Electronic cigarette nicotine delivery can exceed that of combustible cigarettes: a preliminary report

被引:133
作者
Ramoa, Carolina P. [1 ,2 ]
Hiler, Marzena M. [1 ,2 ]
Spindle, Tory R. [1 ,2 ]
Lopez, Alexa A. [1 ,2 ]
Karaoghlanian, Nareg [4 ]
Lipato, Thokozeni [1 ,3 ]
Breland, Alison B. [1 ,2 ]
Shihadeh, Alan [1 ,4 ]
Eissenberg, Thomas [1 ,2 ]
机构
[1] Virginia Commonwealth Univ, Ctr Study Tobacco Prod, Med Coll Virginia Campus, Richmond, VA 23298 USA
[2] Virginia Commonwealth Univ, Dept Psychol, Med Coll Virginia Campus, Richmond, VA 23298 USA
[3] Virginia Commonwealth Univ, Dept Internal Med, Med Coll Virginia Campus, Richmond, VA 23298 USA
[4] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
基金
美国国家卫生研究院;
关键词
USER PUFF TOPOGRAPHY; DEVICE; ADULTS; MODEL;
D O I
10.1136/tobaccocontrol-2015-052447
中图分类号
R194 [卫生标准、卫生检查、医药管理];
学科分类号
摘要
Introduction Electronic cigarettes (ECIGs) aerosolise a liquid that usually contains propylene glycol and/or vegetable glycerine, flavourants and the dependence-producing drug, nicotine, in various concentrations. This laboratory study examined the relationship between liquid nicotine concentration and plasma nicotine concentration and puffing behaviour in experienced ECIG users. Methods Sixteen ECIG-experienced participants used a 3.3-Volt ECIG battery attached to a 1.5-Ohm dual-coil 'cartomiser' loaded with 1 mL of a flavoured propylene glycol/vegetable glycerine liquid to complete four sessions, at least 2 days apart, that differed by nicotine concentration (0, 8, 18 or 36 mg/mL). In each session, participants completed two 10-puff ECIG-use bouts (30 s puff interval) separated by 60 min. Venous blood was sampled to determine plasma nicotine concentration. Puff duration, volume and average flow rate were measured. Results Immediately after bout 1, mean plasma nicotine concentration was 5.5 ng/mL (SD=7.7) for 0 mg/mL liquid, with significantly (p<0.05) higher mean concentrations observed for the 8 (mean=17.8 ng/mL, SD=14.6), 18 (mean=25.9 ng/mL, SD=17.5) and 36 mg/mL (mean=30.2 ng/mL; SD=20.0) concentrations; a similar pattern was observed for bout 2. For bout 1, at 36 mg/mL, the mean post-minus pre-bout difference was 24.1 ng/mL (SD=18.3). Puff topography data were consistent with previous results and revealed few reliable differences across conditions. Discussion This study demonstrates a relationship between ECIG liquid nicotine concentration and user plasma nicotine concentration in experienced ECIG users. Nicotine delivery from some ECIGs may exceed that of a combustible cigarette. The rationale for this higher level of nicotine delivery is uncertain.
引用
收藏
页码:E6 / E9
页数:4
相关论文
共 18 条
[1]  
[Anonymous], 1991, Design and analysis: A researcher's handbook
[2]   Puffing Topography and Nicotine Intake of Electronic Cigarette Users [J].
Behar, Rachel Z. ;
Hua, My ;
Talbot, Prue .
PLOS ONE, 2015, 10 (02)
[3]   Clinical laboratory evaluation of potential reduced exposure products for smokers [J].
Breland, Alison B. ;
Kleykamp, Bethea A. ;
Eissenberg, Thomas .
NICOTINE & TOBACCO RESEARCH, 2006, 8 (06) :727-738
[4]   Effect of an electronic nicotine delivery device (e cigarette) on desire to smoke and withdrawal, user preferences and nicotine delivery: randomised cross-over trial [J].
Bullen, C. ;
McRobbie, H. ;
Thornley, S. ;
Glover, M. ;
Lin, R. ;
Laugesen, M. .
TOBACCO CONTROL, 2010, 19 (02) :98-103
[5]   Intentions to Smoke Cigarettes Among Never-Smoking US Middle and High School Electronic Cigarette Users: National Youth Tobacco Survey, 2011-2013 [J].
Bunnell, Rebecca E. ;
Agaku, Israel T. ;
Arrazola, Rene A. ;
Apelberg, Benjamin J. ;
Caraballo, Ralph S. ;
Corey, Catherine G. ;
Coleman, Blair N. ;
Dube, Shanta R. ;
King, Brian A. .
NICOTINE & TOBACCO RESEARCH, 2015, 17 (02) :228-235
[6]   Nicotine absorption from electronic cigarette use: comparison between first and new-generation devices [J].
Farsalinos, Konstantinos E. ;
Spyrou, Alketa ;
Tsimopoulou, Kalliroi ;
Stefopoulos, Christos ;
Romagna, Giorgio ;
Voudris, Vassilis .
SCIENTIFIC REPORTS, 2014, 4
[7]   Evaluation of Electronic Cigarette Use (Vaping) Topography and Estimation of Liquid Consumption: Implications for Research Protocol Standards Definition and for Public Health Authorities' Regulation [J].
Farsalinos, Konstantinos E. ;
Romagna, Giorgio ;
Tsiapras, Dimitris ;
Kyrzopoulos, Stamatis ;
Voudris, Vassilis .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2013, 10 (06) :2500-2514
[8]   A Longitudinal Analysis of Electronic Cigarette Use and Smoking Cessation [J].
Grana, Rachel A. ;
Popova, Lucy ;
Ling, Pamela M. .
JAMA INTERNAL MEDICINE, 2014, 174 (05) :812-813
[9]   Mining data on usage of electronic nicotine delivery systems (ENDS) from YouTube videos [J].
Hua, My ;
Yip, Henry ;
Talbot, Prue .
TOBACCO CONTROL, 2013, 22 (02) :103-106
[10]   Awareness and Ever-Use of Electronic Cigarettes Among U.S. Adults, 2010-2011 [J].
King, Brian A. ;
Alam, Suhana ;
Promoff, Gabbi ;
Arrazola, Rene ;
Dube, Shanta R. .
NICOTINE & TOBACCO RESEARCH, 2013, 15 (09) :1623-1627