摘要
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC), direct current (DC) positive polar (+), and DC negative polar (-) power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3-, SO42-, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction point would be formed, which would seriously reduce the dielectric strength of room temperature vulcanized silicone rubber.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Degradation of Silicone Rubber under AC or DC Voltages in Radiation Environment
    Rajini, V.
    Udayakumar, K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (03) : 834 - 841
  • [42] Surface Charge Decay on HTV Silicone Rubber: Effect of Material Treatment by Corona Discharges
    Kumara, Sarath
    Ma, Bin
    Serdyuk, Yuriy V.
    Gubanski, Stanislaw M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 2189 - 2195
  • [43] Increasing the surface hydrophobicity of silicone rubber by electron beam irradiation in the presence of a glycerol layer
    Sheng, Keyan
    Dong, Xiaohan
    Chen, Zhiyan
    Zhou, Zijian
    Gu, Yanlong
    Huang, Jiang
    APPLIED SURFACE SCIENCE, 2022, 591
  • [44] Suppression of Surface Charge on Micro- and Nano-structured Superhydrophobic Silicone Rubber
    Yan, Zhipeng
    Liang, Xidong
    Cotton, Ian
    Emersic, Christopher
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (03) : 1095 - 1102
  • [45] RTV silicone rubber surface modification for cell biocompatibility by negative-ion implantation
    Zheng, Chenlong
    Wang, Guangfu
    Chu, Yingjie
    Xu, Ya
    Qiu, Menglin
    Xu, Mi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 370 : 73 - 78
  • [46] The role of outgassing in surface flashover under vacuum
    Neuber, AA
    Butcher, M
    Krompholz, H
    Hatfield, LL
    Kristiansen, M
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2000, 28 (05) : 1593 - 1598
  • [47] Effect of mineral oil on flashover voltage of HTV silicone rubber under AC corona ageing: from the view of trap level distribution
    Yu, Yu
    Wang, Ke
    Yang, Yan
    Li, Gang
    Wu, Guangning
    Li, Jinzhong
    Gao, Bo
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (23) : 5498 - 5504
  • [48] Particle size distribution characteristics of naturally polluted insulators under the fog-haze environment
    Tu, Youping
    Sun, Youfei
    Peng, Qingjun
    Wang, Cong
    Gong, Bo
    Chen, Xianfu
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (11): : 3318 - 3326
  • [49] Degradation of Various Polymeric Materials in Clean and Salt Fog Conditions: Measurements of AC Flashover Voltage and Assessment of Surface Damages
    Douar, M. A.
    Beroual, A.
    Souche, X.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 391 - 399
  • [50] Distribution of Polymer Surface Charge under DC Voltage and its Influence on Surface Flashover Characteristics
    Xie, Qing
    Liang, Shaodong
    Fu, Kexin
    Liu, Lizhen
    Huang, He
    Lu, Fangcheng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2157 - 2168