Noninvasive iPhone Measurement of Left Ventricular Ejection Fraction Using Intrinsic Frequency Methodology

被引:32
作者
Pahlevan, Niema M. [1 ,2 ]
Rinderknecht, Derek G. [3 ]
Tavallali, Peyman [3 ,4 ]
Razavi, Marianne [3 ,5 ]
Tran, Thao T. [2 ]
Fong, Michael W. [6 ]
Kloner, Robert A. [6 ,7 ]
Csete, Marie [2 ,5 ,8 ]
Gharib, Morteza [5 ,9 ]
机构
[1] Univ Southern Calif, Dept Aerosp & Mech Engn, Los Angeles, CA 90007 USA
[2] Huntington Med Res Inst, Adv Imaging & Spect Ctr, Pasadena, CA 91101 USA
[3] Avicena LLC, Los Angeles, CA USA
[4] CALTECH, Comp & Math Sci, Pasadena, CA 91125 USA
[5] CALTECH, Med Engn Dept, Pasadena, CA 91125 USA
[6] Univ Southern Calif, Keck Sch Med, Div Cardiovasc Med, Los Angeles, CA USA
[7] Huntington Med Res Inst, Cardiovasc Res Inst, Pasadena, CA USA
[8] Univ Southern Calif, Keck Sch Med, Dept Anesthesiol, Los Angeles, CA USA
[9] CALTECH, Grad Aerosp Lab, Pasadena, CA 91125 USA
关键词
cardiac MRI; ejection fraction; heart failure; intrinsic frequency; noninvasive smartphone diagnostics; PRESSURE WAVE-FORM; TRANSTHORACIC ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; CARDIAC-OUTPUT; CINEVENTRICULOGRAPHY;
D O I
10.1097/CCM.0000000000002459
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The study is based on previously reported mathematical analysis of arterial waveform that extracts hidden oscillations in the waveform that we called intrinsic frequencies. The goal of this clinical study was to compare the accuracy of left ventricular ejection fraction derived from intrinsic frequencies noninvasively versus left ventricular ejection fraction obtained with cardiac MRI, the most accurate method for left ventricular ejection fraction measurement. Design: After informed consent, in one visit, subjects underwent cardiac MRI examination and noninvasive capture of a carotid waveform using an iPhone camera (The waveform is captured using a custom app that constructs the waveform from skin displacement images during the cardiac cycle.). The waveform was analyzed using intrinsic frequency algorithm. Setting: Outpatient MRI facility. Subjects: Adults able to undergo MRI were referred by local physicians or self-referred in response to local advertisement and included patients with heart failure with reduced ejection fraction diagnosed by a cardiologist. Interventions: Standard cardiac MRI sequences were used, with periodic breath holding for image stabilization. To minimize motion artifact, the iPhone camera was held in a cradle over the carotid artery during iPhone measurements. Measurements and Main Results: Regardless of neck morphology, carotid waveforms were captured in all subjects, within seconds to minutes. Seventy-two patients were studied, ranging in age from 20 to 92 years old. The main endpoint of analysis was left ventricular ejection fraction; overall, the correlation between ejection fraction-iPhone and ejection fraction-MRI was 0.74 (r = 0.74; p < 0.0001; ejection fraction-MRI = 0.93 x [ejection fraction-iPhone] + 1.9). Conclusions: Analysis of carotid waveforms using intrinsic frequency methods can be used to document left ventricular ejection fraction with accuracy comparable with that of MRI. The measurements require no training to perform or interpret, no calibration, and can be repeated at the bedside to generate almost continuous analysis of left ventricular ejection fraction without arterial cannulation.
引用
收藏
页码:1115 / 1120
页数:6
相关论文
共 17 条
  • [1] Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of models
    Cerutti, C
    Gustin, MP
    Molino, P
    Paultre, CZ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (03): : H1148 - H1155
  • [2] Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography -: Comparison with magnetic resonance imaging
    Dewey, Marc
    Mueller, Mira
    Eddicks, Stephan
    Schnapauff, Dirk
    Teige, Florian
    Rutsch, Wolfgang
    Borges, Adrian C.
    Hamm, Bernd
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 2034 - 2044
  • [3] Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography Comparison With Magnetic Resonance Imaging as the Reference Standard
    Greupner, Johannes
    Zimmermann, Elke
    Grohmann, Andrea
    Duebel, Hans-Peter
    Althoff, Till
    Borges, Adrian C.
    Rutsch, Wolfgang
    Schlattmann, Peter
    Hamm, Bernd
    Dewey, Marc
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (21) : 1897 - 1907
  • [4] Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography
    Hoffmann, R
    von Bardeleben, S
    ten Cate, F
    Borges, AC
    Kasprzak, J
    Firschke, C
    Lafitte, S
    Al-Saadi, N
    Kuntz-Hehner, S
    Engelhardt, M
    Becher, H
    Vanoverschelde, JL
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (06) : 607 - 616
  • [5] Analysis of Left Ventricular Volumes and Function: A Multicenter Comparison of Cardiac Magnetic Resonance Imaging, Cine Ventriculography, and Unenhanced and Contrast-Enhanced Two-Dimensional and Three-Dimensional Echocardiography
    Hoffmann, Rainer
    Barletta, Giuseppe
    von Bardeleben, Stephan
    Vanoverschelde, Jean Louis
    Kasprzak, Jaroslaw
    Greis, Christian
    Becher, Harald
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 292 - 301
  • [6] Hosenpud J D., 2007, Congestive heart failure
  • [7] Kloner RA, 1984, GUIDE CARDIOLOGY
  • [8] CRITICAL-REVIEW OF SYSTOLIC-TIME INTERVALS
    LEWIS, RP
    RITTGERS, SE
    FORESTER, WF
    BOUDOULAS, H
    [J]. CIRCULATION, 1977, 56 (02) : 146 - 158
  • [9] Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis
    Mukkamala, Ramakrishna
    Xu, Da
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2010, 299 (03): : H584 - H599
  • [10] Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients
    Paarmann, H.
    Groesdonk, H. V.
    Sedemund-Adib, B.
    Hanke, T.
    Heinze, H.
    Heringlake, M.
    Schoen, J.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (04) : 475 - 481