Nikolina
    Markovic, Vladimir
    Arsenijevic, Aleksandar
    Volarevic, Ana
    Zdravkovic, Natasa
    Zdravkovic, Marija
    Brankovic, Marija
    Gmizic, Tijana
    Harrell, Carl Randall
    Jakovljevic, Vladimir
    Djonov, Valentin
    Volarevic, Vladislav
    NICOTINE & TOBACCO RESEARCH, 2024,
  • [37] Electronic Cigarettes: Effective Nicotine Delivery After Acute Administration
    Vansickel, Andrea Rae
    Eissenberg, Thomas
    NICOTINE & TOBACCO RESEARCH, 2013, 15 (01) : 267 - 270
  • [38] E -Cigarettes and Other Electronic Nicotine Delivery Systems (ENDS)
    Brown, Amy
    Balk, Sophie J.
    CURRENT PROBLEMS IN PEDIATRIC AND ADOLESCENT HEALTH CARE, 2020, 50 (02)
  • [39] Nicotine delivery, retention and pharmacokinetics from various electronic cigarettes
    Helen, Gideon St.
    Havel, Christopher
    Dempsey, Delia A.
    Jacob, Peyton, III
    Benowitz, Neal L.
    ADDICTION, 2016, 111 (03) : 535 - 544
  • [40] Perceived Comparative Harm of Cigarettes and Electronic Nicotine Delivery Systems
    Nyman, Amy L.
    Huang, Jidong
    Weaver, Scott R.
    Eriksen, Michael P.
    JAMA NETWORK OPEN, 2019, 2 (11) : e1915680