Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report

被引:132
|
作者
Ramoa, Carolina P. [1 ,2 ]
Hiler, Marzena M. [1 ,2 ]
Spindle, Tory R. [1 ,2 ]
Lopez, Alexa A. [1 ,2 ]
Karaoghlanian, Nareg [4 ]
Lipato, Thokozeni [1 ,3 ]
Breland, Alison B. [1 ,2 ]
Shihadeh, Alan [1 ,4 ]
Eissenberg, Thomas [1 ,2 ]
机构
[1] Virginia Commonwealth Univ, Ctr Study Tobacco Prod, Med Coll Virginia Campus, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Dept Psychol, Med Coll Virginia Campus, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Dept Internal Med, Med Coll Virginia Campus, Richmond, VA 23298 USA
[4] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
基金
美国国家卫生研究院;
关键词
USER PUFF TOPOGRAPHY; DEVICE; ADULTS; MODEL;
D O I
10.1136/tobaccocontrol-2015-052447
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Introduction Electronic cigarettes (ECIGs) aerosolise a liquid that usually contains propylene glycol and/or vegetable glycerine, flavourants and the dependence-producing drug, nicotine, in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration and plasma nicotine concentration and puffing behaviour in experienced ECIG users. Methods Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil 'cartomiser' loaded with 1 mL of a flavoured propylene glycol/vegetable glycerine liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18 or 36 mg/mL). In each session, participants completed two 10-puff ECIG-use bouts (30 s puff interval) separated by 60 min. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume and average flow rate were measured. Results Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/mL (SD=7.7) for 0 mg/mL liquid, with significantly (p<0.05) higher mean concentrations observed for the 8 (mean=17.8 ng/mL, SD=14.6), 18 (mean=25.9 ng/mL, SD=17.5) and 36 mg/mL (mean=30.2 ng/mL; SD=20.0) concentrations; a similar pattern was observed for bout 2. For bout 1, at 36 mg/mL, the mean post-minus pre-bout difference was 24.1 ng/mL (SD=18.3). Puff topography data were consistent with previous results and revealed few reliable differences across conditions. Discussion This study demonstrates a relationship between ECIG liquid nicotine concentration and user plasma nicotine concentration in experienced ECIG users. Nicotine delivery from some ECIGs may exceed that of a combustible cigarette. The rationale for this higher level of nicotine delivery is uncertain.
引用
收藏
页码:E6 / E9
页数:4
相关论文
共 50 条
  • [21] Position statement on electronic cigarettes or electronic nicotine delivery systems
    Bam, T. S.
    Bellew, W.
    Berezhnova, I.
    Jackson-Morris, A.
    Jones, A.
    Latif, E.
    Molinari, M. A.
    Quan, G.
    Singh, R. J.
    Wisotzky, M.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2014, 18 (01) : 5 - 7
  • [22] Biomarkers of Exposure for Dual Use of Electronic Cigarettes and Combustible Cigarettes: Nicotelline, NNAL, and Total Nicotine Equivalents
    Jacob, Peyton, III
    St Helen, Gideon
    Yu, Lisa
    Nardone, Natalie
    Havel, Christopher
    Cheung, Polly
    Benowitz, Neal L.
    NICOTINE & TOBACCO RESEARCH, 2020, 22 (07) : 1107 - 1113
  • [23] Cardiovascular and Pulmonary Responses to Acute Use of Electronic Nicotine Delivery Systems and Combustible Cigarettes in Long-Term Users
    Tattersall, Matthew C.
    Hughey, Christina M.
    Piasecki, Thomas M.
    Korcarz, Claudia E.
    Hansen, Kristin M.
    Ott, Nancy R.
    Sandbo, Nathan
    Fiore, Michael C.
    Baker, Timothy B.
    Stein, James H.
    CHEST, 2023, 164 (03) : 757 - 769
  • [24] Effects of Electronic Cigarette Liquid Nicotine Concentration on Plasma Nicotine and Puff Topography in Tobacco Cigarette Smokers: A Preliminary Report
    Lopez, Alexa A.
    Hiler, Marzena M.
    Soule, Eric K.
    Ramoa, Carolina P.
    Karaoghlanian, Nareg V.
    Lipato, Thokozeni
    Breland, Alison B.
    Shihadeh, Alan L.
    Eissenberg, Thomas
    NICOTINE & TOBACCO RESEARCH, 2016, 18 (05) : 720 - 723
  • [25] Part one: abuse liability of Vuse Solo (G2) electronic nicotine delivery system relative to combustible cigarettes and nicotine gum
    Chris Campbell
    Tao Jin
    Elaine K. Round
    Eckhardt Schmidt
    Paul Nelson
    Sarah Baxter
    Scientific Reports, 12 (1)
  • [26] Electronic cigarettes: the new face of nicotine delivery and addiction
    Alexander, Laura E. Crotty
    Vyas, Anuja
    Schraufnagel, Dean E.
    Malhotra, Atul
    JOURNAL OF THORACIC DISEASE, 2015, 7 (08) : E248 - E251
  • [27] Part one: abuse liability of Vuse Solo (G2) electronic nicotine delivery system relative to combustible cigarettes and nicotine gum
    Campbell, Chris
    Jin, Tao
    Round, Elaine K.
    Schmidt, Eckhardt
    Nelson, Paul
    Baxter, Sarah
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [28] Y Abuse liability assessment of the JUUL system in two nicotine concentrations compared to combustible cigarette, nicotine gum and comparator electronic nicotine delivery system
    Goldenson, Nicholas, I
    Buchhalter, August R.
    Augustson, Erik M.
    Rubinstein, Mark L.
    Van Hoof, Dennis
    Henningfield, Jack E.
    DRUG AND ALCOHOL DEPENDENCE, 2020, 217
  • [29] Assessment of the abuse liability of three menthol Vuse Solo electronic cigarettes relative to combustible cigarettes and nicotine gum
    Stiles, Mitchell F.
    Campbell, Leanne R.
    Jin, Tao
    Graff, Donald W.
    Fant, Reginald V.
    Henningfield, Jack E.
    PSYCHOPHARMACOLOGY, 2018, 235 (07) : 2077 - 2086
  • [30] Differences in nicotine intake and effects from electronic and combustible cigarettes among dual users
    St Helen, Gideon
    Nardone, Natalie
    Addo, Newton
    Dempsey, Delia
    Havel, Christopher
    Jacob, Peyton, III
    Benowitz, Neal L.
    ADDICTION, 2020, 115 (04) : 757 - 767