Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze-Fog Environment

被引:12
作者
Ren, Ang [1 ,2 ]
Liu, Hongshun [1 ,2 ]
Wei, Jianchun [1 ,2 ]
Li, Qingquan [1 ,2 ]
机构
[1] Shandong Univ, Dept Elect Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Prov Key Lab UHV Transmiss Technol & Equ, 17923 Jingshi Rd, Jinan 250061, Shandong, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 10期
关键词
haze-fog; natural contamination; surface flashover; silicone rubber; insulators; INSULATORS; AEROSOL; CHINA;
D O I
10.3390/en10101580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC), direct current (DC) positive polar (+), and DC negative polar (-) power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3-, SO42-, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction point would be formed, which would seriously reduce the dielectric strength of room temperature vulcanized silicone rubber.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Research on Flashover Characteristics and Charge Evolution Mechanism of Silicone Rubber Under Different Temperature and Pressure
    Xu, Fengyuan
    Zhang, Liankang
    Feng, Hao
    Li, Guochang
    Zhu, Yuanwei
    Wei, Yanhui
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2025, 14 (02)
  • [32] Charging Mechanism of Surface Flashover on Polyimide Under Electron Beam Irradiation
    Pan, Shaoming
    Su, Yi
    Rao, Xiajin
    Huang, Wei
    Zhao, Jian
    Zhang, Wei
    Han, Fangyuan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (12) : 4919 - 4926
  • [33] Effects of Natural Contamination Components on the Surface Conductivity under Saturated Moisture
    Wang, Liming
    Cao, Bin
    Mei, Hongwei
    Zhao, Chenlong
    Guan, Zhicheng
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (05) : 2945 - 2951
  • [34] Surface analysis of asymmetrically aged 400 kV silicone rubber composite insulators
    Xiong, Y.
    Rowland, S. M.
    Robertson, J.
    Day, R. J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (03) : 763 - 770
  • [35] Trap and Carrier Transport of Pristine and Aged Silicone Rubber by Surface Potential Measurements
    Kang, Wenbin
    Yan, Chenyu
    Li, Shijun
    Huang, Yin
    Min, Daomin
    Li, Shengtao
    2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 207 - 210
  • [36] Surface Potential Dynamics and Flashover Resistance Evaluation of Epoxy Resin Under DC Flashover
    Fan, Lu
    Yin, Yi
    Wang, Yalin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) : 575 - 582
  • [37] The DC Surface Flashover Performance Research of Polyimide Under Low-Energy Electron Irradiation Environment
    Liu, Chenyang
    Zheng, Ying
    Yang, Pei
    Zheng, Xiaoquan
    Li, Ying
    Bian, Enlong
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (01) : 85 - 92
  • [38] Influence of Silicone Rubber Coating on the Characteristics of Surface Streamer Discharge
    Meng, Xiaobo
    Wang, Liming
    Mei, Hongwei
    Zhang, Chuyan
    POLYMERS, 2021, 13 (21)
  • [39] Surface Degradation of HTV Silicone Rubber under the effect of low air Pressure
    Banerjee, Srijib
    Prasad, Shakthi D.
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 307 - 310
  • [40] Corona Aging Characteristics of Silicone Rubber with Different Proportions under Haze Condition
    Bi M.
    Yang Z.
    Jiang T.
    Hu X.
    Pan A.
    Dong Y.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (12): : 167 - 175