Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty

被引:11
作者
Stone, Andrea H. [1 ]
Sibia, Udai S. [1 ]
MacDonald, James H. [1 ]
机构
[1] Anne Arundel Med Ctr, Annapolis, MD USA
关键词
patient-specific instrumentation; Knee Society Scores; total knee arthroplasty; mechanical alignment; blood loss; MATCHED INSTRUMENTATION; ALIGNMENT; STANDARD; TRIAL;
D O I
10.1177/1553350618787074
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Patient-specific instruments (PSIs) were developed to improve mechanical axis alignment for patients undergoing total knee arthroplasty (TKA) as neutral alignment (180 degrees) is a predictor of long-term success. This study examines alignment accuracy and functional outcomes of PSI as compared with standard instruments (SIs). Methods. We retrospectively reviewed a consecutive series of TKA procedures using PSI. A total of 85 PSI procedures were identified, and these were compared with a matched cohort of 85 TKAs using SI. Intraoperative decision-making, estimated blood loss, efficiency, Knee Society Scores, and postoperative radiographs were evaluated. Results. One hundred and seventy patients with comparable patient demographics were reviewed. Eighty-one percent of the PSI procedures were within target (180 +/- 3 degrees) mechanical alignment, while the SI group had 70% of cases within the target plane (P = .132). Mean target alignment (2.0 degrees PSI vs 2.2 degrees SI, P = .477) was similar between groups. Twenty-seven percent of patients in the PSI group had surgeon-directed intraoperative recuts to improve the perceived coronal alignment. The change in hematocrit was reduced in the PSI group (8.89 vs 7.21, P = .000). Procedure time and total operating room time were equivalent. Knee Society Scores did not differ between groups at 6 months or at 1 year. Conclusion. Patient-specific instrumentation decreased change in hematocrit, though coronal alignment and efficiency were equivalent between groups. Surgeons must evaluate cuts intraoperatively to confirm alignment. Functional outcomes are equivalent for PSI and SI groups.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 24 条
[1]  
[Anonymous], COMPR CAR JOINT REPL
[2]  
Ast Michael P, 2012, Orthop Clin North Am, V43, pe17, DOI 10.1016/j.ocl.2012.07.004
[3]   Preliminary experience with the patient-specific templating total knee arthroplasty 40 cases compared with a matched control group [J].
Boonen, Bert ;
Schotanus, Martijn G. M. ;
Kort, Nanne P. .
ACTA ORTHOPAEDICA, 2012, 83 (04) :387-393
[4]   Setting Value-Based Payment Goals - HHS Efforts to Improve US Health Care [J].
Burwell, Sylvia M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (10) :897-899
[5]   Evaluation of the accuracy of a patient-specific instrumentation by navigation [J].
Conteduca, Fabio ;
Iorio, Raffaele ;
Mazza, Daniele ;
Caperna, Ludovico ;
Bolle, Gabriele ;
Argento, Giuseppe ;
Ferretti, Andrea .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2194-2199
[6]   A comparison of conventional and patient-specific instruments in total knee arthroplasty [J].
Daniilidis, Kiriakos ;
Tibesku, Carsten O. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) :503-508
[7]   A randomised controlled trial of kinematically and mechanically aligned total knee replacements TWO-YEAR CLINICAL RESULTS [J].
Dossett, H. G. ;
Estrada, N. A. ;
Swartz, G. J. ;
LeFevre, G. W. ;
Kwasman, B. G. .
BONE & JOINT JOURNAL, 2014, 96B (07) :907-913
[8]   Coronal Alignment in Total Knee Arthroplasty Just How Important is it? [J].
Fang, David M. ;
Ritter, Merrill A. ;
Davis, Kenneth E. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :39-43
[9]   Does Patient-Specific Instrumentations Improve Short-Term Functional Outcomes After Total Knee Arthroplasty? A Systematic Review and Meta-Analysis [J].
Goyal, Tarun ;
Tripathy, Sujit K. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (10) :2173-2180
[10]   Patient-Specific Instrumentation Does Not Shorten Surgical Time: A Prospective, Randomized Trial [J].
Hamilton, William G. ;
Parks, Nancy L. ;
Saxena, Arjun .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :96-100