Focused ion beam time-of-flight secondary ion mass spectroscopy tomography of through-silicon vias for 3D integration

被引:4
|
作者
Barnes, Jean-Paul [1 ,2 ]
Djomeni, Larissa [1 ,2 ]
Minoret, Stephane [1 ,2 ]
Mourier, Thierry [1 ,2 ]
Fabbri, Jean-Marc [1 ,2 ]
Audoit, Guillaume [1 ,2 ]
Fadloun, Sabrina [3 ]
机构
[1] Univ Grenoble Alpes, F-38000 Grenoble, France
[2] CEA Grenoble, LETI, MINATEC Campus, F-38054 Grenoble, France
[3] SPTS Technol, Inovallee Bat B,445 Rue Lavoisier, F-38330 Montbonnot St Martin, France
来源
关键词
DIFFUSION; TIN;
D O I
10.1116/1.4947463
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two important issues for the integration of through-silicon via (TSV) interconnects are whether the TSVs are completely filled with Cu and whether unwanted Cu diffusion occurs. To address these issues, specific analysis protocols were developed using custom TSV geometry, sample preparation, and time-of-flight secondary ion mass spectrometry (TOF-SIMS) analysis. To obtain three-dimensional (3D) information on the filling of the Cu TSV, an in situ Ga focused ion beam (FIB) was used to cut the TSVs, after which a TOF-SIMS image was acquired and a 3D volume was thereby acquired using a slice-and-view approach. In this way, voids in the TSVs were observed, and defects in the barrier layer were identified. To analyze Cu diffusion, a special square cross-section TSV geometry was used. A protocol was developed to allow depth profiling of TSVs using precise wafer cleaving followed by an ex situ plasma FIB cut that left the sidewalls of the TSVs covered with only a thin SiO2 layer. Dual-beam depth profiling was then used on the cleaved and FIB-polished side of the sample which was placed flat in the sample holder. Several TSVs were simultaneously depth-profiled, and the diffusion profiles of copper were analyzed at different TSV depths. (C) 2016 American Vacuum Society.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Electrical Investigation of Cu Pumping in Through-Silicon Vias for BEOL Reliability in 3D Integration
    Cheng, Chuan-An
    Sugie, Ryuichi
    Uchida, Tomoyuki
    Chen, Kou-Hua
    Chiu, Chi-Tsung
    Chen, Kuan-Neng
    2015 INTERNATIONAL 3D SYSTEMS INTEGRATION CONFERENCE (3DIC 2015), 2015,
  • [32] EXPLORING LITHIUM-ION INTENSITY AND DISTRIBUTION VIA A TIME-OF-FLIGHT SECONDARY ION MASS SPECTROSCOPY
    ChiuHuang, Cheng-Kai
    Zhou, Chuanzhen
    Huang, Hsiao-Ying Shadow
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 10, 2014,
  • [33] Ga-focused ion beam time-of-flight secondary ion mass spectrometer analysis of the grain boundary segregation/precipitation of boron in steel
    Tanaka, Tomohito
    Fujishiro, Taishi
    Shigesato, Genichi
    Hayashi, Shun-ichi
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (05) : 297 - 300
  • [34] A Silicon Platform With Through-Silicon Vias for Heterogeneous RF 3D Modules
    Bar, Pierre
    Joblot, Sylvain
    Coudrain, Perceval
    Carpentier, Jean-Francois
    Reig, Bruno
    Fuchs, Christine
    Ferrandon, Christine
    Charbonnier, Jean
    Sibuet, Henri
    2011 6TH EUROPEAN MICROWAVE INTEGRATED CIRCUIT CONFERENCE, 2011, : 612 - 615
  • [35] A Silicon Platform With Through-Silicon Vias for Heterogeneous RF 3D Modules
    Bar, Pierre
    Joblot, Sylvain
    Coudrain, Perceval
    Carpentier, Jean-Francois
    Reig, Bruno
    Fuchs, Christine
    Ferrandon, Christine
    Charbonnier, Jean
    Sibuet, Henri
    2011 41ST EUROPEAN MICROWAVE CONFERENCE, 2011, : 1173 - 1176
  • [36] Fabrication of 3D charged particle trap using through-silicon vias etched by deep reactive ion etching
    Verma, Ankita
    Jennings, Joshah
    Johnson, Ryan D.
    Weber, Marc H.
    Lynn, Kelvin G.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2013, 31 (03):
  • [37] A new focused ion beam optical system for a time-of-flight-secondary ion mass spectrometry instrument
    Central Research Laboratory, Hitachi Ltd., Kokubunji, Tokyo, 185, Japan
    RAPID COMMUN. MASS SPECTROM., 2 (175-178):
  • [38] A new focused ion beam optical system for a time-of-flight-secondary ion mass spectrometry instrument
    Shichi, H
    Osabe, S
    Kanehori, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (02) : 175 - 178
  • [39] Thermomechanical Reliability Challenges For 3D Interconnects With Through-Silicon Vias
    Ryu, Suk-Kyu
    Lu, Kuan-Hsun
    Zhang, Xuefeng
    Im, Jay
    Ho, Paul S.
    Huang, Rui
    STRESS-INDUCED PHENOMENA IN METALLIZATION, 2010, 1300 : 189 - +
  • [40] Time-of-Flight Secondary Ion Mass Spectrometry Profiling for Arsenic in Silicon Dioxide Matrix
    Teo, Han Wei
    Wang, Yun
    Mo, Zhi Qiang
    Zhao, Si Ping
    Proceedings of the 2016 IEEE 23rd International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA), 2016, : 109 - 111